ICP DAS USA M-7018Z-G/S - 10 Channel Voltage & Current Thermocouple Input Data Acquisition Module, High Over Voltage Protection & Cable User manual

Type
User manual
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
1
I-7017, I-7018, I-7019, M-7017,
M-7018 and M-7019 Series
User Manual
Warranty
All products manufactured by ICP DAS are under
warranty regarding defective materials for a period of one
year from the date of delivery to the original purchaser.
Warning
ICP DAS assumes no liability for damages resulting
from the use of this product. ICP DAS reserves the right
to change this manual at any time without notification.
The information furnished by ICP DAS is believed to be
accurate and reliable. However, no responsibility is
assumed by ICP DAS for its use, or for any infringements
of patents or other rights of third parties resulting from its
use.
Copyright
Copyright 1999 - 2013 ICP DAS. All rights reserved.
Trademark
The names used for identification only may be
registered trademarks of their respective companies.
Date: 2017/11/07
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
2
Table of Contents
1. Introduction ............................................................................................... 6
1.1 More Information ............................................................................. 9
1.2 Terminal Assignment ..................................................................... 10
1.3 Specifications ................................................................................. 18
1.4 Block Diagrams .............................................................................. 24
1.4.1 Block diagram for the I-7017, I-7017F, and M-7017 .......... 24
1.4.2 Block diagram for the I-7017C, I-7017FC and M-7017C ... 24
1.4.3 Block diagram for the I-7017R and M-7017R ..................... 25
1.4.4 Block diagram for the I-7017R-A5 and M-7017R-A5 ....... 25
1.4.5 Block diagram for the I-7017Z and M-7017Z ..................... 26
1.4.6 Block diagram for the M-7017RMS .................................... 26
1.4.7 Block diagram for the I-7018, I-7018P and M-7018 .......... 27
1.4.8 Block diagram for the I-7018BL .......................................... 27
1.4.9 Block diagram for the I-7018R and M-7018R ..................... 28
1.4.10 Block diagram for the I-7018Z and M-7018Z ................... 28
1.4.11 Block diagram for the M-7018-16 ..................................... 29
1.4.12 Block diagram for the I-7019R and M-7019R ................... 29
1.4.13 Block diagram for the M-7019Z ........................................ 30
1.5 Dimensions ..................................................................................... 31
1.5.1 Modules without Frame Ground .......................................... 31
1.5.2 Modules with Frame Ground ............................................... 32
1.5.3 M-7018-16 ............................................................................ 33
1. 6 Wiring Diagrams ........................................................................... 34
1.6.1 Wiring diagram for the I-7017, I-7017F, I-7017R, M-7017
and M-7017R ......................................................................... 34
1.6.2 Wiring diagram for the I-7017C, I-7017FC, I-7017RC, M-
7017C and M-7017RC .......................................................... 35
1.6.3 Wiring diagram for the I-7017R-A5 and M-7017R-A5 ...... 35
1.6.4 Wiring diagram for the I-7017Z and M-7017Z .................... 35
1.6.5 Wiring diagram for the M-7017RMS ................................... 35
1.6.6 Wiring diagram for the I-7018, I-7018P, I-7018BL, I-7018R,
I-7018Z, M-7018, M-7018R and M-7018Z .......................... 36
1.6.7 Wiring diagram for the M-7018-16 ...................................... 37
1.6.8 Wiring diagram for the I-7019R, M-7019R and M-7019Z .. 37
1.7 Jumper Settings .............................................................................. 38
1.7.1 I-7017, I-7017F, I-7018, I-7018P and I-7018BL Jumper
Settings .................................................................................. 38
1.7.2 I-7019R and M-7019R Jumper Settings............................... 39
1.7.3 M-7019Z Jumper Settings .................................................... 41
1.7.4 I-7017Z and M-7017Z Jumper Settings ............................... 42
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
3
1.8 Quick Start ...................................................................................... 43
1.9 Default Settings .............................................................................. 45
1.10 Calibration .................................................................................... 47
1.11 Configuration Tables .................................................................... 50
1.12 M-7000 Notes ............................................................................... 60
1.12.1 Protocol Switching ............................................................. 60
1.12.2 INIT Mode .......................................................................... 61
1.13 Mounting ...................................................................................... 62
1.13.1 DIN Rail Mounting ............................................................ 62
1.13.2 Piggyback Mounting .......................................................... 64
1.13.3 Wall Mounting.................................................................... 65
1.14 Technical Support......................................................................... 66
2. DCON Protocol ....................................................................................... 67
2.1 %AANNTTCCFF .......................................................................... 71
2.2 #** .................................................................................................. 75
2.3 #AA ................................................................................................ 77
2.4 #AAN, #AANN .............................................................................. 79
2.5 $AA0 .............................................................................................. 81
2.6 $AA1 .............................................................................................. 83
2.7 $AA0Ci........................................................................................... 85
2.8 $AA1Ci........................................................................................... 87
2.9 $AA2 .............................................................................................. 89
2.10 $AA3 ............................................................................................ 91
2.11 $AA4 ............................................................................................ 93
2.12 $AA5VV, $AA5VVVV ............................................................... 95
2.13 $AA6 ............................................................................................ 97
2.14 $AA7CiRrr ................................................................................... 99
2.15 $AA8Ci ...................................................................................... 102
2.16 $AA9 .......................................................................................... 104
2.17 $AA9SNNNN ............................................................................ 106
2.18 $AAA ......................................................................................... 108
2.19 $AAA ......................................................................................... 110
2.20 $AAAi ........................................................................................ 112
2.21 $AAB .......................................................................................... 114
2.22 $AAF .......................................................................................... 116
2.23 $AAM ......................................................................................... 117
2.24 $AAP .......................................................................................... 119
2.25 $AAPN ....................................................................................... 121
2.26 $AAS0 ........................................................................................ 123
2.27 $AAS1 ........................................................................................ 125
2.28 ~AAC ......................................................................................... 127
2.29 ~AACN ....................................................................................... 129
2.30 ~AAEV ....................................................................................... 131
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
4
2.31 ~AAI ........................................................................................... 133
2.32 ~AAO(Name) ............................................................................. 135
2.33 ~AATnn ...................................................................................... 137
2.34 ~** .............................................................................................. 140
2.35 ~AA0 .......................................................................................... 141
2.36 ~AA1 .......................................................................................... 143
2.37 ~AA2 .......................................................................................... 145
2.38 ~AA3EVV .................................................................................. 147
2.39 ~AAEO ....................................................................................... 149
2.40 ~AAEON .................................................................................... 151
2.41 @AAS ........................................................................................ 153
2.42 @AASN ..................................................................................... 155
3. Modbus RTU Protocol .......................................................................... 157
3.1 02 (0x02) Read Input Status ......................................................... 158
3.2 04 (0x04) Read Input Channels .................................................... 159
3.3 70 (0x46) Read/Write Module Settings ....................................... 160
3.3.1 Sub-function 00 (0x00) Read module name ...................... 161
3.3.2 Sub-function 04 (0x04) Set module address ...................... 162
3.3.3 Sub-function 05 (0x05) Read communication settings ...... 163
3.3.4 Sub-function 06 (0x06) Set communication settings ......... 164
3.3.5 Sub-function 07 (0x07) Read type code ............................. 165
3.3.6 Sub-function 08 (0x08) Set type code ................................ 166
3.3.7 Sub-function 32 (0x20) Read firmware version ................. 167
3.3.8 Sub-function 37 (0x25) Read channel enabled/disabled status
............................................................................................. 168
3.3.9 Sub-function 38 (0x26) Set channel enable/disable ........... 169
3.3.10 Sub-function 41 (0x29) Read miscellaneous settings ...... 170
3.3.11 Sub-function 42 (0x2A) Write miscellaneous settings .... 171
3.3.12 Sub-function 43 (0x2B) Read CJC offset ........................ 172
3.3.13 Sub-function 44 (0x2C) Write CJC offset ....................... 173
3.3.14 Sub-function 45 (0x2D) Read CJC enabled/disabled status
............................................................................................. 174
3.3.15 Sub-function 46 (0x2E) Set CJC enable/disable .............. 175
3.3.16 Sub-function 47 (0x2F) Read CJC update setting............ 176
3.3.17 Sub-function 48 (0x30) Write CJC update setting ........... 177
3.4 Address Mappings ........................................................................ 178
3.4.1 M-7017 Series Address Mappings (Base 1) ....................... 178
3.4.2 M-7017RMS Address Mappings (Base 1) ......................... 180
3.4.3 M-7017Z Address Mappings (Base 1) ............................... 182
3.4.4 M-7018 Series Address Mappings (Base 1) ....................... 184
3.4.5 M-7018Z Address Mappings (Base 1) ............................... 186
3.4.6 M-7018-16 Address Mappings (Base 1) ............................ 188
3.4.7 M-7019R Address Mappings (Base 1) ............................... 190
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
5
3.4.8 M-7019Z Address Mappings (Base 1) ............................... 193
3.5 Engineering Data Format Table ................................................... 195
4. Troubleshooting .................................................................................... 197
4.1 Communicating with the module ................................................. 198
4.2 Reading Data ................................................................................ 199
A. Appendix .............................................................................................. 200
A.1 INIT Mode ................................................................................... 200
A.2 Dual Watchdog Operation ........................................................... 202
A.3 Thermocouple .............................................................................. 203
A.4 Frame Ground .............................................................................. 204
A.5 Hexadecimal Data Conversion .................................................... 206
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
6
1. Introduction
The I-7000 series is a family of network data acquisition
and control modules, providing analog-to-digital, digital-
to-analog, digital input/output, timer/counter and other
functions. The modules can be remotely controlled using
a set of commands, which we call the DCON protocol.
Communication between the module and the host is in
ASCII format via an RS-485 bi-directional serial bus
standard. Baud Rates are software programmable and
transmission speeds of up to 115.2K baud can be selected.
The functionality of the M-7000 series is the same as the
I-7000 series, with the exception that the M-7000 series
offers extended support for the Modbus RTU protocol.
Some I-7000 and all M-7000
modules feature a new design
for the frame ground and INIT
switch as shown in the figure
(rear view). The frame ground
provides enhanced static
protection (ESD) abilities and
ensures the module is more
reliable. The INIT switch
allows INIT mode to be
accessed more easily. Refer to
Sections A.1 and A.4 for more
details.
The common features of the I-7017, I-7018 and I-7019 are
as follows:
1. 3000V DC inter-module isolation
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
7
2. 24-bit sigma-delta ADC to provide excellent accuracy
3. Software calibration
The I-7017 is an 8-channel voltage and current input
module. The I-7018 is an 8-channel voltage, current and
thermocouple input module. The I-7019 is an 8-channel
voltage, current, and thermocouple input module, with the
ability to connect various types of inputs to a single
module.
The I-7017 has the following variations:
I-7017F: added support for fast mode, 60
samples/second.
I-7017C: used for current input only, with no external
resistor required.
I-7017FC: used for current input only, with no external
resistor required. Added support for fast mode, 60
samples/second.
I-7017R: added high voltage overload protection,
240Vrms.
I-7017RC: used for current input only, with no external
resistor required. Added high voltage overload
protection, 240Vrms.
I-7017R-A5: used for high voltage input
I-7017Z: 10 channels, added high voltage overload
protection, 240Vrms
M-7017RMS: used for AC input
The I-7018 has the following variations:
M-7018-16: 16 channels, added thermocouple wire
opening detection
I-7018P: added support for two additional
thermocouple types, L and M
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
8
I-7018BL: only support thermocouple types and with
thermocouple wire opening detection
I-7018R: added thermocouple wire opening detection
and high voltage overload protection, 240Vrms
I-7018Z: 10 channels, added thermocouple wire
opening detection and high voltage overload protection,
240Vrms
The I-7019 has the following variation:
I-7019R: added high voltage overload protection,
240Vrms
M-7019Z: 10 channels, added high voltage overload
protection, 240Vrms
The I-7017R, I-7017RC, I-7017Z, I-7018R, I-7018Z,
I-7019R and M-7019Z modules are designed for industrial
plant environments and have special input circuits to
provide 240Vrms continuous overload protection as
shown in the figure.
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
9
1.1 More Information
Refer to chapter 1 of the I-7000 Bus Converter Users
Manual as shown below or visit the ICP DAS website
http://www.icpdas.com for more information regarding the
I-7000 series.
1.1 The I-7000 Series Overview
1.2 Related Documentation for the I-7000 Series
1.3 Common Features of the I-7000 Series
1.4 The I-7000 Series System Network Configuration
1.5 I-7000 Dimensions
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
10
1.2 Terminal Assignment
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
11
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
12
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
13
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
14
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
15
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
16
M-7018-16
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
17
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
18
1.3 Specifications
I-7017F/I-7017R
M-7017R
I-7017C
*3
/I-7017FC/I-7017RC
M-7017C
*3
/M-7017RC
Analog Input
Input Channels
8 differential
*1
8 differential
Input Type
mV, V, mA
*2
mA
Sampling Rate
10 samples/sec (normal)
60 samples/sec (fast)
10 samples/sec (normal)
60 samples/sec (fast)
Bandwidth
15.7Hz (normal)
78.7Hz (fast)
15.7Hz (normal)
78.7Hz (fast)
Accuracy
±0.1% (normal)
±0.5% (fast)
±0.1% (normal)
±0.5% (fast)
Zero Drift
20µV/°C
20µV/°C
Span Drift
25ppm/°C
25ppm/°C
CMR@50/60Hz
86dB min
86dB min
NMR@50/60Hz
100dB min
100dB min
Input Impedance
I-7017R/M-7017R
1MΩ
I-7017F
20MΩ
125Ω
Voltage
overload
Protection
I-7017R/M-7017R
±240V
I-7017F
±120V
I-7017RC/M-7017RC
50mA at 110VDC
I-7017C/FC/M-7017C
50mA at 110VDC
Isolation
3000V DC
3000V DC
Modbus RTU
M-7017R
M-7017C/M-7017RC
Power
Requirement
+10 to +30V DC
+10 to +30V DC
Consumption
1.3W
1.3W
Temperature
Range
Operating
-25°C to +75°C
-25°C to +75°C
Storage
-30°C to +75°C
-30°C to +75°C
*1: For I-7017 and I-7017F, the number of input channels is 8 differential or 6
differential and 2 single-ended by jumper selection.
*2: requires optional external 125 ohm resistor.
*3: I-7017C and M-7017C does not support fast mode, 60 samples/sec sampling rate.
Note: A warm up period of 30 minutes is recommended in order to achieve the complete
performance results described in the specifications.
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
19
I-7017R-A5
M-7017R-A5
I-7017Z
M-7017Z
Analog Input
Input Channels
8 differential
10 differential/20 single-
ended
Input Type
V
mV, V, mA (jumper
selectable)
Sampling Rate
10 samples/sec (normal)
50 samples/sec (fast)
10 samples/sec (normal)
60 samples/sec (fast)
Bandwidth
15.7Hz (normal)
78.7Hz (fast)
15.7Hz (normal)
78.7Hz (fast)
Accuracy
±0.1% (normal)
±0.25% (fast)
±0.1% (normal)
±0.5% (fast)
Zero Drift
20µV/°C
20µV/°C
Span Drift
25ppm/°C
25ppm/°C
CMR@50/60Hz
86dB min
86dB min
NMR@50/60Hz
100dB min
100dB min
Input Impedance
290KΩ
Differential: 2MΩ
Single-ended: 1MΩ
Current
Impedance
125Ω, 1/4W
Voltage overload
Protection
±200V
Differential: ±240V
Single-ended: ±150V
Isolation
3000V DC
3000V DC
Individual
Channel
Configurable
No
Yes
Modbus RTU
M-7017R-A5
M-7017Z
Power
Requirement
+10 to +30V DC
+10 to +30V DC
Consumption
1.7W
2.0W
Temperature
Range
Operating
-25°C to +75°C
-25°C to +75°C
Storage
-30°C to +75°C
-30°C to +75°C
Note: A warm up period of 30 minutes is recommended in order to
achieve the complete performance results described in the
specifications.
I-7017/18/19, M-7017/18/19 User Manual, Rev: B2.6 7MH-020-B26
20
M-7017RMS
Analog Input
Input Channels
8 differential
Input Type
Vrms
Sampling Rate
10 samples/sec
Bandwidth
15.7Hz
Accuracy
Sinusoid:
50/60Hz: ±0.15%
45Hz to 10kHz: ±0.45%
Non-sinusoid:
Crest factor 1 to 2: ±0.2%
Crest factor 2 to 3: ±0.3%
Zero Drift
20µV/°C
Span Drift
25ppm/°C
CMR@50/60Hz
86dB min
NMR@50/60Hz
100dB min
Input Impedance
2MΩ
Voltage overload
Protection
±35V
Isolation
3000V DC
Individual
Channel
Configurable
Yes
Modbus RTU
M-7017RMS
Power
Requirement
+10 to +30V DC
Consumption
0.9W
Temperature
Range
Operating
-25°C to +75°C
Storage
-30°C to +75°C
Note: A warm up period of 30 minutes is recommended in order to
achieve the complete performance results described in the
specifications.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206

ICP DAS USA M-7018Z-G/S - 10 Channel Voltage & Current Thermocouple Input Data Acquisition Module, High Over Voltage Protection & Cable User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI