It is highly recommended that you consult the Installation/Owner’s manual for complete instructions on all the different types of installations. The 1812 Access Plus
Telephone Entry System involves the installation of the 1812 cabinet, the by-pass board for the incoming telephone line, and wiring of these components (On reverse side).
Be sure that all dirt, metal or wood debris is removed from inside cabinet after mounting it. This could damage the control board and cause a malfunction during operation.
Remove Control Board from Cabinet
Flush Mount Cabinet in a Pilaster, Wall or Kiosk
The control board removal is the same for all models.
1. Unlock and open the 1812 Access Plus door.
2. Disconnect the keypad plug and door accessories
plug from the control board.
3. Remove the 4 screws. Carefully remove control board.
CAUTION Keep the control board in a protected area
during the installation.
SPE
A
K
ER
VOL
M
IC
V
O
L
K
E
Y
PA
D
C
O
DE
1970-010
18
11
1
2
3
45
6
78
9
10
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J2
J1
MOD
E
M
1972-010
S
W
1
1
2
3
4
5
6
7
8
BAD
D
N
S
L
A
N
D
OWN
RS-
485
R
X
J4
ON
J1
RJ-45
Jack
(Cat5)
Use existing 4 holes in cabinet box to bolt the surface or wall mount models on a DoorKing
mounting post (there are several different styles available). Use the hardware that is supplied with
the mounting post. Run all necessary wires through the post to the cabinet (See reverse side).
Mount Cabinet on a Mounting Post
Use the 4 existing holes in the cabinet box to screw the surface or wall mount models to
the wall. Run conduit inside or outside of wall or pilaster if desired. Use appropriate
hardware to mount the cabinet (Not supplied). Be sure that the mounting hardware does
not protrude into the cabinet where it could cause a short. Run all necessary wires through
the conduit to the cabinet (See reverse side).
Mount Cabinet Directly to a Wall or Pilaster
Install the By-Pass Board
The 1812 Access Plus by-pass board provides a method to by-pass the 1812 Access Plus and route the
incoming telephone line directly to the homeowner’s phone. It must be installed as part of the 1812
Access Plus system. All telephone wires for the 1812 Access Plus must pass through the by-pass board.
Mount the by-pass board in a location that is easily accessible by the homeowner. In case of 1812 Access
Plus trouble or maintenance, the homeowner will use the by-pass switch on the board to route the
incoming telephone line directly to their home phone. If the by-pass board is installed outdoors, it must be
installed in a NEMA Type 4 enclosure (not supplied) with conduit to protect the board and wires from
direct exposure to landscape sprinklers, rain, snow, and other elements.
NEMA Type 4
enclosure for
outdoor
installation.
(Not Supplied)
Use only twisted pair telephone wire that is rated for direct
underground burial (Cat5e Gel Filled (flooded) UV resistant
direct burial cable in conduit is recommended).
DO NOT use wire that is rated for indoor application use.
DO NOT run telephone wires in the same conduit as high
voltage AC wire.
It is recommended to run all necessary wires to the by-pass
board (See reverse side) in a “dedicated” telephone wire
conduit.
Ground by-pass board.
Minimum 12 AWG wire
(Not supplied).
If installed
outdoors.
Plastic screw anchors for
masonry if required.
(Not supplied)
Dedicated
Telephone
Wire Conduit
“Entry” switch position:
Routes incoming phone line through 1812
Access Plus and then to the home phone.
7
7 8 9
4 5 6
0
“By-Pass” switch position:
Routes incoming phone line directly to the
home phone, bypassing 1812 Access Plus.
7 8 9
4 5 6
0
From
Incoming
Telephone
Line
From
1812’s
18-Pin
Main
Terminal
Surface
Mount
Cabinet
Wall
Mount
Cabinet
Flush
Mount
Cabinet
Surface
Mount Curved
Cabinet
7
8 9
4 5 6
1 2 3
0
7
8
9
4 5
6
1 2
3
0
7
8
9
4
5
6
1 2
3
0
7
8 9
4
5 6
1
2 3
0
Mount rough-in box into the pilaster, wall or kiosk. Run conduit inside wall into bottom of rough-in
box if desired. Use appropriate hardware (Not supplied) to secure the rough-in box in place. Run all
necessary wires through the conduit in to the rough-in box (See reverse side).
Bolt flush mount box
into the rough-in box
with 4 supplied bolts.
R
ough-In Box
SPEAKER
VOL
MIC VOL
KEYPAD
CODE
1970-010
18
11
123
4
5
6
7
8910
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J2
J
1
MODEM
19
72-010
SW1
1
2
3
4
5
6
7
8
BAD
DNS
LAN
DOWN
RS-485
RX
J
4
ON
J1
RJ-45
Jack
(Cat5)
Flush
Mount
Box
7
8
9
4 5
6
0
Conduit
(Shown inside wall)
Conduit
(Shown inside wa
ll)
8-Pin
RS-485
Connector
18-Pin Main
Terminal
Connector
Remove the 18-pin main terminal
connector, and if necessary, the 8-pin
RS-485 connector from the control
board by gently pulling them straight
up. This will make wiring to the
control board easier. Note the
orientation and numbering sequence
of each connector to correctly wire it.
IMPORTANT The 1812 Access Plus and by-pass board
MUST be properly grounded! A gooseneck mounting post
anchored in concrete does not make a good ground.
1
CENTRAL
O
FFICE
EARTH
G
ND
PHONE
IN
PHONE
OUT
HOME
2345
6
7
8
SW1
ENTRY BY-PASS
1875-010
2
3
4
5
6
7
8
1
From
Home
Phone
Incoming
Phone Line
Home Phone
Incoming
Phone Line
Home Phone
QUICKSTART “BASIC” INSTALLATION GUIDELINES FOR AN 1812 ACCESS PLUS CABINET AND BY-PASS BOARD
OV
OV
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
KEYPAD
MASTER
CODE
1970-010
1112345678910
J2
J1
J3
18
17
16
Com
15 N.C.
14 N.O.
13 Com
12 N.C.
11 N.O.
10
9
8
7
6
5
RING
4 TIP
3 GND
2 TIP
1 RING
MODEM / TCP ENB
DATA TRANSMIT
BAD DNS
LAN DOWN
RS-485 RX
PHONE LINE
IN USE
ON
1972-010
SW1
J4
1
2
3
4
5
6
7
8
DATA TRANSMIT
BAD
DNS
LAN DOWN
RS-485 RX
PHONE LINE
IN USE
EARTH
GND
SW1
ENTRY BY-PASS
1875-010
1
CENTRAL
OFFICE
PHONE
IN
PHONE
OUT
HOME
2345678
TIP
TIP
TIP
RING
RING
RING
TIP
RING
Cat5 Cable
J1
Connector
(Cat5)
J
J
J1
J1
J1
J1
J1
J1
LAN
CONNECTION
RS-485 DATA A (+)
RS-485 DATA B (-)
RS-485 Common
It is highly recommended that you consult the Installation/Owner’s manual for complete wiring instructions on all the different types of installations, programming and internet connections.
By-Pass Board
Basic Programming for the 1812 Access Plus
Programming Simple Access Codes
Control Board
The 1812 has been programmed at the factory with many of the programming parameters (default setting) set for a typical
residential application with a single 1812 Access Plus.
However,
you must program a “Master Code” before putting the 1812 Access Plus into service. If you
are using more than a single 1812 Access Plus in the system, or if you are using any of the advanced features of the 1812
Access Plus , such as Time Zones, Do-Not-Disturb Schedules, Call Forwarding, Holiday Schedules, Hold Open Schedules,
Directory Code Dial-Out Phone Numbers, Temporary Access Codes, etc., you will need to download the complete
Installation/Owner’s and Programming Manual from our tech support web site.
Programming Relay 1 and 2 Strike Time - (Factory default is 1 second)
1. Press
*
0 3 and enter the MASTER CODE. [
*
0 3 _ _ _ _ (beep)]
2. Enter “1” for relay 1 or “2” for relay 2, then press
*
. [ _
*
(beep)]
3. Enter a two-digit strike time (00-99), then press
*
. [ _ _
*
(beep)]
Note: Strike time entered in seconds. 00 = ¼ sec., 10 = 10 seconds, etc.
4. Repeat steps 2 and 3 to set the other relay strike time if necessary.
5. Press “0 #” TOGETHER to end. [0 # (beeeeeep)]
This “Quickstart” guideline is designed for installing a single 1812
Access Plus in a typical single family home application using the
factory default settings programmed in the 1812 Access Plus.
Complete installation instructions and programming manual is
available on the enclosed CD AND from our tech support web site.
CLICK HERE TO VISIT DOORKING’S TECHNICAL WEB SITE:
www.dkaccess.com/english/Telephone_Entry/telephone_entry.html.
Blinking LED - Power is applied to the 1812
Access Plus and the processor is working
(Normal Mode).
LED ON Continuously - After master code push
button has been pressed, system will be in
Master Code programming mode. (Will revert
back to blinking LED if master code is not entered
within 10-seconds).
See Installation/Owner’s manual to configure the RS 485
access control device(s) (device address, termination
switch, programming etc). DO NOT power RS 485 device(s)
from the 1812 Access Plus power transformer.
See Installation/Owner’s manual for
different connections to the internet.
MODEM/TCP switch must be ON.
1. Press the Master Code push button.
(the LED will stay on continuously).
2. Enter a four digit Master Code number
then press “
*
”, “beep” will be heard.
[ _ _ _ _ (beep)] (Write down master code).
“Normally Open”
Vehicular
Gate Operator
(Terminal 11 and 13)
INPUT
PHONE LINE
TIP RING
1877-010
OUTPUT
TIP RING GND GND
LOW VOLTAGE LINE
OUTOUT
1878-010
ININGNDGND
INPUT
OUTPUT
Locate Homeowner’s
Phone Line Inside Device
To “Existing”
Alarm Control Panel
“Existing” Alarm System
Phone
Jack
Phone
Jack
Cat5e Cat5e
Cat5e Without Surge Board
Without
Surge
Board
Central Office (C.O.)
Demarcation Device
Cat5e
Cat5e
Recommended
Recommended
Recommended
Cat5e
Cat5e
Daisy Chain
Wiring
6 Devices
Maximum
Ground 12 AWG Min.
Orange Pair
Orange
Pair
Green
Pair
Green Pair
Ground 12 AWG Min.
Within 3 ft of Board
Ground 12 AWG Min.
Within 3 ft of Board
Ground 12 AWG Min.
Phone at
Home #12
Phone at
Home #11
Phone at
Home #13
Tip
Ring
Tip
Ring
Tip
Ring
Homeowner’s Phone(s)
“Normally Close” Pedestrian Gate/Door with Maglock
(Terminal 15 and 16)
“Normally Open” Pedestrian Gate/Door with Electric Strike
(Terminal 14 and 16)
Maglock
Electric
Strike
WA
R
NING
M
O
V
I
N
G
G
A
TE
C
A
N
C
A
U
S
E
O
p
e
r
a
t
e
g
a
t
e
o
n
l
y
w
h
en
g
a
t
e
a
r
ea
i
s
i
n
s
i
g
h
t
an
d
f
r
e
e
o
f
p
eo
p
l
e
a
n
d
o
b
st
r
u
c
t
i
o
n
s.
Do
n
o
t
a
l
l
o
w
c
h
i
l
d
r
e
n
t
o
p
l
a
y
i
n
g
at
e
a
r
e
a
o
r
o
p
er
at
e
g
a
t
e
.
Do
n
o
t
s
t
a
n
d
i
n
g
at
e
p
at
h
o
r
w
a
l
k
t
h
r
o
u
g
h
p
a
t
h
w
h
i
l
e
g
a
t
e
i
s
m
o
v
i
n
g
.
R
ead
o
w
n
e
r
s
m
a
n
u
a
l
a
n
d
s
af
e
t
y
i
n
s
t
r
u
c
t
i
o
n
s
.
S
E
RIO
U
S
I
N
J
U
RY
O
R
DE
A
T
H
C
L
A
S
S
C
E
R
T
I
F
IE
D
T
O
C
A
N
/
C
S
A
C
2
2
.
2
N
O
.
2
4
7
C
ON
F
OR
MS
T
O
A
N
S
I
/
U
L
-
3
2
5
V
E
H
I
C
U
LA
R
G
A
TE
O
P
E
R
A
TO
R
H
P
5
3
3
8
2
M
O
D
E
L
S
E
R
I
A
L
V
OL
T
S
P
H
A
S
E
A
M
P
S
6
0
H
z
M
A
X
G
A
T
E
L
O
A
D
D
o
o
r
K
i
n
g
,
I
n
c.
,
I
n
g
l
e
w
o
o
d
,
C
A
TIP (
+
):
White/blue mark
RING (-):
Blue/white mark
Magnetic locks or electric strikes must be powered from a
separate UL Listed power transformer. DO NOT power electric
strikes or magnetic locks from the 1812 Access Plus power
transformer. keep power wire runs as short as possible.
Use common electrical safety practices when connecting
telephone wires. You can receive a substantial jolt if the
phone rings while handling these wires.“RING” terminal
voltage varies and can be between -48 to -130 Volts AC,
depending on the distance to the central office.“TIP”
terminal is always positive with respect to RING terminal.
The By-Pass board is required.
Phone Line Surge Suppressor
Optional P/N 1877-010
Low Voltage
Surge Suppressor
Optional P/N 1878-010
Separate UL
Listed Power
Transformer
Separate UL Listed power transformer if needed.
Check Polarity of Telephone Line
Check for polarity on the incoming telephone line to each board and maintain polarity
throughout the telephone line (TIP (+), RING (-).
Cat5e Gel Filled (flooded) UV resistant direct burial cable run in conduit recommended.
DO NOT run telephone wires in the same conduit as high voltage AC wire.
J1
Main
Terminal
RS 485
Terminal
TIP
Older Lines
Green Wire (+)
Older Lines
Red Wire (-)
RING
Ground
Ground
Ground
Ground
O
utput
16.
5 VAC
20 VA
16.5
VAC
MODEM/ TCP ENB
Switch Turned ON
Phone In
(1-2)
Relay 1
(11-13)
Note: Each relay can control a
normally open OR normally close
access control device. Relay
contacts are rated for 3 amps @
30 VAC maximum.
SPEAKER
VOL
MIC VOL
Wire Size Max Distance
24 AWG
22 AWG
20 AWG
18 AWG
800 ft
1600 ft
2200 ft
3600 ft
Telephone and RS 485 Wire Run (Cat5e) Table
Wire Size Max Distance
18 AWG
16 AWG
100 ft
200 ft
Power Transformer and Access Control Device(s)
Wire Run Table
CAUTION
DO NOT power the 1812 Access Plus from
a 24-Volt source (Such as a gate operator).
Damage will occur to the 1812 Access
Plus that is NOT covered under DoorKing’s
warranty.
Supplied Power
Transformer
Polarity does not matter.
Push Button to Program “Master Code”
To LAN/Router/Gateway
Program MASTER CODE
Master Code LED Description
Access Control Devices
7
7
8
9
4 5 6
1
2 3
0
RJ31x
Phone Jack
installed
Before 1812
System
Telephone Company
Demarcation Point
RS 485 Remote Device(s)
Complete Instructions
Programming Simple Access Code(s) to Operate Relay 1 and/or 2 on a 24/7 Basis - (Maximum of 50 codes)
1. Press
*
0 2 and enter the MASTER CODE. [
*
0 2 _ _ _ _ (beep)]
2. Press 1 for relay 1 OR Press 2 for relay 2, then press
*
. [ _
*
(beep)]
3. Choose and enter a five-digit simple access code, then press
*
. [ _ _ _ _ _
*
(beep)]
4. Repeat steps 2 and 3 to enter additional simple access codes.
5. Press “0 #” TOGETHER to end. [0 # (beeeeeep)]
Cat5 Wire
Four Conductor
Wire
Tip (+)
1st Line
Wire
Conversion
2nd Line
3rd Line
4th Line
Green
Red
Black
Yellow
Blue Pair
Orange Pair
Green Pair
Brown Pair
Ring (-)
(+) Tip
(-) Ring
(+) Tip
(-) Ring
(+) Tip
(-) Ring
Older
Residential
Homes
Modern
Residential
Homes
Phone Wiring
Basics “101”
Relay 2
(14-16)
Power
(17-18)
Phone Out
(4-5)
IMPORTANT All boards
MUST be properly
grounded or the system
will NOT function correctly!
QUICKSTART “BASIC” WIRING GUIDELINES FOR AN 1812 ACCESS PLUS SYSTEM WITH ACCESS CONTROL DEVICE(S)
Co
py
ri
g
ht 2011 DoorKin
g
, Inc. All ri
g
hts reserved.
1
8
12-1
68
-D-12-11
Over Voltage Power Note: LED located on
bottom left corner of board will light up if
too much power is applied to circuit board.
OV
OV
  • Page 1 1