ZKTeco FR1500S Installation guide

Type
Installation guide

ZKTeco FR1500S is a Silk ID reader that can be connected to a host machine for transferring fingerprint information through RS485. It features a compact design and can be mounted on a standard single gang junction box or inside the wall. The device has a built-in LED indicator for visual feedback during verification or punching. It supports various connection options, including integration with control panels and standalone access controllers. The reader can store and verify fingerprint data and provides real-time verification status through LED signals and audible beeps.

ZKTeco FR1500S is a Silk ID reader that can be connected to a host machine for transferring fingerprint information through RS485. It features a compact design and can be mounted on a standard single gang junction box or inside the wall. The device has a built-in LED indicator for visual feedback during verification or punching. It supports various connection options, including integration with control panels and standalone access controllers. The reader can store and verify fingerprint data and provides real-time verification status through LED signals and audible beeps.

Installation Guide
FR1500S
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency
between the actual product and the written information in this manual.
Installation
1
Dimensions(mm)
Remove both the screws
STEP 1
Procedure to be followed before installation
Note: Not all the devices have the fingerprint cover. The real
product prevails.
77.3
121.3
7.1
38.0
Installation
2
Take out the front panel as shown below
STEP 2
Method 1: Mounting on the standard Single gang junction box
Lay the cables from the desired hole in Single gang junction box and fix the machine part
to the box part.
The Single gang junction box's size
recommendations:
Location column: 83.3mm
Inside of the box Depth: Minimum 36mm
Outside the box size: maximum length
120mm , maximum width 76mm
83.3mm
36mm
120mm
76mm
3
Method 2: Mounting inside the wall
STEP 1 Place the mounting sticker
to the place where device
needs to be installed
STEP 2 Drill fixing holes and dig mounting
groove deep of 36mm
10
11
Instruction for the Mounting Paper
Before the device is fastened, please
stick the paper to the place where you
want to install it, then make holes and
lay cables according to the mounting
paper.
Fixing Hole
Fixing Hole
Moun tin g Pap er
(onl y for y our r efe rence )
The d epth of t he inst allat ion
gro ove is 36 mm
wall
36mm
STEP 3 STEP 4
If cables need to be laid from
behind then it must be done
before installing
Install the device with the screws
After installing the back plate attach the machine part in the
same reverse manner as shown in previous page
STEP 5
Wiring Terminals
This reader is an innovative Silk ID reader. It needs to be connected to a host
machine so that fingerprint information can be transferred through Rs485.
Reader wires nomenclature and Dip Switch
Dip Switch
RED 12V
BLACK GND
YELLOW 485+
PURPLE 485-
BLACK GND
+12V
GND
485-
485+
EXT
-
+
DC12V
1 2 8
Connected as inBIO Pro Reader(with External 485), maximum 8 readers
can be connected. The reader requires a separate power supply.
4
1. Connection with a Control Panel.
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
so on. ... ..
DC12V
-
+
-
+
> Dip Switch setting with control panel
Terminal
Resistance
8
4
2
1
1 2 3456
Swi tch Set ting Swi tch Set ting
Addr ess A ddre ss
1
2
3
4
5
6
7
8
1 2 34561 2 3456
1 2 34561 2 3456
1 2 3456
1 2 3456
1 2 3456
1 2 3456
5
Working Principle
Number 1, 2, 3, 4 of the dip switch are used to set the address of RS485, 5 is the
restart switch, and 6 is the Terminal Resistance.
Number 5 is the restart switch: dial up and dial down. The machine will restart.
The right side figure shows the address number setting.
Number 6 switch is used to set the terminal resistance in RS485.
Communication: If the 485 communication wire is longer, than 100 meters, it is
needed to set the number 6 dip switch of the last reader to ON state, that is
parallel a terminal resistance of 120 ohm between 485+ and 485-.
+12V
GND
GND
485+
485-
2. Connection with a Standalone Access Controller
6
+12V
GND
485A
GND
485B
1
4
+12V
GND
1
5
GND
485A
485B
When using the reader with Standalone access controller device, please move
the dial code “1” to the ON position as shown above.
Verification Proccess
7
Safety Precautions
1. Power cable should be connected at last, after all the wiring. If the device is
working abnormally, immediately shutdown the device.
2. Please read the terminals description and wiring by rule strictly. Any damage
caused by improper operations will be out of the range of our guarantee.
3. Please connect the ‘GND’ before all the other wiring especially under the
serious electrostatic environment.
4. Keep the exposed part of wire less than 5mm to avoid unexpected connection,
and result in machinery damage.
5. If the distance between power supply and device is little long, please do not
use the Internet cable or other types of cable instead. When choosing the
power supply cable, you should consider that the transmission distance may
cause voltage attenuation.
Connection with the controller:
Unsuccessful: LED flashes blue light twice every one second.
Successfully: LED flashes blue light once every one second.
When verifying the fingerprint or punching the card:
Successful Verification:
Authentication error:
Data Error:
Timeout:
Authentication failed: Red LED, two short BEEP
No rights: Red LED, three short BEEP
Verify unfinished: Red LED flashes three times
Green LED lights, short BEEP
Red LED lights, two short and a long BEEP
Red LED lights, one short and a long BEEP
Red LED lights, four short BEEP
Copyright © 2020 ZKTECO CO., LTD. All Rights Reserved.
Tangxia Town, Dongguan, China.
No. 26, 188 Industrial Road,
Phone : +86 769 - 82109991
Fax : +86 755 - 89602394
www.zkteco.com
FCC warning:
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

ZKTeco FR1500S Installation guide

Type
Installation guide

ZKTeco FR1500S is a Silk ID reader that can be connected to a host machine for transferring fingerprint information through RS485. It features a compact design and can be mounted on a standard single gang junction box or inside the wall. The device has a built-in LED indicator for visual feedback during verification or punching. It supports various connection options, including integration with control panels and standalone access controllers. The reader can store and verify fingerprint data and provides real-time verification status through LED signals and audible beeps.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI