Redi Swing 29VCPNP04876 Installation guide

Type
Installation guide

This manual is also suitable for

RDQCI5288 Rev. 0 Page 1 Cered 06/01/2016
SERIES: 2000
CONFIGURATION: Door-Panel
MOUNTING PACKAGE: No header, glass-to-glass hinges,
u-channel on panel(s) and or return(s)
bottoms, wall clamps on panel(s) and or
return(s) wall sides, support bars from
walls to panels-returns
Redi Swing
TM
...Opening Doors to Stunning Showers!
TM
INSTALLATION INSTRUCTIONS
tile
redi
®
redi
DOOR
®
FRAMELESS INLINE DOOR
SERIES: 2000
CONFIGURATION: Door-Panel
MOUNTING PACKAGE: No header, glass-to-glass hinges,
u-channel on panel(s) and or return(s)
bottoms, wall clamps on panel(s) and or
return(s) wall sides, support bars from
walls to panels-returns
Redi Swing
TM
...Opening Doors to Stunning Showers!
TM
INSTALLATION INSTRUCTIONS
tile
redi
®
redi
DOOR
®
FRAMELESS INLINE DOOR
SERIES:
CONFIGURATION:
MOUNTING PACKAGE:
2900V
Door-Panel
No header, oset pivot hinges, u-channel on
panel boom and side
Redi Swing
RDQCI5288 Rev. 0 Page 2 Cered 06/01/2016
Installation Notes:
Proper blocking is required for every Heavy Glass unit prior to installation. At minimum 2x4
blocking is required at the location of any structural member of the unit including, but not lim-
ited to: hinges, clamps, and header brackets. All fasteners at these locations are required to
be installed into the blocking.
A minimum of 1 1/4” thread engagement is required of all fasteners into the blocking at these
locations. Depending on the application the customer maybe required to supply the proper
fasteners to ensure adequate engagement.
U-Channel maybe installed using wall plugs where no backing is found.
Use caution to not pierce plumbing or electric lines while installing door hardware.
Cover the drain with tape prior to installation to prevent loss of small parts.
Unpack your unit carefully and inspect for freight damage. Lay out and identify all parts using
the instruction sheet as a reference. Before discarding the carton, check to see that no small
hardware parts have fallen to the bottom of the box. If any parts are damaged or missing, refer
to the description noted in the instructions when contacting your dealer for replacements.
Maintenance:
Tools:
To install your New Shower Enclosure, you may need the following:
Pencil
Low Tack Tape
Tape Measure
4’ & 6’ Levels
#2 Phillips Screwdriver
Hack Saw
Caulk Gun
Clear Silicone Caulk
Suction Cups
Drill
1/8” & 3/16” Drill Bit
Center Punch
Files
This unit is best installed by two people.
Handle the glass panels carefully and protect the edges. Safety tempered glass is very re-
sistant to breakage, but the sharp corners of the panels can damage tile and flooring surfaces.
The glass can break if unequal pressure is applied during installation.
Please wear safety glasses whenever drilling or cutting. When drilling holes in ceramic tile or
marble, use a center punch and hammer to carefully break the glazed surface to prevent skid-
ding when drilling.
NOTE: Tempered glass cannot be cut.
Safety Notes:
Caring for Redi Clear™ Treated Glass
In order to maintain your ten year warranty, please follow these care instructions:
Once or twice a week, wipe down your shower door to remove body oils, soaps and shampoos from the surfaces.
The glass should be cleaned every few weeks using a damp microfiber cloth and a mild detergent or soap to
remove any soap scum and grime from the glass. Do not use paper towels or any abrasive tool to clean the
surface. The sealed surface is warranted with regular maintenance and without the use of any harsh chemicals or
detergents.
Caring for Non-Treated Glass
After each use, rinse with water and wipe down your enclosure with a soft cloth/towel or squeegee to maintain that
like-new look. The glass should be regularly cleaned using a damp microfiber cloth and a mild detergent or cleaner
to remove any soap scum and grime from the glass. We recommend Lysol Bathroom Cleaner as safe for shower
doors, but please test any commercial cleaning solutions on an inconspicuous area before applying to the entire
enclosure. Be sure to rinse all surfaces completely and wipe dry. Never use any abrasive material or harsh
chemicals to clean surfaces and do not allow cleaners to soak on surfaces.
RDQCI5288 Rev. 0 Page 3 Cered 06/01/2016
ITEM DESCRIPTION QT Y.
A 1-1/2” DEEP U-CHANNEL 1
B 1/2” ROLL-IN GLAZING GASKET 2
C SUPPORT BAR* 1
D FIXED PANEL GLASS 1
E TOP PIVOT HINGE** 1
F DOOR GLASS 1
G STRIKE-VINYL 1
H KNOB 1
I 3/8” VINYL SWEEP 1
J BOTTOM PIVOT HINGE** 1
K WALL PLUG 16
L STRIKE JAMB SCREW #8 X 1-1/2” 16
M 1-1/2” DEEP U-CHANNEL 1
N SETTING BLOCKS (1/2”) 2
O 1/2” ROLL-IN GLAZING GASKET 2
AA PANEL CLAMP PLATE
BB CLEAR VINYL
CC PANEL CLAMP SCREWS
DD DOOR CLAMP PLATE
EE DOOR CLAMP SCREWS
FF HANDLE BODY
GG CLEAR WASHER
HH HANDLE STUD
PARTS LIST
*Support bar only included if necessary.
**Top and boom indicated for le hinged doors. Hinge locaons are reversed for right hinged doors
RDQCI5288 Rev. 0 Page 4 Cered 06/01/2016
EXPLODED VIEW
RDQCI5288 Rev. 0 Page 5 Cered 06/01/2016
EXPLODED VIEW
RDQCI5288 Rev. 0 Page 6 Cered 06/01/2016
Page 6
Measurements
Cered 09/02/2015
CENTERLINE MEASUREMENT
Our units are ordered based on nished centerline measurements of the locaon of
the unit.
To ensure a proper t, a centerline should be found and marked as shown below. To
start, lightly mark a connuous unit centerline on the threshold.
Next, mark a connuous unit centerline up each wall, starng where the threshold
centerline meets the wall. Use a level to ensure the wall centerline is plumb and
straight. The wall centerlines you mark should be a minimum of the unit height from
the threshold
Centerline is a term used to describe the center or mid-point of the unit. The
posion of the unit centerline can be located anywhere in the width of the
threshold, as long as adequate structure exists beneath the centerline for fastening
and the outer edges of the unit will not overhang the threshold. The most common
unit centerline posion is the middle of the threshold.
Centerline
Centerline
Unit Cross Secon
Page 6 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 7 Cered 06/01/2016
Page 7
Installaon
Cered 09/02/2015
HORIZONTAL U-CHANNEL
Find the U-Channel (M). First, the channel needs to be cut to length. Determine the
width of your units Fixed Panel (D) and cut the U-Channel (M) 2-1/2” shorter than
the width of the glass.
Example: 18” Panel width - 2.5” = 15.5” Channel length
Drill two 3/16” holes approximately 3” from the ends.
Posion the U-Channel (M) on the marked centerline of your threshold and slide it
against the side wall. Mark each hole posion on the threshold.
Remove the U-Channel (M) and drill 3/16” diameter holes approximately 1-1/2” deep
at the marked locaons.
Insert a small amount of silicone into each drilled hole, then insert a Wall Plug (K) into
each hole. Carefully cut the heads o each wall plug with a razor blade and posion
the U-Channel (M). You must secure U-Channel before the silicone starts to cure.
Secure the U-Channel (M) with the Screws (L), do not over-ghten.
1
VERTICAL U-CHANNEL
Find the U-Channel (A). To cut the channel, determine the height of your unit and cut
the U-Channel (A) 1-1/2” shorter than the unit height.
Example: 76” unit height - 1.5” = 74.5” channel length
Drill two holes approximately 6” from the top and boom of the U-Channel (A) and a
third hole in the middle.
Hold or tape the U-Channel (A) against the wall and follow instrucon for horizontal
U-Channel (M) to secure to wall.
2
Page 7 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
*If using a Tile Ready® brand shower pan, please refer to the attached Tile Ready® Brand Shower Pan
Installation Addendum for important instructions to ensure a leak-proof installation.
*
RDQCI5288 Rev. 0 Page 8 Cered 06/01/2016
Installaon
Cered 09/02/2015
Page 8
BOTTOM HINGE
Find the Boom Hinge (J) and place it on the threshold against the horizontal
U-Channel (M). Make sure that the opening for the hinge matches the U-Channel (M)
as shown below. Mark holes on the threshold then remove the Boom Hinge (J) and
drill 3/16” diameter holes approximately 1-1/2” deep (same as U-Channel (M & A)
holes in steps 1 & 2).
Follow the same steps as securing the U-Channel (M & A) to secure the Boom Hinge
(J) to the threshold.
3
Side View
Ensure hinge is in line with
U-Channel as shown
View from outside shower
Page 8 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 9 Cered 06/01/2016
Page 9
Installaon
Cered 09/02/2015
GLASS PANEL
Find the Fixed Panel Glass (D) and Seng Block (1/2”) (N). Place the Seng Block
(1/2”) (N) on the U-Channel (M) then stack addional 1/16” or 1/8” seng blocks if
necessary to make the Fixed Panel Glass (D) plumb with the wall and level with the
oor. Do not place seng blocks over screw heads.
Aer nding the correct combinaon of seng blocks, the Fixed Panel Glass (D) is
ready to be mounted. Take the Clear Vinyl (BB) and place it in the hinge as shown
below. Use the alcohol pad (or rubbing alcohol) to clean the secon of glass that will
go into the Boom Hinge (J) opening. Loosen the Panel Clamp Screws (CC), mount
the Fixed Panel Glass (D) so it sits inside the U-Channel (M) and Boom Hinge (J),
then ghten the Panel Clamp Screws (CC).
The Fixed Panel Glass (D) will sll be loose and wobble inside the U-Channel (M), this
is ok for now.
4
Clear Vinyl in
hinge channel
Page 9 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 10 Cered 06/01/2016
Installaon
Cered 09/02/2015
Page 10
GLAZING GASKET
Spray soapy water on the glass near the U-Channel (M). Then insert the Glazing
Gasket (O) as shown in the gure below. Start at the wall and push the glazing into
the gap unl you reach the Boom Hinge (J) and cut o any extra. Insert one side
completely rst, and then the other.
When inserng the wall Glazing Gasket (B), start from the boom and work your way
up, any extra glazing scking out of the top can be cut o with scissors. Taping the
glazing to the top is helpful for holding it upright while inserng. Using a block of
wood may be helpful for inserng the glazing.
5
TOP HINGE
Find the Top Hinge (E) and loosen the Panel
Clamp Screws (CC). Use an alcohol swab (or
rubbing alcohol) to clean the glass where the
hinge will sit. Place the Clear Vinyl (BB) in the
hinge channel like the boom hinge.
Place the Top Hinge (E) on the notches in the
top of the Fixed Panel Glass (D) and ghten
the Panel Clamp Screws (CC).
6
Page 10 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 11 Cered 06/01/2016
Page 11
Installaon
Cered 09/02/2015
DOOR GLASS
To mount the Door Glass (F), loosen the Door Clamp Screws (EE) on both the Top
Hinge (E) and Boom Hinge (J).
Next, clean the area the Door Glass (F) contacts the hinges with rubbing alcohol.
Carefully slide the Door Glass (F) into the open hinge slots and ghten the Door
Clamp Screws (EE).
If the Door Glass (F) will not t into the hinges, slightly loosen the Panel Clamp
Screws (CC) on the top hinge to adjust the hinge posion to t the Door Glass (F). Be
sure to reghten Panel Clamp Screws (CC) aer door installaon if they were loos-
ened.
Slowly close the Door Glass (F), adjusng as required to get a 3/16” gap at the wall.
Be sure the Door Clamp Screws (EE) are securely ghtened when adjusng is com-
plete.
7
Page 11 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 12 Cered 06/01/2016
Installaon
Cered 09/02/2015
Page 12
SWEEP AND STRIKE-VINYL
The Sweep (I) and Strike-Vinyl (G) help reduce leakage in your frameless unit and
protect the door from damage. Before installaon, you may be required to cut the
Sweep (I) and Strike-Vinyl (G) to your unit width and height.
To install, clean the wall with an alcohol swab where the vinyl will sit. Find the Strike-
Vinyl (G) and peel o the protecve strip. Adhere the vinyl to the wall where the door
is closed. The vinyl prevents the door from closing too far.
Next, nd the Sweep (I). Slide the piece onto the boom of the Door Glass (F) with
the wing facing inwards as shown in the gure. Adjust the Sweep (I) so that it contacts
the threshold. Depending on how closely the sweep contacts your threshold, you may
also need to trim the sweep legs for a proper t.
To prevent the Sweep (I) from moving and to reduce water leakage into the sweep,
run a bead of silicone on the inside of the door between the sweep and glass.
8
HANDLE
Find the Handle (H) and unscrew the two secons. Insert the Handle Body (FF) and
the Stud (HH) into the hole in the Door Glass (F) and screw the other side of the
handle onto the Stud (HH).
9
WALL
3/16”
Sweep legs
Page 12 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 13 Cered 06/01/2016
Page 13
Installaon
Cered 09/02/2015
SEALING
Run a bead of silicone along the interior edges of the U-Channels (M & A) . Run the
silicone between the threshold and u-channels as shown.
You must wait for the silicone to fully cure before
using your shower. Check tube for curing me.
10
Page 13 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 14 Cered 06/01/2016
Installaon
Cered 09/02/2015
Page 14
SUPPORT BAR
In some applicaons, the unit requires installing a support bar to make the enclosure
safe. The support bar aaches to the panel and screws into the wall. Note: The
support bar as packaged is not cut to length.
Support bars are included with every enclosure they are required on. To install, nd
the Panel Mount (NN) and loosen the Panel Clamp Screw (MM) and place the panel
mount on the glass panel approximately 6” away from the edge of glass as shown.
Next, measure from the center of the Panel Mount (NN) to the wall. Note the
measurement and mark a hole at that distance on the return wall. Drill a 3/16”
diameter hole approximately 1-1/2” deep on your mark.
Insert a wall plug and cut o the head with a razor blade. Fasten the Bushing (QQ) to
the wall using the Bushing Screw (RR). Loosen the Bushing Clamp Screw (OO), place
the Wall Mount (II) onto the bushing, and make it ush against the wall.
Measure approximately the distance between the Wall Mount (II) and Panel Mount
(NN) where the Support Bar (JJ) will sit. Cut the support bar about 1/2” longer than
your measurement.
To mount the bar, the Panel Mount (NN) needs to be removed and both Bar Screws
(KK & PP) need to be loosened. Remove the Panel Mount (NN) and place one end of
the support bar into the Wall Mount (II). Slide the Panel Mount (NN) onto the
Support Bar (JJ) and posion the angle adjuster so it ts onto the panel. It is ok if the
Panel Mount (NN) is not exactly 6” from the edge. Finally, ghten all screws.
11
Measure
6”
Repeat Measure
Drill 3/16” Hole
Page 14 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 15 Cered 06/01/2016
Page 15
Installaon
Cered 09/02/2015
II
JJ
KK
LL
MM
NN
OO
PP
QQ
II 45° Wall Mount
JJ Support Bar
KK Bar Screw
LL Angle Adjustment Screw
MM Panel Clamp Screw
NN Panel Mount
OO Bushing Clamp Screw
PP Bar Screw
QQ Bushing
RR Bushing Screw
RR
Page 15 of 15 Date Certified: 06/21/2016
RDQCI5288 Rev. 0
RDQCI5288 Rev. 0 Page 16 Cered 06/01/2016
Tile Ready® Brand Shower Pan Installaon Addendum
SPECIAL INSTRUCTIONS FOR REDI DOOR® ENCLOSURE INSTALLATIONS WITH TILE READY® BRAND SHOWER
PANS
Designated screw pack for Tile Ready® Brand Shower Pans:
For Redi Door® enclosure installaons with a Tile Ready® brand shower pan, a special screw pack containing
eight (8) #8x¾” pan-head screws is included with your door. These #8x¾”screws replace curb screws included
in the main hardware package, and their use is mandatory. Set drill stop at 5/8” to avoid piercing the shower
pan curb.
FAILURE TO USE THE CORRECT SCREWS & FOLLOW THESE INSTRUCTIONS WILL VOID THE TILE READY® BRAND
SHOWER PAN LIMITED WARRANTY.
1. Align the u-channel in the proper posion on the curb/entrance
2. Mark and drill a 3/16” hole through the u-channel
3. Transfer this locaon to the le and drill a 3/16” hole through the le and grout only 4. Insert a dab of
silicone caulking into the hole
5. Put the u-channel in place.
6. Using the provided #8 x ¾” pan-head screw, fasten the u-channel in place on the curb.
Special instrucons for Tile Ready® Brand Barrier Free entrances:
For Redi Door® enclosure installaons on a Tile Ready® brand BARRIER FREE entrance, only silicone seal should
be used to aach enclosure parts to the shower pan entrance. No screws or nails should be used to install
enclosure hardware into the shower pan entrance.
THE USE OF SCREWS OR NAILS IN THE BARRIER FREE ENTRANCE WILL VOID THE TILE READY® BRAND SHOWER
PAN LIMITED WARRANTY.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Redi Swing 29VCPNP04876 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI