GCL-MT operators are covered by the following U.S. patents: 7355363, 7878931, 8014966
The GCL-MT is designed for standard-lift sectional
doors that have a limited-duty cycle requirement.
Advanced features and robust mechanical design
combine to provide a medium-duty operator that is
the new standard in the industry
UL325-2010 APPROVED
• Allowsformonitoredentrapmentprotectionand
momentaryoperationwhenusedwithselectphotoeyes
and/oredge-sensingdevices.
• Seebackforapprovedlistofmonitoreddevices.
GCL-MT Advantages
• Ratedfor15cyclesperhouroperation.Maximizingthe
performanceoutofamedium-dutyoperator.
• Modulardesignwithoptionalexpansionboardsfor
advancedtimertoclose,andauxiliaryoutputfunctionality.
• Optional:Intellicode®Iplugandplayreceiverlearnsupto
50transmitters.Learnanddeleteindividualtransmitters
directlyfromLCDdisplay.
• TensiBeltprimarydrivereductioneliminatesneedto
adjustbelttension.
• Availableineither115Vor230VAC1Ø60Hz.
Expandedofferingincreasesapplicationsavailablefor
medium-dutyuse.
• Motorwithbuilt-inthermalprotectionandballbearing
driveend.Providesoverloadprotectionandbearings
extendlifeofmotorovertypicalbushings.
• LCDdisplaywithintuitivesetupmenu.Providesreal-time
statusandtrouble-shootingassistance.
• Open/close/stopandsetupkeysincludedoncontrol
board.KeepsallcontrolsneartheLCDdisplayconvenient
forsetup.
Standard Features
• 11.5inchesperseconddoorspeed.
• Opticallimitsystemwithlineartravelnuts.
• Maxruntimerautomaticallyadjuststoupanddownruntime.
• TensiBeltprimaryreduction.
• Delayonreverse.
• 16-characterLCDdisplay.
• UL325-2010approved.
• Drawbardisconnectforemergencymanualoperation.
• 3-buttoncontrolstation.
• 2-year/20,000-cyclewarranty.
• Programmablemid-stop.
GENIE®
COMMERCIAL OPERATORS
GCL-MT
MEDIUM-DUTY TROLLEY OPERATOR
www.GenieCompany.com/commercial | 800.843.4084
©2012 The Genie Company | GCL-MTss
Dealer Imprint Area
GCL-MT | MEDIUM-DUTY TROLLEY OPERATOR
MAX DOOR SIZE (SQ*FT) - SECTIONAL
Door Series
Commercial Steel Insulated & Non-Insulated Thermospan®ThermoMarkAluminum
216 216
Ins. 220 220
Ins. 2415 2415
Ins. 2411 2411 Ins. 125 150 200 200-20 5150 5200 451 452
Flush Ribbed Insulated Insulated
Model
Max
Door
Wt.
(lbs.)
16GA. 16GA.
Ins.
20GA.
Steel
20GA.
Ins. 24GA. 24GA.
Ins.
Nominal
24GA.
Nominal
24GA.
Ins.
PU-FIP PU-FIP
1.38”
PU-FIP
2”
PU-FIP
2
20GA.
Ext.
PU-FIP
Raised
Panel
1.38”
PU-FIP
Raised
Panel 2”
1/8”
Glass
1.38”
1/4” or
1/2”
Glass
1.38”
1/2 HP 620 170 120 230 160 270 200 300 256 256 256 240 160 256 256 210 144
1.MaxDoorWeightandnotthesquarefootage,isthecriticalfactorinselectingtheproperoperator.
2.MaxDoorHeight14’
3.For“CommercialSteelInsulated”category,various“backer”optionsareavailable.Thechartaboveisbasedinallcasesonthethickestbackeravailable.
4.“PU-FIP”standsfor“polyurethane,foamed-in-place.”Ifnonotationispresent,insulationis“polystyrenelaid-in-place.”
Notes:
Construction
• Motor
1/2HP,ACcapacitorstart/runmotor.Motorreplaceablewithout
changinglimits.
• Drive
Primary—TensiBeltautotensioningpoly-VJbelt.
Secondary—chainandsprocketreduction.
• Friction Clutch
Adjustableclutchtohelpprotectagainstdoorand
operatordamage.
• Precision Radial Ball Bearings
Includedincriticalareasthroughoutthepowertrain.
• Rail Assembly
2”doortrackwithnylonrailrunnersandchainguides.
• Pre-wired to accept:
-Monitoredentrapmentdevicesuchasphotoeyes.
-Singleor3-buttoncontrolstations.
-Externalinterlockswitches.
Accessories and Options
• Brake
ACsolenoidactuatedbandbrake.Mustbeorderedfromfactory.
• Timer to Close Module
TimedclosesetviatheLCDdisplayfrom2secondsupto5
minutes.Includespre-closewarningcontacts,timerholdinput,
auxiliaryopeninput,normallyclosedsafetyinput,andmonitored
edgeinput.
• Auxiliary Output Module
Providesrelaycontactsattheopen,close,andmid-stoplimits.
Contactsfor5-minutelamp,and“ADAcontactssetviaLCDdisplay
towarnduringopening,closingorboth.
• 315Mhz Receiver Module
IntelliCode®Iradioreceiverthatis315Mhzandcapableofstoring
50single-buttonand/or50open-close-stoptransmitterswiththe
abilitytoaddand/ordeletetransmittersindividually,identifyand
storeactivatingtransmitterID(s).
• UL325-2010 Approved Reversing Devices
Theinstallationofamonitoredexternalentrapmentdeviceis
requiredformomentarycontactcloseoperationonallcommercial
dooroperators.Onlythefollowingdevices,whenpurchasedthrough
Genie,areUL-Approvedforusetomeetthisrequirement:
• Safe-T-Beam®PhotoeyeKitwithadjustablebracket
P/N38176R.S1
• Impact-protectedCommercialPhotoeyeKitP/NOPAKPE.S
• MillerEdgeME/MT/CPT(DCorT3)2-wireedgesensor.
MustbeusedwithTCM(OPABTCGX.S)orInterfaceModule
(OPAKMEIGX.S).
• Nema4PhotoeyesP/NOPAKPEN4GX.S
1— Default device when operator is ordered.
AMPERAGE RATING 1Ø 60Hz
HP 115V 230V
1/2 6.5 3.1
17"
13
16
"
10 15
16
"
DOOR HEIGHT + 4' MINIMUM
39
16
"
63
16
"
12 3
8
"
611
16
"
55
8
"
MOUNTING BRKT
HIGHEST POINT
OF DOOR
DURING TRAVEL
REVISIONS
ER
REV DESCRIPTION
DATE
APPROVAL
501348
-
ORIGINAL ISSUE
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
E
F
E
F
GMXT TECHNICAL INFO
-
NOTES: (UNLESS OTHERWISE SPECIFIED)
11/10/11
FINISH
MATERIAL
HOLES:
< Ø.251 =
.003
Ø.251-Ø.500 =
.003
> Ø.500 =
.003
112214
INCHES
WDR
10/20/2011
WDR
11/9/11
DO NOT SCALE
A SUBSIDIARY OF OVERHEAD
DOOR CORPORATION
TOLERANCES:
DRAWN
112214-GMXT
INTERPRET DIMS & TOLS
PER ASME Y14.5M
DIMS CIRCLED WITH
SYMBOL '
' ARE CRITICAL
TO QUALITY DESIGN
FEATURES & MUST MEET
APPLICABLE IN-PROCESS
INSPECTION STANDARDS.
ALL DIMS ARE IN
UNLESS OTHERWISE SPECIFIED
SCALE 1:3
DWG NO.
SIZE
DESCRIPTION
APPROVALS
DATE
ALL GEOMETRY GOVERNED BY 3D CAD DATABASE
:
APPROVED
CHECKED
.X = ±.1
.XX = ±.01
.XXX = ±.005
ANGULAR = ±1
SHEET 1 OF 1
THIRD ANGLE PROJECTION
ALLIANCE, OHIO
D
PLOTTED: 10/20/11
MS
THE DRAWINGS AND ALL OTHER
INFORMATION CONTAINED HEREIN ARE
THE CONFIDENTIAL PROPRIETARY
PROPERTY OF OVERHEAD DOOR
CORPORATION, INCLUDING ITS
AFFILIATED SUBSIDIARIES AND
AFFILIATES. THIS DRAWING
INFORMATION, IN WHOLE OR IN PART,
MAY NOT BE COPIED IN ANY MANNER OR
DISCLOSED TO ANYONE WITHOUT PRIOR
WRITTEN CONSENT OF OVERHEAD DOOR
CORPORATION. DISCLOSURE OF ANY
DRAWING OR INFORMATION IS INTENDED
NOT TO AND SHALL NOT OPERATE AS A
LICENSE OR AUTHORIZATION TO USE IT
FOR ANY PURPOSE WITHOUT SPECIFIC
WRITTEN CONSENT OF OVERHEAD DOOR
CORPORATION.
P/N 112214-0001
/