2
© Copyright 2017 Zoeller
®
Co. All rights reserved.
LIMITED WARRANTY
HELPFUL HINTS FOR EASY INSTALLATION
DO’S AND DON'T’S FOR INSTALLING UNIT
DO’S AND DON'T’S, continued
Manufacturer warrants, to the purchaser and subsequent owner during
the warranty period, every new product to be free from defects in material
and workmanship under normal use and service, when properly used and
maintained, for a period of one year from date of purchase by the end user, or
18 months from date of original manufacture of the product, whichever comes
rst. Parts that fail within the warranty period, one year from date of purchase
by the end user, or 18 months from the date of original manufacture of the
product, whichever comes rst, that inspections determine to be defective
in material or workmanship, will be repaired, replaced or remanufactured
at Manufacturer's option, provided however, that by so doing we will not be
obligated to replace an entire assembly, the entire mechanism or the complete
unit. No allowance will be made for shipping charges, damages, labor or
other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any
material or product that has been disassembled without prior approval of
Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident
or uncontrollable act of nature; that has not been installed, operated or
maintained in accordance with Manufacturer's installation instructions; that has
been exposed to outside substances including but not limited to the following:
sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil,
gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels
or feminine sanitary products, or any other abusive entity, etc. in all pumping
applications. The warranty set out in the paragraph above is in lieu of all other
warranties expressed or implied; and we do not authorize any representative or
other person to assume for us any other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky USA
40211, Attention: Customer Support Department to obtain any needed repair
or replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF
EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY
OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY
SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some jurisdictions do not allow limitations on the duration of an implied
warranty, so the above limitation may not apply to you. Some jurisdictions do
not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you.
This warranty gives you specic legal rights and you may also have other
rights which vary from jurisdictions to jurisdictions.
1. Read all instructions before beginning installation.
2. Be sure the oor is level within 1/8" (3 mm).
3. Install vent pipe seals with ange side of seal on outside of lid.
4. Use soapy water to lubricate all seals to aid installation.
5. Install rubber coupling/union in vent line to aid disassembly.
6. Do not over-torque toilet mounting screws.
7. Do not use an automatic plumbing vent device.
8. Obtain model number and date code, and record information in the
space provided on the front of this manual. Refer to this information
when calling the factory.
1. DO read all installation material with the unit.
2. DO inspect unit for any visible damage caused by shipping. Contact
dealer if unit appears to be damaged.
3. DO clean all visible debris from the unit.
4. DO always disconnect pump from power source before handling. DO
always connect to a separately protected and properly grounded ground
fault protected circuit. DO NOT ever cut, splice or damage power cord. DO
NOT carry or lift pump by its power cord. DO NOT use an extension cord.
5. DO install a ball or gate valve and a union in the discharge line
downstream of the check valve.
6. DO test pump immediately after installation to be sure that the system
is working properly.
7. DO review all applicable governing codes and verify that the installation
conforms to each of them.
8. We DO NOT recommend this product be connected to utilities other than
those found in a normal bathroom application. Washing machines and
dishwashers are examples of equipment that we DO NOT recommend.
9. DO inspect and test system for proper operations at least every 3 months.
1. The Qwik Jon
®
Ultima is tted with a specially-designed grinder pump
and is capable of pumping fecal matter, toilet paper and sanitary articles
which may be accidentally dropped into the toilet. It is not recommended
to ush such foreign objects as they might clog the sanitary sewer.
2. Risk of injury. Cutter system located on intake of the pump is sharp. Keep
hands and ngers clear.
3. Check to be sure your power source is adequate to handle the amperage
requirements of the motor as indicated on the pump or unit I.D. tag.
4. All plumbing (discharge and vent lines) must be installed to meet governing
codes. Unit must be vented. Do not use an automatic plumbing
vent device.
5. Maximum operating liquid temperature must not exceed 130°F (54°C).
6. Do not use cleaning products containing bleach in the toilet tank, toilet or
attached xtures as they will degrade the pump seals.
7. Risk of explosion. Do not use the pump for ammable liquids, such as
diesel oil, petrol or similar liquids.
8. Installation and maintenance of this appliance is not intended for persons
(including children) with reduced physical, sensory or mental capabilities, or
lack of experience or knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for
their safety.
1. Repair and service should be performed by an Authorized Service Station
only (consult factory).
2. Recommended for installations with total dynamic head up to 20' (6 m).
Consult factory if installation is above 13' (4 m) vertical height. The mini-
grinder pump is designed for use in Qwik Jon
®
Ultima units only. It is not
designed for use in any other application.
3. Pumps with the “UL” mark and/or the “US” mark are tested to UL Standard
UL778. CSA Certied pumps are certied to CSA Standard C22.2 No.
108.
4. All xtures connecting to the system must be on the same oor level.
SEE BELOW FOR
LIST OF CAUTIONS
CAUTIONS, continued
9. Risk of burn. Pump contains oil which becomes pressurized and hot
when operating. Allow 2½ hours after disconnecting before attempting
service.
SEE BELOW FOR
LIST OF NOTES
NOTES