Marantec Protect-Opto 602 Owner's manual

Type
Owner's manual

Marantec Protect-Opto 602 is a safety device that protects people from getting injured by a closing/opening door or gate. It does this by using photocells mounted on the door or gate to detect obstacles in its path. When an obstacle is detected, the door or gate will stop moving and reverse direction.

The Protect-Opto 602 is compatible with various Marantec control units, including the CS 300, CS 310, and 400. It is easy to install by following the steps outlined in the included instructions.

Key Features:

  • Adjustable mounting brackets for flexible positioning
  • Self-monitoring system for increased reliability

Marantec Protect-Opto 602 is a safety device that protects people from getting injured by a closing/opening door or gate. It does this by using photocells mounted on the door or gate to detect obstacles in its path. When an obstacle is detected, the door or gate will stop moving and reverse direction.

The Protect-Opto 602 is compatible with various Marantec control units, including the CS 300, CS 310, and 400. It is easy to install by following the steps outlined in the included instructions.

Key Features:

  • Adjustable mounting brackets for flexible positioning
  • Self-monitoring system for increased reliability
Protect
-Opto 602
EN
ENGLISH
Page 1 of 8
Rev.A 08
Installation
1. Screw the mounting brackets to the leading photocell
2. Close the door
3. Position the leading photocell on the door by placing it on the floor in the
folded up state
4. Fix the brackets to the door
Distance between lower edge of bracket and lower edge of door:
130< x <160 mm
Notes:
During initial operation and annual servicing, test runs must be carried out
with the door at several different heights
The two photocells must be fitted to the door leaf at the same height
The photocells must run directly along the guide rail in their unfolded state so
that they monitor the entire clearance
The receiver should be protected from direct sunlight
EN
ENGLISH
Protect
-Opto 602
Page 2 of 8
Rev.A 08
Connection of the photocells to the control unit
Control unit
br
ws
gr
ge
ws
br
gr
ge
br ws
gr
br = brown
ws = white
gr = green
ge = yellow
Protect
-Opto 602
EN
ENGLISH
Page 3 of 8
Rev.A 08
Electrical Connection to the CS 300
The leads of the transmitter and receiver units are connected in parallel
according to the colours and are connected up to the CS 300 with a spiral
cable
The two yellow leads of the leading photocell must be wired through
The pre-limit switch CLOSE must be correctly adjusted
Connection to the CS 300:
brown
1
2
Relais 1
X5
X4
5
6
7
8
8K2
green
white
CS300
CS300 – MOD 12
CS300ME – MOD 11
CS300FS – MOD 11
Setting the Parameter SKS VOR on MOD 2
Adjustment of the pre-limit switch CLOSE
For CS300, set the mode for relay 1 to 12 (pre-limit switch CLOSE - limit
switch CLOSE)
For CS300ME / CS300FS, set the mode for relay 1 to 11 (pre-limit
switch CLOSE)
Close the door until the leading photocell just touches the ground
Read off the current position of the door in the diagnostic menu (only in the
case of AVE)
Set the pre-limit switch CLOSE to this position
EN
ENGLISH
Protect
-Opto 602
Page 4 of 8
Rev.A 08
Electrical Connection to the CS 310
The leads of the transmitter and receiver units are connected in parallel
according to the colours and are connected up to the CS 310 with a spiral
cable
The two yellow leads of the leading photocell must be wired through
The Revers OFF Point must be correctly adjusted
Connection to the CS 310:
brown
X4
5
6
7
8
green
white
CS310
Adjustment of the Revers OFF Point
Close the door until the leading photocell just touches the ground
Read off the current position of the door in the diagnostic menu (only in the case
of AVE)
for example: 4150
Close the door fully
Read off the current position of the door in the diagnostic menu (only in the case
of AVE)
for example: 4000
Enter the difference (for example:150) in the input menu, in the menu item
“REVERSAL POINT”
Set the menu point “SCS REV” to MOD 2
(stop + reverse between the upper limit switch and the reversal point, no action
between the reversal point and the lower limit switch)
Protect
-Opto 602
EN
ENGLISH
Page 5 of 8
Rev.A 08
Electrical Connection to the CS 400
The leads of the transmitter and receiver units are connected in parallel
according to the colours and are connected up to the CS 400 with a spiral
cable
The two yellow leads of the leading photocell must be wired through
The pre-limit switch CLOSE must be correctly adjusted
Connection to the CS 400:
brown
A
1
A
2
Relais A
8K2
green
white
CS400
CS400 –
MOD 12
24
44
25
45
Adjustment of the pre-limit switch CLOSE
For CS400, set the mode for relay 1 to 12 (pre-limit switch CLOSE - limit
switch CLOSE)
Close the door until the leading photocell just touches the ground
Read off the current position of the door in the diagnostic menu (only in the
case of AVE)
Set the pre-limit switch CLOSE to this position
EN
ENGLISH
Protect
-Opto 602
Page 6 of 8
Rev.A 08
Protect
-Opto 602
EN
ENGLISH
Page 7 of 8
Rev.A 08
EN
ENGLISH
Protect
-Opto 602
Page 8 of 8
Rev.A 08
#1700026058
#120173
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Marantec Protect-Opto 602 Owner's manual

Type
Owner's manual

Marantec Protect-Opto 602 is a safety device that protects people from getting injured by a closing/opening door or gate. It does this by using photocells mounted on the door or gate to detect obstacles in its path. When an obstacle is detected, the door or gate will stop moving and reverse direction.

The Protect-Opto 602 is compatible with various Marantec control units, including the CS 300, CS 310, and 400. It is easy to install by following the steps outlined in the included instructions.

Key Features:

  • Adjustable mounting brackets for flexible positioning
  • Self-monitoring system for increased reliability