DATE: 04/15/11 BULLETIN NO:
TITLE/ PRODUCT NAME: EPP201_EPP360 Wiring Change
PRIORITY:
HIGH
RATING:
_
X
_ DIRECTIVE _
X
_ ALERT
(Action is Required) (Potential Problem)
_
_ INFORMATION _ _ PRODUCT IMPROVEMENT
(Action is Optional) (Enhanced Product)
_
_ General Distribution _
_ Business Confidential
(Unrestricted) (Restricted Distribution)
PRODUCT SERIES / MODEL: EPP 201 and EPP360 Power Supplies.
This Service Bulletin is for all EPP201s and EPP360s before the following Serial #’s:
ESAB NA Manufactured Units-Serial Number PD-K115009
ESAB Laxa Manufactured Units-Serial Number 015-118-xxxx.
SUMMARY:
The CC-11 will send the Coolant Level and Coolant Flow switch inputs to the EPP
Power Source. The EPP at times will not output these signals back to the CNC due
to the failure of opto islolators in the EPP’s PCB3.