ADTRAN Total Access 1500 Job Aid

Type
Job Aid
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
For more information, refer to the Installation and Maintenance Practice (P/N 61180408L1-5) available online at www.adtran.com.
Total Access 1500
Quad
R-POTS
P/N: 1180408L1
CLEI: VALIUW0F_ _
Total Access 1500 Quad R-POTS
R-POTS
1180408L1
1
BUSY
2
3
4
*61180408L1-22D*
ports 1-4 use P1-P4 (T/R), respectively. In the 19-inch chassis, physical slots 1-6 use
P1, slots 7-12 use P2, and slots 13-18 use P3.
PROVISIONING
There are no hardware options on the Quad R-POTS access module. The Quad
R-POTS access module is provisioned by connecting a VT100 terminal or a computer
running a terminal emulation program to the craft interface ADMIN port located on the
System Controller Unit (SCU) front panel. Connection to the port is achieved by using
a male-ended RS-232 DB-9 cable. Craft port settings are as follows:
9600 Baud
No Parity
8 Data Bits
1 Stop Bit
No Flow Control
Windows HyperTerminal
Windows HyperTerminal can be used as a VT100 terminal emulation program. Open
HyperTerminal by selecting
Programs/Accessories/HyperTerminal. Refer to the Help
section of HyperTerminal for additional information.
NOTE: To ensure proper display background, select VT100 terminal emulation under
Settings.
Password and User ID
Password protection is a function of the SCU and is factory disabled. If password
authentication is enabled, then the SCU will display the
Logon screen. A valid user
name and password are required to access the menus.
NOTE: The default user name is “user”, and the default password is “password”.
The user name and password are not case sensitive.
Menu Navigation
To traverse through the menus, select the desired entry and press ENTER. To work
backward in the menu press the
ESC key.
The menu tree on the reverse page illustrates the path to every provisioning,
performance, and test access point in the Quad R-POTS menu.
TEST FEATURES
The Quad R-POTS supports a Digital Network Loopback Test, 1004 Hz Tone
Generation Test, Network Hook Test, and Customer Ringing Test for each circuit to
support circuit turnup and maintenance efforts. These tests are initiated from the Total
Access 1500 local craft port on the SCU or remotely via Telnet or SNMP, and are
initiated on an individual port basis. The tests are described below.
DESCRIPTION
The ADTRAN
®
Total Access
®
1500 Quad R-POTS is a Remote Terminal POTS
access module that provides four independent POTS interfaces between a Total Access
1500 Pulse Code Modulation (PCM) backplane and a 2-wire Voice Frequency (VF)
transmission and signaling facility. Each interface contains the necessary circuitry to
convert voice data signals from the customer loop to PCM digital data and convert
PCM digital data from the carrier to voice data. The access module also provides
ringing voltage to the loop when appropriate. The Quad R-POTS features are as
follows:
Four independent VF interfaces
FXS, TR08, PLAR, Tandem, DPO, and TO with SC operating modes
Loop start, Ground start, and Wink start signaling modes
Caller ID Class
compatible
Digital loopback to network
INSTALLATION
After unpacking the Quad R-POTS access module, inspect it for damage. If damage
has occurred, file a claim with the carrier then contact ADTRAN Customer Service.
Refer to the Warranty information on the following page.
The Quad R-POTS inserts into any access module slot (1 through 24, 23-inch chassis
or 1 through 18, 19-inch chassis) of the Total Access 1500 chassis.
Gently, but firmly, push the Quad R-POTS into any slot on the shelf. Simultaneous
thumb pressure at the top and bottom of the Quad R-POTS will ensure a good seat of
the Quad R-POTS pins into the backplane connector. Push the ejector latch up and
closed against the Quad R-POTS front panel to lock it in place.
When the Quad R-POTS first powers up it performs a power up self-test. Once the
power up self-test is complete, the status LEDs will reflect the true state of the
hardware.
FRONT PANEL LEDS
Busy 1-4 ! Off..............On hook
" Green .........Off hook or in test mode
TIME SLOT ASSIGNMENTS
The Total Access 1500 platform can have multiple time slots in the T1 data stream
assigned to each physical slot in the channel bank. The system will automatically map
DS0s in the T1 as determined by the Line Interface Unit (LIU) operational
configuration. Manual mapping is available via the LIU menu.
CONNECTIONS
Four 50-pin male amphenol connectors on the 23-inch Total Access 1500 backplane
and three on the 19-inch chassis backplane provide the interconnect wiring for the four
analog circuits on each access module. For each physical slot on the 23-inch chassis,
61180408L1-22D
0412
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61180408L1-22D
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty
.
Total Access 1500 Quad R-POTS
Digital Network Loopback Test
The Digital Network Loopback test activates a loopback path that takes the DS0 data received from the
network and transmits it back to the network in the appropriate transmit time slot.
1004 Hz Tone Test
The 1004 Hz Tone Generation Test generates a 1004 Hz Digital Reference Signal (DRS) tone toward
the T1 network (0 dBm fixed), toward the customer loop (RX TLP setting), or both directions
simultaneously. While sending the DRS tone toward the customer loop the transmit audio path
(towards the T1 network) will be interrupted.
Network Hook Test
The Network Hook Test forces the AB signaling states towards the T1 network. The bits are set based
upon the operating mode of the channel unit.
Customer Ringing Test
The Customer Ringing Test activates the port’s ring relay in a 2-second on and 4-second off cadence,
providing ringing toward the customers loop.
NOTE: The tests cannot run simultaneously. If a test is in progress and another test is initiated, the
first test will be terminated when the new test starts.
Metallic Test Access
This option is used in conjunction with a List 3 SCU P/N 1180008L3, 1180008L3#S or 1180008L23 to
provide automatic Mechanized Loop Testing (MLT).
COMPLIANCE
The Quad R-POTS complies with the requirements covered under UL 60950 and is intended to be
installed in restricted access areas only and in equipment with a Type “B” or “E” enclosure. The Total
Access 1500 chassis frame ground terminal must be connected to an earth ground to ensure that the
front panel of the Quad R-POTS is properly grounded via the backplane connector.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the users authority to
operate this equipment.
Code Input Output
Power Code C C
Telecommunication Code (TC) X
Installation Code (IC) A
1. Configuration
2. Provisioning
3. Status
Circuit 1-4
4. Test
1. Circuit
2. Digital Network Loopback Test
3. 1004 Hz Tone Test
3. 2-Wire Line Impedence
4. Transmit TLP
Enter Value (-7.0...+9.0)
1. Loop Start
3. TR08 Single Party
2. Ground Start
5. TR08 Auto
4. TR08 Universal VG
7. PLAR D3
6. PLAR D4
9. DPO
8. Tandem
10. FX Ringdown
1. 0.5 seconds
3. 1.5 seconds
2. 1.0 seconds
5. 2.5 seconds
4. 2.0 seconds
7. 3.5 seconds
6. 3.0 seconds
8. 4.0 seconds
1. 250 msec
3. 750 msec
2. 500 msec
5. 2 seconds
4. 1 second
1. Circuit
3. Supervision
2. Conversion Mode
5. Dial Tone Generation
4. Tandem Battery
7. Forward Disconnect Delay
6. Ring Back Tone Generation
9. DNIS Delay
8. DNIS Protocol
1. Circuit 1
3. Circuit 3
2. Circuit 2
4. Circuit 4
1. Circuit 1
3. Circuit 3
2. Circuit 2
4. Circuit 4
1. Circuit 1
3. Circuit 3
2. Circuit 2
4. Circuit 4
1. Inactive
2. Active
1. 600 ohms + 2.16 µF
2. 900 ohms + 2.16 µF
6. Trunk Processing
1. Busy in CFA
Enter Value (0 ... 126)
2. Idle in CFA
1. Immediate Start
2. Wink Start
1. Normal Battery
2. Reverse Battery
1. No Test
3. To Loop
2. To Network
4. To Loop and Network
4. Network Hook Test
1. No Test
3. Off-Hook
2. On-Hook
1. Tandem Inactive
3. Ground Start
2. Loop Start
1. Disabled
3. DNIS Enabled - No Answer
2. DNIS Enabled
5. Customer Ringing Test
1. No Test
2. Ringing
6. Metallic Test Access
1. Inactive
2. Full Split
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
9. Ring Back Tone Generation
9. Tandem Mode Options
Mode
Receive TLP
Transmit TLP
Digital Test
Signal Bits TX/RX
2-Wire Termination
NBOC
On-Hook Messaging
Trunk Processing
Metallic Test
Unit Name
Part Number
CLEI Code
Software Revision
1. Circuit
2. Mode
5. Receive TLP
Enter Value (-9.0...+0.0)
7. On-Hook Messaging
8. NBOC
11. TO w/SC
(2)
(3)
(1)
If Mode = PLAR or FX Ringdown
If Mode = Tandem
(1)
(2)
(3)
If DNIS Protocol = DNIS Enabled or DNIS Enabled - No Answer
  • Page 1 1
  • Page 2 2

ADTRAN Total Access 1500 Job Aid

Type
Job Aid