ESAB Digital Meter Installation guide

Type
Installation guide

This manual is also suitable for

INSTRUCTIONS for
F-15-336
June, 1996
DIGITAL METER WITH PRE-SET MODULE
P/N 36442
for TAF-4 Wire Feeder
INSTALLATION
To prevent accidental electric shock, be sure control cable is dis-
connected from power source or interface box before working in-
side the wire feeder.
1. Make sure control cable is removed from the Power Source or Interface Box.
2. Remove the blank panel from the upper left corner of the front panel of the wire feeder. Retain the screws for
installing option module in step 5.
3. Remove the outer cover of the wire feeder.
4. Install the digital meter option module in the opening where the blank panel was removed. Install the intercon-
necting cable supplied with the option module between P1 of the meter board and P3 of the speed control board
(PCB1). Secure the meter option module with the four screws removed from the blank panel. Refer to Figure 1 for
installed position.
5. Reinstall the outer cover of the wire feeder and reconnect control cable.
SETUP
The meter will read PRE-SET wire speed when not feeding wire and ACTUAL wire speed when feeding wire.
METER DISPLAY PANEL
P/N 32238BK (1)
DIGITAL METER P/N 951042 (1)
STRIP SQ 10—PIN SOCKET
P/N 951176 (1)
DIGITAL METER PC BOARD
P/N 38102 (1)
CONNECT TO
P3 OF
PCB1
P1
Figure 1
INCHES PER MINUTE
INTERCONNECTING CABLE
(SUPPLIED W/METER MODULE (1))
LOCKWASHER #6
P/N 64302860 (4)
P.H. #6—32 X .375 T.F. SCREW
P/N 61325851 (4)
F-15-336 5/96
  • Page 1 1
  • Page 2 2

ESAB Digital Meter Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI