SPT AC-3000i User guide

Type
User guide

This manual is also suitable for

HEPA Air Cleaner
with Ionizer
Model AC
-
3000
i
INTRODUCTION
Congratulations on your choice of the MAGIC CLEAN
HEPA Air Cleaner with Ionizer. We highly recommend
that you operate the Air Cleaner 24 hours a day, because
indoor air can be quickly contaminated by activity or
objects in a room and infiltration of outside air. Air
cleaners are much more effective in rooms where all
doors and windows are closed.
SETUP
Your Air Cleaner was thoroughly inspected and tested at
the factory prior to packaging. Visually inspect it upon
removal from its packaging. Return the unit if it shows any
signs of damage or mishandling.
WARNING:
should ONLY be plugged into a polarized 120 Volt AC
outlet.
Owners Manual
SUNPENTOWN INTERNATIONAL INC.
STRUCTURE
Main Body
HEPA & Carbon
Filter Package
Front Grill
IMPORTANT SAFETY INSTRUCTIONS
Please read all instructions before using this product.
Save these instructions for easy reference. When using
electrical appliances, basic precautions shoul
d always be
followed to reduce breakage, risk of fire, electric shock
and injury to persons including the following:
l Do not use air cleaner outdoors.
l Do not use air cleaner too close to the wall, to avoid
the wall getting dirty.
l Never operate air cleaner without the filter properly
installed. Permanent motor damage could result.
l Never use air cleaner unless it is fully assembled.
l Do not use air cleaner where combustible gases or
vapors are present.
l Do not allow foreign objects to enter ventilation or
exhaust opening as this may cause electric shock or
damage to the air cleaner. Do not block air outlets or
intakes.
l The air cleaner has a polarized plug (one blade is
wider than the other). To reduce risk of shock, this
plug is intended to fit in a polarized outlet only one
way. If the plug does not fit fully in the outlet, reverse
the plug. DO NOT attempt to defeat this safety feature.
l The Air Cleaner should ONLY be plugged into a 120
Volt AC outlet.
l A loose fit between the plug and the AC outlet
(receptacle) m
ay cause overheating and a distortion of
the plug. Contact a qualified electrician to replace
loose or worn receptacles.
l Unplug from wall outlet before servicing.
OPERATION
Room air is drawn into the Air Cleaner through the Front
Grill and passes through the filter. The filtered air is
released from the top of the unit and is dispersed into the
room. The air cleaner has two operating speed with a
slider switch. Besides, the Ionizer function can obviously
increase the efficiency in attracting dusts, and restrain
the propagating of the bacteria.
FILTER REPLACEMENT
The filter is specially designed for easy replacement to
ensure maximum performance. THE FILTER shall be
replaced every 6 (six) months depending on usage
(The replacement filter item number is AC-3000F). The
efficiency and air volume output will begin to decrease
dramatically when the filter needs to be changed.
The steps of replacing the filter are as below:
1. Turn the Air Cleaner OFF and unplug the unit from the
power outlet.
2. Carefully lay unit down on a flat surface with the Front
Grill facing up.
3. Using finger pressure in the two notches located on top
of the front grill, pull front grill out and away.
4. Remove and discard the old filter.
5.
Remove any protective plastic wrapping and packaging
from the new filter.
6. Set new filter into the air cleaner.
7. Install the Front Grill by placing the top edge of the grill
near the top of the air cleaner, lining up the grill tabs
with the air cleaner slots.
8. Snap Front Grill into place by pushing down carefully
near the bottom edges of the Front Grill.
9. The Air Cleaner is now ready for operation.
FILTER CHANGE CALENDAR
CLEANING THE UNIT
1. Turn Air Cleaner OFF and unplug from power outlet.
2. Clean unit with a moistened soft cloth only. DO NOT
pour or splash water on the unit or use any abrasive
type cleaner on it. Clean all external surfaces,
especially the air intake grilles and air outlet.
3. DO NOT attempt to clean the filter; it is NOT washable
and washing will damage it.
4. Reposition Air Cleaner, plug into power outlet and turn
ON.
STORAGE
1. Remove filter from the unit.
2. Wrap the filter in an airtight plastic bag or plastic wrap.
Be sure that the filter is totally sealed to protect it from
its storage environment.
To restore the Air Cleaner to service:
1. Unwrap the filter.
2. Install filter in the air cleaner. See Filter Replacement
section for proper installation.
TECHNICAL SPECIFICATIONS
CUSTOMER ASSISTANCE LINE
If you experience a problem, please see the warranty for
information. Please DO NOT attempt to repair this unit
yourself. Doing so will void your warranty and could cause
damage to the air cleaner or personal injury to yourself. If
you have any questions concerning this appliance, please
call:
1-626-330-8888
REPLACEMENT PARTS
The Filter Change Calendar on the top panel can help you
remember to change filter.
Set the month when
replacing the filter
Length 6.7 inch
Width 14.96 inch
Height 14.37 inch
Weight 9.55 lb
Input voltage 120 volts AC, 60Hz
Replacement Filter AC-3000F
YOUR GUARANTEE
If this product is found to be faulty as a result of faulty
materials or workmanship within 1 year from date of
purchase, it will be repaired or replaced free of charge.
This guarantee is subject to the following terms:
1. Sunpentown must be notified of the fault.
2. Proof of purchase must be presented to
Sunpentowns nominated representative.
This GUARANTEE is in addition to your Statutory Rights.
Please keep this warranty for your record. DO NOT return it.
SUNPENTOWN INTERNATIONAL INC.
3. The warranty will be void if the product is modified,
misused or repaired by an unauthorized person.
4. The guarantee after repair or replacement will not be
extended beyond the original one-year period.
5. All replacement parts or units will be new or
reconditioned.
6. Parts or units, which are replaced, become the
property of Sunpentown.
7. The warranty applies for the use of the product in the
USA.
8. Warranty does not include freight charges.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

SPT AC-3000i User guide

Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI