Audioplex SLVC75 Installation guide

Type
Installation guide

This manual is also suitable for

Attenuator type: Tapped auto transformer.
Switch: 12 position slide, make-before-break contacts
Connector: Screw-tight type
Input Power Rating: SLVC75: 25 Watts RMS continuous, 35 Hz-20 KHz.
SLVC200: 72 Watts RMS continuous, 35 Hz-20 KHz
Core Saturation: Studies reveal that core saturation @ 35Hz is 25W.
Frequency Response: +0, -1 dB worst case (-6 dB tap), +0, -0.2 dB all other
taps, 35 Hz-20 KHz.
Measured at full power, 8 Ohm load. Most controls
better these specifications.
Transformers: Tri-filar wound for flat response and minimum phase
shift, grain-oriented, high silicon steel laminations.
Attenuation: -34 dB in 12 steps, 8 steps @ -3 dB each, 1 step @ 4 dB,
1 step @ -6 dB, last step OFF.
Mounting: Fits in most standard single electrical junction boxes,
depth less than 2".
INSTALLATION:
Before starting connections, please note that the left and right attenuator circuits are
completely isolated from each other to prevent instability when used with certain types of
amplifiers which have floating grounds. If the amplifier to be used has common grounds between
channels, a 3 wire system can be used between the amplifier and control, but it will be necessary
to connect a jumper between the control ground returns (L- & R-). If one ground is open, there
will be no output on the ungrounded channel at any attenuator setting.
The connectors on the attenuator are the screw-to-tighten type. See the diagram on the back of
this instruction sheet.
1. Make connections by stripping wire insulation back about 3/16". Twist any loose strands tightly.
2. Insert the wires from the amplifier into the INPUT openings of the connector, hot to hot and ground
to ground, then tighten screws. Check for stray wire strands that might cause a short circuit. Make
sure the metal part of the screw connector engages the bare wire, NOT the insulation!
3. Similarly, connect speaker wires to the control OUTPUT openings and tighten screws.
4. Install control in its operating location. Suggestion: Leave control 3 or 4 positions from
maximum before firing-up the system for the first time to avoid "blasting" the speakers, while still
having enough sound to observe operation.
Installation must be made by qualified service personnel, and must meet all local codes.
TECHNOLOGY
INSTALLATION MANUAL
2003 - 10/16/03
SLVC75 / SLVC200 STEREO VOLUME CONTROLS
Your AUDIOPLEX TECHNOLOGY Stereo Speaker Volume Control is covered by a LIFETIME
warranty against any defects in workmanship and materials. Any defects will be remedied without charge
for labor or parts.
Damage incurred by shipping or accident is not considered to be a defect, and not covered by this
warranty. AUDIOPLEX TECHNOLOGY, is not responsible for defective operation caused by abuse or
by modification or service by any unauthorized person or agency.
The product must be properly installed and operated according to instructions for the warranty to apply.
Any necessary servicing must be done by AUDIOPLEX TECHNOLOGY. The product must be returned
expenses prepaid, with written authorization from the company. The product must be shipped with the
proof of purchase and in the original carton and packing material to avoid damage.
This warranty gives you specific legal rights. You may have other rights which vary from state to state.
WIRING DIAGRAM
- R +
+ L -
VOLUME CONTROL
(BACK VIEW)
- R +
+ L -
AMPLIFIER
SPEAKER OUTPUT
L+
OUTPUT
INPUT
L+R+ R+L- L-R- R-
AUDIOPLEX TECHNOLOGY
404 GWH P.O. BOX 440
MELVIN VILLAGE, N.H. 03850
1-800-257-2077 1-603-544-8601 FAX: 1-603-544-8901
2003 - 10/16/03
WARRANTY
  • Page 1 1
  • Page 2 2

Audioplex SLVC75 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI