Beta 1760/IR1600 Operating instructions

Category
Measuring, testing & control
Type
Operating instructions

This manual is also suitable for

IT
TERMOMETRO AD INFRAROSSI SENZA CONTATTO
MOD. 1760 / IR1600
NON-CONTACT INFRARED THERMOMETERS
MOD. 1760 / IR1600
EN
TERMÓMETROS INFRARROJOS SIN CONTACTO
MOD. 1760 / IR1600
THERMOMÈTRES INFRAROUGES SANS CONTACT
MOD. 1760 / IR1600
FRAES
CONTACTLOZE INFRARODE THERMOMETERS
MOD. 1760 / IR1600
KONTAKTFREIES INFRAROT-THERMOMETER
MOD. 1760 / IR1600
DENLPL
BEZKONTAKTOWY TERMOMETR IR
MOD. 1760 / IR1600
Beta 1760_IR1600.indd 1 14-04-2008 14:03:36
19
EN
EN
NON-CONTACT INFRARED THERMOMETERS
MOD. 1760 / IR1600
TABLE OF CONTENTS:
Introduction .............................................................................................................................20
Features ...................................................................................................................................20
Wide range of applications
......................................................................................................21
Safety .......................................................................................................................................21
Distance & Spotsize
................................................................................................................22
Specications ...........................................................................................................................23
Front panel description
............................................................................................................25
Indicator ...................................................................................................................................26
Buttons .....................................................................................................................................27
Measurement operation
...........................................................................................................30
Battery replacement
.................................................................................................................31
Notes ........................................................................................................................................31
Maintenance & clearing
..........................................................................................................35
Beta 1760_IR1600.indd 19 14-04-2008 14:03:42
20
EN
EN
INTRODUCTION
Thank you for your purchase of the IR Thermometer. This equipment is capable of non-contact
(infrared) temperature measurements at the touch of a button. The built-in laser pointer increa-
ses target accuracy while the backlight LCD and handy push-buttons combine for convenient,
ergonomic operation.
The Non-contact Infrared Thermometers can be used to measure the surface temperature of objects
that cannot be measured by a traditional (contact) thermometer (eg moving object, the surface
carries an electrical current, or the objects are uneasy to be touched.)
Proper use and care of this meter will provide years of reliable service.
FEATURES:
Precise non-contact measurements
High distance-to-target ratio measures smaller surface areas at greater distances
Widest temperature range
Unique at surface, modern housing design
Built-in laser pointer
Automatic Data Hold
℃/℉ switch
Emissivity digitally adjustable from 0.10 to 1.0
Beta 1760_IR1600.indd 20 14-04-2008 14:03:42
21
EN
EN
MAX,MIN,DIF, AVG temperature displays
Backlight LCD display
Built-in laser pointer
Automatic selection range and Display Resolution 0.1ºC(0.1ºF)
Trigger lock
Set high and low alarms
WIDE RANGE OF APPLICATIONS:
Food preparation, Safety and Fire inspectors, Plastic molding, Asphalt, Marine and Screen printing,
measure ink and Dryer temperature, HVAC/R, Diesel and Fleet maintenance.
SAFETY
Use extreme caution when the laser beam is turned on.
Do not let the beam enter your eye, another person’s eye or the eye of
an animal.
Be careful not to let the beam strike your eye from a reective surface.
Do not allow the laser light beam to impinge on any gas which can
explode.
Beta 1760_IR1600.indd 21 14-04-2008 14:03:42
22
EN
DISTANCE & SPOT SIZE
As the distance (D) from the object increases, the spot size (S) of the area measured by the unit
becomes larger. The relationship between distance and spot size is below. The focal point for each
unit is 914mm (36”). The spot sizes indicate 90% encircled energy.
Picture:
MODEL:
1760/IR1600
Distance (D) / to spot size (S)
Distance(D) to Spot Size(S)
inch
16mm
Sensor Beam
mm
D
18@900
6.0@300
30@1500
0.72@36
0.24@12
1.2@60
S
MODEL:8858/8859 D:S=50:1
Laser Beam
Fig.1
Beta 1760_IR1600.indd 22 14-04-2008 14:03:42
23
EN
SPECIFICATION
Model Temperature range D:S
1760/IR1600 -50 to 1600 °C (-58 to 2912℉) 50:1
Display resolution 0.1º up to 2000º,1ºover 2000º
Accuracy for targets:
Assumes ambient operating temperature of 18 oC to 28 oC (64℉ to 82 ℉), less than 80 % RH.
-50 to -20℃(-58 to -4℉): ±5 °C(±9℉)
-20 to 200℃(-4 to 392℉): ± 1.5% of reading + 2℃(±3.6℉);
200 to 538℃ (392 to 1000℉): ± 2.0% of reading +2℃(±3.6℉);
538 to 1300℃(1000 to 2372℉): ± 3.5% of reading ± 5℃(±9℉)
1300℃to 1600℃(2372 to 2912℉): ± 3.8% of reading ± 5℃(±9℉)
Response time less than 1 second
Spectral response 8~14µm
Emissivity Digitally adjustable from 0.10 to 1.0
Over range indication LCD will show “-0L”,”0L”
Beta 1760_IR1600.indd 23 14-04-2008 14:03:42
24
EN
Polarity Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity
Diode laser output <1mW,Wavelength 630~670nm,
Class 2(II) laser product
Operating temp. 0 to 50℃(32 to 122℉)
Storage temp. –20 to 60℃ (-4 to 140℉)
Relative humidity 10%~90%RH operating, <80%RH storage
Power supply 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
Weight 290g (10.2 oz.)
Size 100 x 56 x 230mm (3.9 x 2.2 x 9.0”)
Safety “ CE ” Comply with EMC
Note:
Accuracy: Given at 18 to 28 °C (64 to 82 ℉), less than 80 % RH.
Field of View: Make sure that the target is larger than the unit’s spot size. The smaller the target,
the closer you should be to it. When accuracy is critical, make sure the target is at least twice
as large as the spot size.
Beta 1760_IR1600.indd 24 14-04-2008 14:03:42
25
EN
FRONT PANEL DESCRIPTION
IR sensor
Laser pointer beam
LCD Display
Down button
Up button
Mode button
Laser/backlight button
Measurement Trigger
Handle Grip
Battery Cover
1
2
3
4
5
6
7
8
9
10
1
2
3
4
7
8
5
6
9
10
Beta 1760_IR1600.indd 25 14-04-2008 14:03:43
26
EN
1
2
3
4
7
8
5
6
9
10
INDICATOR
Data hold
Measuring indication
Emissivity symbol and value
Low battery, lock and laser” on” symbols
Backlight “on” symbol
℃/℉ symbol
High alarm and low alarm symbol
Temperature values for the MAX, MIN, DIF, AVG
HAL and LAL.
Symbols for EMS MAX, MIN, DIF, AVG, HAL and
LAL.
Current temperature value
1
2
3
4
5
6
7
8
9
10
Beta 1760_IR1600.indd 26 14-04-2008 14:03:44
27
EN
BUTTONS
Up button (for EMS, HAL, LAL)
MODE button (for cycling through the mode loop)
Down button (for EMS, HAL, LAL)
Laser/Backlight on/off button (pull trigger and press button to activate laser/backlight)
1
2
3
4
MODE
1
2
3
4
Beta 1760_IR1600.indd 27 14-04-2008 14:03:44
28
EN
MODE Button Function
The infrared thermometer measures Maximum (MAX), Minimum
(MIN), Differential (DIF), and Average (AVG) temperature each
time you take a reading. This data is stored and can be recalled
with the
MODE button until a new measurement is taken. When
the trigger is pulled again, the unit will begin measuring in the last
mode selected.
Pressing the
MODE button also allows you to access the High
MODE Alarm (HAL), Low Alarm (LAL),Emissivity (EMS). Each
time you press
MODE ,you advance through the mode cycle.
The diagram shows the sequence of functions in the
MODE
cycle.
EMS
MAX
MIN
DIF
AVG
HAL
LAL
MODE
Beta 1760_IR1600.indd 28 14-04-2008 14:03:44
29
EN
1
2
3
Switching C/F, LOCK ON/OFF and SET ALARM
C°/F°
Lock ON/OFF
Set Alarm
1
2
3
Select the temperature units (°C or °F) using the °C/°F switch
To activate the alarms, slide the bottom switch SET ALARM
right.
To set values for the High Alarm (HAL), Low Alarm (LAL)
and Emissivity (EMS), rst activate the display by pulling the
trigger or pressing the MODE button, then press the MODE
button until the appropriate code appears in the lower left cor
-
ner of the display, press the UP and down buttons to adjust the
desired values.
To lock the unit on for continuous measurement, slide the middle
switch LOCK ON/OFF right. If the trigger is pulled while the
unit is lock on, the laser and backlight will turn on if they have
been activated. When the unit is locked on, the backlight and laser
will remain on unless it is turned off using the Laser/Backlight
button on the keypad.
Beta 1760_IR1600.indd 29 14-04-2008 14:03:45
30
EN
MEASUREMENT OPERATION:
Hold the meter by its Handle Grip and point it toward the surface to be measured.
Pull and hold the Trigger to turn the meter on and begin testing. The display will light if the
battery is good. Replace the battery if the display does not light.
While measuring, the SCAN display icon will appear in the upper left hand corner of the
LCD.
Release the Trigger and the HOLD display icon will appear on the LCD indicating that the
reading is being held.
The meter will automatically power down after approximately 7 seconds after the trigger is
released.(Unless the unit is locked on)
Note: Measurement considerations
Holding the meter by its handle, point the IR Sensor toward the object whose temperature is to be
measured. The meter automatically compensates for temperature deviations from ambient tempe
-
rature. Keep in mind that it will take up to 30 minutes to adjust. Where wide ambient temperatures
are to be measured followed by high temperature measurements, some time (several minutes) is
required after the low (and before the high) temperature measurements are made.
This is a result of the cooling process, which must take place for the IR sensor.
1
2
3
4
5
Beta 1760_IR1600.indd 30 14-04-2008 14:03:45
31
EN
BATTERY REPLACEMENT
If battery power is not sufcient, the LCD will display “ ” and replacement of the 9V type
battery is required.
Open the battery cover, then take out the battery
1
2
NOTES:
How it Works. Infrared thermometers measure the surface temperature of an object. The unit’s
optics sense emitted, reected, and transmitted energy, which is collected and focused onto a
detector. The unit’s electronics translate the information into a temperature reading, which is
display on the unit. In units with a laser, the laser is used for aiming purposes only.
Beta 1760_IR1600.indd 31 14-04-2008 14:03:45
32
EN
YES NO
Field of View Make sure that the target is larger than the unit’s spot size. The smaller the target,
the closer you should be to it. When accuracy is critical, make sure the target is at least twice
as large as the spot size.
Distance & Spot Size. As the distance (D) from the object increases, the spot size (S) of the
area measured by the unit becomes larger. See: Fig: 1.
Locating a hot spot. To nd a hot spot aim the thermometer outside the area of interest, then
scan across with an up and down motion until you locate a hot spot.
Beta 1760_IR1600.indd 32 14-04-2008 14:03:46
33
EN
Reminders
The unit is not recommended for use in measuring shiny or polished metal surfaces (stainless
steel, aluminum, etc.).See Emissivity.
The unit cannot measure through transparent surfaces such as glass. It will measure the surface
temperature of the glass instead.
Steam, dust, smoke, etc., can prevent accurate measurement by obstructing the unit’s optics.
Emissivity
1
2
3
Emissivity is a term used to describe the energy-emitting characteristics of materials.
Most (90% of typical applications) organic materials and painted or oxidized surfaces have an
emissivity of 0.95 (pre-set in the unit). Inaccurate readings will result from measuring shiny or
polished metal surfaces. To compensate, cover the surface to be measured with masking tape or
at black paint. Allow time for the tape to reach the same temperature as the material underneath
it. Measure the temperature of the tape or painted surface.
Beta 1760_IR1600.indd 33 14-04-2008 14:03:46
34
EN
Emissivity Values
Substance Thermal emissivity Substance Thermal emissivity
Asphalt 0.90 to 0.98 Cloth (black) 0.98
Concrete 0.94 Human skin 0.98
Cement 0.96 Lather 0.75 to 0.80
Sand 0.90 Charcoal (powder) 0.96
Earth 0.92 to 0.96 Lacquer 0.80 to 0.95
Water 0.92 to 0.96 Lacquer (matt) 0.97
Ice 0.96 to 0.98 Rubber (black) 0.94
Snow 0.83 Plastic 0.85 to 0.95
Glass 0.90 to 0.95 Timber 0.90
Ceramic 0.90 to 0.94 Paper 0.70 to 0.94
Marble 0.94 Chromium oxides 0.81
Plaster 0.80 to 0.90 Copper oxides 0.78
Mortar 0.89 to 0.91 Iron oxides 0.78 to 0.82
Brick 0.93 to 0.96 Textiles 0.90
Beta 1760_IR1600.indd 34 14-04-2008 14:03:46
35
EN
MAINTENANCE & CLEANING:
Repairs and servicing are not covered in this manual and should only be performed by qualied
personnel.
Periodically wipe the case with a dry cloth. Do not use abrasives or solvents on this instru
-
ment.
When servicing, use only specied replacement parts.
Declaration of conformity (CE)
The product 1760/IR1600 is in conformity with EMC directive 89/336/CEE emanated from the
Commission of the European Community.
Beta 1760_IR1600.indd 35 14-04-2008 14:03:46
102
NL
Uitstralingswaarden
Stof Thermische uitstraling Stof Thermische uitstraling
Asfalt 0.90 tot 0.98
Stof (zwart) 0.98
Beton 0.94 Mensen huid 0.98
Beton 0.96 Schuim 0.75 tot 0.80
Zand 0.90 Houtskool (poeder) 0.96
Aarde 0.92 tot 0.96 Lak 0.80 tot 0.95
Water 0.92 tot 0.96 Lak (mat) 0.97
Ijs 0.96 tot 0.98 Rubber (zwart) 0.94
Sneeuw 0.83 Plastic 0.85 tot 0.95
Glas 0.90 tot 0.95 Hout 0.90
Keramiek 0.90 tot 0.94 Papier 0.70 tot 0.94
Marmer 0.94 Chromium oxiden 0.81
Plaaster 0.90 tot 0.90 Koper oxiden 0.78
Mortel 0.89 tot 0.91 Ijzeroxiden 0.78 tot 0.82
Baksteen 0.93 tot 0.96 Textiele 0.90
Beta 1760_IR1600.indd 102 14-04-2008 14:04:08
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122

Beta 1760/IR1600 Operating instructions

Category
Measuring, testing & control
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI