Vemer iRide, Iride 230, VE456000 User manual

  • Hello! I'm your chat assistant, ready to help with your Iride and Iride 230 chronothermostat. I've reviewed the user manual and know the devices' features well, including the weekly programming, summer/winter modes, and touch screen interface. I can guide you through installation, setting up programs, and understanding regulation options. Feel free to ask any questions about the device!
  • What kind of power supply does the Iride chronothermostat use?
    What kind of power supply does the Iride 230 chronothermostat use?
    How many programs are available for the heating mode?
    Does the device have a display backlight?
    Can I remotely control the chronothermostat?
    What type of mounting is supported?
Chronothermostat
IRIDE
User Manual
- 1 -
Iride Chronothermostat User Manual
Content of the package Page 3
Connection diagrams Page 3
Mounting Page 4
Safety warnings Page 16
Technical features Page 17
Display and keyboard Page 18
Installation Page 19
Programming menu Page 22
- Time and date modification Page 22
- Programs modification Page 23
- Temperatures T1,T2,T3 modification Page 24
- Timing setting Page 26
- Advanced functions menu Page 27
Manual operation Page 30
Off operation Page 31
Backlighting management Page 33
Minimum and maximum value Page 34
Summer time change Page 34
Regulation type Page 36
Timings: what they are Page 38
Device reset Page 40
Battery replacement Page 40
Reference standards Page 41
Default values Page 42
Winter preset programs Page 43
Summer preset programs Page 44
Index
English
- 2 -
Iride Chronothermostat User Manual
Digital chronothermostat IRIDE
Touch screen display of capacitive type
(sensible to the fingers’ touch)
Multicolour display red-green-blue according
to the gap between the measured temperature
and the set one (230V model only)
Digital input for the connection of a telephone
dialler for switches on and switches off of the
device remotely
Summer and winter operating mode
Front panels of white and anthracite
grey colour included in the package
(you can buy silver on request)
Battery or 230V power supply
7 programs available for the heating
mode
7 programs available for cooling
mode
Weekly programming with 3 different
settable temperatures levels
Flush-mounting on 3 modules box
(503 type)
English
- 3 -
Iride Chronothermostat User Manual
CONTENT OF THE PACKAGE
CONNECTION DIAGRAM
Chronothermostat
frames and plastic elements available in white and anthracite grey colors
frames mount A
mount B
plastic
elements VI plastic
elements BM
COM
NA NC
NL
230V~
Iride 230
Iride
COM
NA NC
1 2 3 4 5
1 2 3 4 5
X.code
mount AIR
English
- 4 -
Iride Chronothermostat User Manual
BATTERY IRIDE MOUNTING
A
Bticino Living series, Light, Light Tech, Livinglight, Axolute
Vimar Eikon series, Eikon Evo, Plana
Ave S44 series – ABB Mylos series
English
- 5 -
Iride Chronothermostat User Manual
IRIDE 230 MOUNTING
Bticino Living series, Light, Light Tech, Livinglight, Axolute
Vimar Eikon series, Eikon Evo, Plana
Ave S44 series – ABB Mylos series
A
English
- 6 -
Iride Chronothermostat User Manual
BATTERY IRIDE MOUNTING
ABB Chiara series
Vimar Arké series
B
English
- 7 -
Iride Chronothermostat User Manual
IRIDE 230 MOUNTING
ABB Chiara series
Vimar Arké series
B
English
- 8 -
Iride Chronothermostat User Manual
BATTERY IRIDE MOUNTING
Gewiss Chorus series
B
Remove the cogs
English
- 9 -
Iride Chronothermostat User Manual
IRIDE 230 MOUNTING
Gewiss Chorus series
B
Remove the cogs
English
- 10 -
Iride Chronothermostat User Manual
BATTERY IRIDE MOUNTING
Bticino Matix series
B
BM
Remove the cogs
English
- 11 -
Iride Chronothermostat User Manual
IRIDE 230 MOUNTING
Bticino Matix series
B
BM
Remove the cogs
English
- 12 -
Iride Chronothermostat User Manual
BATTERY IRIDE MOUNTING
Vimar Idea series
VI
B
English
- 13 -
Iride Chronothermostat User Manual
IRIDE 230 MOUNTING
Vimar Idea series
VI
B
English
- 14 -
Iride Chronothermostat User Manual
BATTERY IRIDE MOUNTING
Bticino Livinglight AIR series
AIR
Note: if the box extension is not present (adapter which increases the
depth of the flush-mounting box) we recommend you using the frame
for Livinglight AIR installation
*
English
- 15 -
Iride Chronothermostat User Manual
IRIDE 230 MOUNTING
Bticino Livinglight AIR series
AIR
Note: if the box extension is not present (adapter which increases the
depth of the flush-mounting box) we recommend you using the frame
for Livinglight AIR installation
*
English
- 16 -
Iride Chronothermostat User Manual
BATTERY IRIDE MOUNTING
Bticino Livinglight AIR series
AXO AIR
Mount AXO AIR is not included in the package.
English
- 17 -
Iride Chronothermostat User Manual
IRIDE 230 MOUNTING
Bticino Livinglight AIR series
AXO AIR
Mount AXO AIR is not included in the package.
English
- 18 -
Iride Chronothermostat User Manual
During product installation and operation it is necessary to observe the
following instructions:
1) The device must be installed by a qualified person, in strict compliance with
the connection diagrams.
2) Do not power or connect the device if any part of it is damaged.
3) After installation, inaccessibility to the connection terminals without
appropriate tools must be guaranteed.
4) The device must be installed and activated in compliance with current electric
system standards.
5) Before accessing the connection terminals, verify that the leads are not live.
6) In the electrical system of the building where the device must be installed
and a protection device from the overcurrents must be present (for Iride 230
models only).
Code Model Description
VE456000
Iride Touch screen chronothermostat batteries
VE457800
Iride 230 Touch screen chronothermostat 230V
SAFETY WARNINGS
Electronic touch screen chronothermostats series with flush-mounting on 3 modules
box (503 type) suitable for the temperature control in household.
Two versions are available:
Iride, battery powered, with backlit monocolour display (blue) and input for external
contact with whom to switch on/to switch off the chronothermostat remotely (by
telephone)
Iride 230, mains powered, with backlit monocolour display, which changes tone
according to the gap between the environment temperature and the setpoint
These devices perform actions of 1B type and are intended for operating in
environments Pollution degree 2 and Overvoltage Category III (EN 60730-1).
English
/