  • Hello! I am an AI chatbot trained to assist you with the Sans Digital Towerraid 6G series Detailed Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
2
Copyright
Copyright © 2013 Sans Digital. This document contains materials protected by International Copyright
Laws. All rights reserved. Nopartofthis manual may bereproduced, transmitted or transcribedin any
formandforanypurposewithouttheexpresswrittenpermissionofSansDigital.
Trademarks
Companiesandproductsmentionedinthismanualareforidentificationpurposeonly.Productnamesor
brand names appearing in this manual mayor may not be registered trademarks or copyrightsof their
respectiveowners.BackupyourimportantdatabeforeusingSansDigital'sproductsanduseatyourown
risk.Inno
eventshallSansDigitalbeliableforanylossofprofits,orfordirect,indirect,special,incidental
or consequential damages arising from any defect or error in Sans Digital's products or manuals.
Informationinthismanualissubjecttochangewithoutnoticeanddoesnotrepresentacommitmenton
the
partofSansDigital.
Notice
Reasonableefforthasbeenmadetoensurethattheinformationinthismanualisaccurate.SansDigital
assumesnoliabilityfortechnicalinaccuracies,typographical,orothererrorscontainedherein.
3
TableofContents
SansDigitalTowerRAIDSATA6GtoeSATA6GPortMultiplier.......................................................5
Overview.........................................................................................................................................5
SansDigital2ndGenerationSATA6Gb/sPCIE2.0RAIDController...........................................5
Chapter1‐FeaturesandSpecifications.........................................................................................6
HardwareSpecifications..............................................................................................................6
Monitor,AlertsandLEDIndicators.............................................................................................6
AdvancedRAIDFeatures.............................................................................................................
6
OperatingSystemSupport..........................................................................................................6
Chapter2‐PhysicalSpecifications..................................................................................................7
Chapter3‐KitContents..................................................................................................................8
Chapter4‐HardwareDescriptionandInstallation.........................................................................9
4.1RocketRAID642LHostAdapterboardlayout................................................................9
4.2 InstallingtheRocketRAID642LHostAdapter.................................................................9
4.3 VerifyingInstallation......................................................................................................10
Chapter5
‐RocketRAID642LBIOSUtility.....................................................................................11
5.1 BIOSSettingsOverview.................................................................................................11
5.2 UsingtheBIOSUtility....................................................................................................11
5.3 BIOSCommands............................................................................................................12
5.4 CreatingRAIDArrays.....................................................................................................14
5.5DeleteArrays................................................................................................................23
5.6 Add/RemoveSpareDisks..............................................................................................25
5.7 Settings..........................................................................................................................25
5.8 View...............................................................................................................................27
Chapter
6‐RocketRAID642LDriverInstallation...........................................................................30
6.1 Driverinstallation‐MSWindowsServer2012,2008,2003andWindows8,7, Vista..30
6.1.1 InstallingthedriverforanexistingWindowsoperatingsystem...........................30
6.1.2 InstallingthedriverduringafreshWindowsOSinstallation................................36
6.2 Driverinstallation‐Linux
andFreeBSD..........................................................................38
Chapter7‐SansDigitalWebRAIDManagementSoftware..........................................................40
7.1 Installing/UninstalltheWebRAIDManagementSoftware‐MicrosoftWindows......40
4
7.1.1 InstalltheWebRAIDManagementSoftware.......................................................40
7.1.2 UninstalltheWebRAIDManagementSoftware...................................................44
7.2 Installing/UninstallingtheWebRAIDManagementSoftware‐Linux........................46
7.2.1 InstalltheWebRAIDManagementSoftware.......................................................46
7.2.2UninstalltheWebRAIDManagementSoftware..........................................................46
7.3
UsingtheWebRAIDManagementSoftware......................................................................46
5
SansDigitalTowerRAIDSATA6GtoeSATA6GPortMultiplier
Overview
SansDigital4bay/5bay/8BayTowerRAID6GStorage
SansDigital’sTowerRAID6Gportmultiplier(PM)StoragetowerutilizelatestSATA6Gtechnology,with6G
portmultiplier,usingasinglecablesconnectto4drives(TR4M6G)or5drives(TR5M6G),ortwocables
connectto8drives(TR8M6G).Bundledsecondgeneration6Gcontrollercardprovideshighbandwidth
usingPCIe2.0
x4connection.TowerRAID6GPMseriesprovideaneasytosetup,manageandhigh
performancestoragetowerforsmallormediumsizesbusiness,enterprises,videoentertainmentsand
videosurveillanceinprimaryorbackupstorageapplications.
SansDigital2ndGenerationSATA6Gb/sPCIE2.0RAIDController
AllmodelsbundledwithSansDigital’ssecondgenerationRocketRAIDCONTROLLER(RocketRAIDRR642L).Itis
anhighperformance,2portseSATA6Gb/sRAIDcontrollersupportingportmultiplier.Thecontrollerutilizea
PCIExpress2.0hostbusinterfacex4,SansDigital'sIndustryprovenRAIDengine,andsupportRAID
configurationsincluding0,1,5,
10andJBOD.
RocketRAID642LcontrollerarefullybackwardscompatiblewithSATA3Gb/sdevices,PCIExpress1.0and2.0
motherboards,andarecompliantwithoperatingsystemsincludingWindows8and7,MACandLinux.Each
RocketRAID642Lcontrollerdirectlysupportsupto2eSATAports,andupto20whenusedinconjunctionwith
portmultiplierstoragedevices,TR4M6G,TR5M6GandTR8M6G.
6
Chapter1‐FeaturesandSpecifications
HardwareSpecifications
PCIExpress2.0x4
4xSATA6Gb/sPorts
IndustrystandardSATA/eSATA/MiniSASconnectors
Directlysupports4SATAdevices/Upto20withportmultipliercapableenclosure
BackwardscompatiblewithSansDigitalSATARAIDCONTROLLER’s
LowProfile
Monitor,AlertsandLEDIndicators
HardDriveLEDIndicators(ActivityandFailed)
SMTPemailnotificationforeventsanderrorreporting
Alarm/Buzzeralertsfordrive/arrayfailure
AdvancedRAIDFeatures
RAID0,1,5,10,50,JBOD
RedundantRAIDConfigurationforArrayavailability
RAIDInitializationTypes‐Background,Foreground,QuickInitializationandKeepOldData
SpinDownIdleDisk
S.M.A.R.TSupport
AutoRebuildonsparedrive
HotPlugandHotSwap
support
Largerthan2TBdrivesupport
BootableRAIDArraysupport
WriteBackorWriteThroughCachesupport
UserfriendlyBrowserbasedManagementInterface
EasytouseBIOSconfigurationTool
LinuxCommandLineInterface(CLI)Scriptableconfigurationtool
Hotkey
(Ctrl+H)bootupRAIDmanagerviaBIOS
WebbrowserbasedRAIDmanagementsoftware(WebGUI)
CommandLineInterface(CLI)
OperatingSystemSupport
WindowsServer2012,2008,2003
Windows8,7,Vista
MajorLinuxDistributions
FreeBSD
MacOSX
7
Chapter2‐PhysicalSpecifications
Dimensions:
RocketRAID642L:79mmx67mmx1.5mm(3.12”x2.68”x0.06”)
EMI:
FCCPart15ClassBandCE
ThermalandAtmosphericCharacteristics:
WorkTemperatureRange:+5°C~+55°C
RelativeHumidityRange:5%~60%noncondensingStorageTemperature:‐20°C~+80°C
MTBF:920,585Hours
ElectricalCharacteristics:
PCIE 3.3V 12V
Power 4Wmax 1Wmax
8
Chapter3‐KitContents
Eachpackageshouldcontentthefollowings:
TR4M6G/TR5M6G/TR8M6Gstorageunit
RocketRAID642LControllercard
QuickInstallationGuide
SansDigitalSoftwareCD
LowProfileBracket
eSATA6Gb/scables(1pcforTR4M6GandTR5M6G,2forTR8M6G)
Ifmissinganyofthecontent,pleasecontact[email protected]
.
9
Chapter4‐HardwareDescriptionandInstallation
4.1RocketRAID642LHostAdapterboardlayout
4.2 InstallingtheRocketRAID642LHostAdapter
Note:MakesurethesystemispoweredoffbeforeinstallingtheRocketRAIDhostadapter.
TheRocketRAID642LCONTROLLERmayincludebothstandardandlowprofilebrackets.Itmaybe
necessarytoattachthelowprofilebracketinplaceofthestandardbracket,dependinguponthe
chassisdesign.
1. OpenthesystemchassisandlocateanunusedPCIE3.0/2.0/1.0(x4,x8,x16)slot.
2. RemovethePCIEslotcover.
3. GentlyinserttheRocketRAID642LcontrollerintothePCIEslot,andsecurethebrackettothesystem
chassis.
10
4. Afterinstallingtheadapter,attachtheharddisksorbackplaneenclosuretothehostadapterusingthe
appropriatecables.
Note:Manyserverlevelchassisincludeharddrivehotswapbays.Forthesesystemchassis,cables
areattachedtothechassisbackplane,ratherthandirectlytoeachindividualharddrive.
Consult
thechassismanualforproperinstallationprocedures.
5. Closeandsecurethesystemchassis.
4.3 VerifyingInstallation
Oncethehostadapterandharddriveshavebeeninstalledintothechassis,bootupthesystemtoverify
thatthehardwareisproperlyrecognized.
1. Poweronthesystem.Ifthesystemdetectsthepresenceoftheadapter,theRocketRAIDBIOSUtility
willbedisplayedduringbootup.
2. Press“Ctrl+H”keycombinationtoaccesstheRocketRAID642Ladapter’sBIOSUtility.
11
Chapter5‐RocketRAID642LBIOSUtility
TheRocketRAID642LcontrollerwilldisplayitsBIOSscreenduringthesystem'sbootprocess.TheBIOS
Utilitywilldisplayinformationaboutharddrivesattachedtotheadapter.Makesureallattacheddrives
aredetectedbythisutility.Ifanyoftheharddriveisnotdetected,powerdownthesystemand
check
thepowerandcableconnections.
Press“Ctrl+H”keycombinationtoaccesstheRocketRAID642Ladapter’sBIOSUtility.
5.1 BIOSSettingsOverview
TheRocketRAID642LcontrollerBIOSutilityisaninterfacethatprovidesmanagementcommandsand
controllerrelatedsettings.
5.2 UsingtheBIOSUtility
ThefollowingkeysareutilizedbytheRocketRAID600L600LSBIOSutility:
ArrowkeysUsethesetomovebetweendifferentmenuitems.
EnterOpentheselectedtoolbarcommand/executetheselectedcommand.
EscMovebacktothepreviousmenu,canceltheselectedoperation,orexittheBIOSUtility.
12
5.3 BIOSCommands
Create: ThiscommandisusedtoopentheRAIDCreationmenu.
Delete: ThiscommandwilldeletetheselectedRAIDarray.
Add/Remove Thiscommandisusedtoassignharddiskstofunctionassparedisks.Thecontrolleris
Spare capableofusingsparediskstoautomaticallyrebuildbrokenorfaultedRAIDarrays.
Settings Thiscommandopensthesettingsmenu(Toselectingthebootdisk/array,staggered
drivespinupetc.)
View ThiscommandisusedtoviewharddiskandRAIDinformation.
Initialize ThiscommandisusedtopreparedisksforusewithRAIDarrays.Disksmustbe
initializedbeforetheycanbeusedtocreatearrays.
13
14
5.4 CreatingRAIDArrays
InitializingDisks:
Before creating a RAID array, the disks must be initialized. Disk initialization writes necessary RAID
configuration information to the hard disks. Select the Initialize command from the toolbar, and press
Enterkey.
Highlight the target disks using the arrow keys, then press the Enter key. A numeral will be displayed
beforeeachselecteddisk.Oncealltargetdiskshavebeenselected,pressESCkey.Theutilitywilldisplaya
warning,andaskyoutopressY(yes)toinitialize,orN(no)to
cancel.Onceinitialized,thesediskscanbe
usedtocreateRAIDarrays.Thesediskswillbedisplayedas“Initialized”(underStatus).
Warning:Initializationwilldestroyallpre‐existingdataontheselectedharddisks.Onlyinitialize
disksthatdonotcontaincriticaldata.
CreateArrays:
SelectCreatefromthetoolbarandpressEnterkey.
1. UsethearrowkeystoselecttheRAIDlevelandpressEnterkey.
2. UsethearrowkeystohighlighttheArrayNameoptionandpressEnterkey.Thearraynamedialogue
15
boxwillappear.UsethekeyboardtoinputanewArrayName,andpresstheEnterkey.
16
Note:TheArrayNamecommandisoptionalitisnotnecessarytonamethearray.Thearraycanbe
namedatalatertime,andthenameofthearraycanbechangedatanytime.
3. OntheCreatemenu,usethearrowkeysto highlight the SelectDevicesitem and pressEnterkey.A
devicelistwillappear,anddisplayallavailableharddiskdrives.
4. Highlightthetargetdisksthatyouwanttouse,andpressEnterkeytoselectthem.Anumeralwillbe
displayed before each selected disk. This number designates disk order. After all of the disks have
beenselectedandpresstheESCkeytoreturntotheCreateMenu.
5. Next,Usethe↓arrowkeytohighlighttheCapacity(GB)optionandpressEnterkey.Thetotal
17
18
availablecapacitywillbedisplayed.PressEnterkeyifyouwishtouseallavailablespace.Ifyouwishto
reservediskspaceforadditionalarrays/singledisks,usethekeyboardtoinputtheamountofspace(in
GB)youwishtosetasideforthisparticulararray,andpressEnterkey.
Note:Multiplearrayscanbecreatedusingthesamesetofharddiskdrives.TheCapacityoptionallows
youtosetasidediskspacethatbe usedtocreateanotherarray,setasasparedisk,orpartitionedto
actasasingledisk(bytheoperatingsystem).
6.ForredundantRAIDarrays(RAID5,50),selecttheCachePolicy:
WriteBackProvideshigherwriteperformanceforredundantRAIDarrays.Dataisatriskwhenthere
isapowerfailure,systemkernelpanicandunrespondingabnormalconditions.
WriteThroughWritesdirectlytothedisks(mayreducetheriskofdatalossduringacriticalfailure,
butatthecostoflowerperformance).
19
7. SectorSizeAlsoknownas“VariableSectorSize”.Usethisoptionifyouareusinganolder32bit
Windowsoperatingsystem.Thisallowsolderoperatingsystemstosupportvolumesover2TBin
size.Donotuseiftheoperatingsystemalreadysupportslargevolumes(suchasGPT).
8. Tocompletethecreationprocedure,usethearrowkeytohighlighttheStartCreationitemand
pressEnterkey.
TheWindowwillshow2optionsifcreateRAID5:BackgroundInitializeandNoinitialization.
Background TheRAIDarrayisaccessiblewhilediskinitializationisbeingperformed.
Initialization: Thisoptionwilldeleteallcontentonthedisks.
Theinitializationtimewillbelongerwhencomparedto"Foreground"butthe
logicaldrivescanbeusedduringtheinitializationprocess.
20
/