Aiphone GT Quikstart Guide

Type
Quikstart Guide

Aiphone GT is a multi-tenant entry security system that provides secure and convenient access control for residential and commercial buildings. It features audio and video entry stations, tenant stations, security guard/concierge stations, and various accessories to create a customized entry solution. The system supports loop wiring and homerun wiring methods, allowing for flexible installation options. With its expandable design, the Aiphone GT system can accommodate up to 125 tenants and 8 entrance stations, making it suitable for small to medium-sized buildings.

Aiphone GT is a multi-tenant entry security system that provides secure and convenient access control for residential and commercial buildings. It features audio and video entry stations, tenant stations, security guard/concierge stations, and various accessories to create a customized entry solution. The system supports loop wiring and homerun wiring methods, allowing for flexible installation options. With its expandable design, the Aiphone GT system can accommodate up to 125 tenants and 8 entrance stations, making it suitable for small to medium-sized buildings.

QuikStart Installation Guide
This is an abbreviated Installation Manual, addressing wiring and programming of the GT Series. The
complete GT Series Installation Manual is located on the CD supplied with the GT-BC Bus Control
Unit. Access the PDF le from the CD and print the entire manual if a hard copy is needed. If installing a digital
entry system, the program for loading names and numbers for each tenant is also located on the CD.
ATTENTION:
GT SERIES
Multi-Tenant Entry Security
How-To
Video Link
Installation Videos
*DP
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-1A
4-15/16" 1-1/4"
6-7/8"
CN2
CN2
CN2
CN1
CN1
CN1
PS-2420UL
GT-BCGT-VBC
PS-2420UL PS-2420UL
1P
1P1P
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P
1P x 2
1P x 2
1P x 2
1P x 2
GT-4Z
GT-4Z
Doorbell
1P
GFK-PS
GT-1C
GT-1C
1P x 2
1P x 2
Trunk Line No. 1
Homerun using
GT-4Z (max. 6)
Trunk Line No. 2
Loop wiring
(max. 25)
Trunk Line
No. 3-6
GT-MK w/
GFW-S
GT-MK w/
GFW-S
Security Guard/Concierge Stations (max. 2)Entrance Stations (max. 5)
NOTE: Do not mix loop and
homerun wiring methods
on the same trunk.
GT Standard Configuration Sample
R1
R2
+
-
+
-
R1 R2R1 R2
GTA-DES
5-5/16"
12-5/8"
1-3/4"
1/2"
CN2
CN1
CN3
CN100
+
-
+
-
ELC
ELM
ELB
PT
Mag
Lock
ELC
ELM
ELB
PT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
PS24
PS24
GT-BC
Loop Wiring Method
Max. of 25 stations per loop / trunk
Homerun Wiring Method
*Distribution Point:
NOT provided by
Aiphone. This can be
any device that parallels
or commons the R1 / R2
connection. (Terminal
strip, punch down block,
wire nuts, etc.)
Tenant stations shown are
the GT-1A. The GT-1D
tenant stations can also
be used and wire in the
same manner.
2 | GT Series QuikStart Guide
Door
Strike
SYSTEM WIRING: AUDIO ONLY DIRECT SELECT & DIGITAL DISPLAY ENTRANCE STATIONS
R1
R1
R2
R2
Max. wire distance from distribution point to any tenant is 980’.
Max. cumulative wire distance is 8200’.
Refer to page 9 of the GT Series Installation Manual for complete wire distance information.
WIRE TYPE
872002
20AWG 2 Cond.
Solid Non Shielded
PE Insulated
871802
18AWG 2 Cond.
Solid Non Shielded
PE Insulated
POWER
PS24
PS-2420UL
PT
Power Transformer
(Use proper power
for the Strike or Mag
Lock being used).
*DP
16-1/8"
2-11/16"
5-7/8"
GT-DM
CN2
CN1
CN3
CN100
CN3
CN1
16-3/4"
5-5/16"
1-3/4"
1/2"
GTV-DES104
ELC
ELM
ELB
PT
R1
R2
+
-
+
-
PS24
+
-
ELC
ELM
ELB
PT
A1 A2R1 R2
A1
A2
PS-2420UL
GT-BCGT-VBC
PS-2420UL PS-2420UL
1P
1P1P
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P x 2
1P
1P x 2
1P x 2
1P x 2
1P x 2
GT-4Z
GT-4Z
Doorbell
1P
GFK-PS
GT-1C
GT-1C
1P x 2
1P x 2
Trunk Line No. 1
Homerun using
GT-4Z (max. 6)
Trunk Line No. 2
Loop wiring
(max. 25)
Trunk Line
No. 3-6
GT-MK w/
GFW-S
GT-MK w/
GFW-S
Security Guard/Concierge Stations (max. 2)Entrance Stations (max. 5)
NOTE: Do not mix loop and
homerun wiring methods
on the same trunk.
GT Standard Configuration Sample
R1
R2
+
-
+
-
PS24
GT-BC
+
-
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
B1 B2 R1 R2
B1 B2 R1 R2
B1 B2 R1 R2
B1 B2 R1 R2
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
B1 B2 R1 R2
B1 B2 R1 R2
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
B1 B2 R1 R2
B1 B2 R1 R2
Max. of 25 stations
per loop. SW1 switch
must be set to A on last
monitor in the wire loop.
SW1
A B
SW1
A B
SW1
A B
SW1
A B
B1 B2 R1 R2
B1 B2 R1 R2
B1 B2 R1 R2
B1 B2 R1 R2
B1 B2 R1 R2
B1 B2 R1 R2B1 B2 R1 R2
B1 B2 R1 R2
SW1
A B
SW1
A B
SW1
A B
SW1
A B
SW1
A B
SW1
A B
SW1
A B
SW1
A B
Max. of 6 GT-4Zs per loop. SW1 switch must be
set to A on last GT-4Z in the wire loop. Each tenant
station homeruns to a GT-4Z and its SW1 switch
must be set to A.
GT-VBC
B1 B2 R1 R2 B1 B2 R1 R2
B1 B2 R1 R2 B1 B2 R1 R2 B1 B2 R1 R2
R1 R2B1 B2
OUT (1) OUT (2)
OUT (3) OUT (4)
IN
LINE OUT
SW1
A
B
GT-4Z
B1 B2 R1 R2 B1 B2
R1 R2
B1 B2 R1 R2 B1 B2 R1 R2 B1 B2 R1 R2
R1 R2B1 B2
OUT (1) OUT (2)
OUT (3) OUT (4)
IN
LINE OUT
SW1
A
B
GT-4Z
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
IN
IN
IN
IN
IN
IN
IN
Loop Wiring Method Homerun Wiring Method
3
*Distribution Point:
NOT provided by
Aiphone. This can be
any device that parallels
or commons the R1 / R2
connection. (Terminal
strip, punch down block,
wire nuts, etc.)
Tenant stations shown
are the GT-1C. The
GT-2C or GT-1M-L
tenant stations can also
be used and wire in the
same manner.
Note: GT-2C requires
a separate PS-2420UL
power supply.
Mag
Lock
Door
Strike
SYSTEM WIRING: AUDIO / VIDEO ALL-IN-ONE & DIGITAL ENTRANCE STATIONS
R1
R1
R2
R2
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
4 | GT Series QuikStart Guide
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
B1
B2
B1
B2
B1
B2
B1
B2
COMMON 1
SUB 1
SUB 2
A1
A2
A1
A2
~
COMMON 2
CN2
+
-
COMMON 1
R1
R2
R1
R2
~
COMMON 2
CN1
R1
R2
R1
R2
~
R1
R2
SUB 1A
R1
R2
R1
R2
~
SUB 1B
R1
R2
R1
R2
~
SUB 2A
R1
R2
R1
R2
~
SUB 2B
R1
R2
R1
R2
~
GTW-LC
USB
GT-VBX
GT-BCX
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
*DP
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
#1 #5#3 #7#2 #6#4 #8
R1
R2
R1
R2
+
-
IN
OUT
GT-MK
R1
R2
R1
R2
+
-
IN
OUT
GT-MK
+
-
PS24
ON
1 2 3
4
#2
ON
1 2 3
4
#1
+
-
PS24
Connection
for video
entrance
modules 9-16
{
{
Connection
for audio
entrance
modules 9-16
R1
R2
+
-
GT-BC
+
-
PS24
+
-
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
B1
B2
B1
B2
B1
B2
B1
B2
B1
B2
B1
B2
+
-
EXP STD
+
-
R1
R2
*DP
PS24
GT-BC
Video outputs to
tenant stations
and / or GT-4Z
units. Max. of
25 tenants per
trunk and 125
total tenants per
GT-VBC.
Audio output to
tenant stations
and / or GT-4Z
units. Max. of
25 tenants per
trunk and 125
total tenants
per GT-BC.
GT-VAGT-DA
SYSTEM WIRING: EXPANDED SYSTEM
OPTION CONNECTOR: TENANT STATIONS
GT-VBC
K
KE
RY
RY
SW
SW
S1
S1E
S2
S2E
S3
S3E
V+
V
-
Emergency alarm
(Brown)
(Brown)
(Red)
(Red)
Ext. Signaling (GT-RY)
(Blue)
(Orange)
(White)
(Yellow)
Video out
Display transfer
Option contact output
(Gray)
(Black)
Secur
ity/Utility input 1
(Orange)
(Black)
Secur
ity/Utility input 2
(Yellow)
(Black)
Secur
ity/Utility input 3
(Purple)
(Black)
12-pin option connector
4-pin option connector
(not included)
DC
DC
RY
RY
SW
SW
Doctor
call (Automatic entry)
(Yellow)
(Orange)
External Signaling (GT-RY)
(Blue)
(White)
Option contact output
(Gray)
(Black)
Option connector
DC
DC
RY
RY
SW
SW
Doctor call (Automatic entry)
(Yellow)
(Orange)
External Signaling (GT-RY)
(Blue)
(White)
Option contact output
(Gray)
(Black)
Option connector
GT-1A
4-15/16" 1-1/4"
6-7/8"
GT-2C
GT-1A
GT-1C
Only the option connectors for the GT-2C, GT-1C, and GT-1A
are shown here. For information on other tenant station option
connectors and for technical specications for each connection,
refer to pages 30-31 of the GT Series Installation Manual.
*
Distribution Point:
NOT provided by Aiphone.
This can be any device
that parallels or commons
the R1 / R2 connection.
(Terminal strip, punch down
block, wire nuts, etc.)
K
KE
RY
RY
SW
SW
S1
S1E
S2
S2E
S3
S3E
V+
V
-
Emergency alarm
(Brown)
(Brown)
(Red)
(Red)
Ext. Signaling (GT-RY)
(Blue)
(Orange)
(White)
(Yellow)
Video out
Display
transfer
Option contact output
(Gray)
(Black)
Security/Utility input 1
(Orange)
(Black)
Security/Utility input 2
(Yellow)
(Black)
Security/Utility input 3
(Purple)
(Black)
12-pin option connector
4-pin option connector
(not included)
GT-1C, GT-1CB, GT-1CS
5-1/2"
7-1/2"
1-3/16"
5
DIP SWITCH SETTINGS: ENTRANCE STATION (REQUIRED)
DIP SWITCH SETTINGS: ENTRANCE STATION (OPTIONAL)
Entrance ID Setting:
Use SW2 on the GT-DA-L module or SW1 on the GT-DM entrance station to set the ID settings for each entry panel.
Only switches 2, 3, & 4 are used for this setting.
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
#1 #5#3 #7#2 #6#4 #8
Guidance Language Setting:
The guidance is set to off (No Guidance) when shipped. Use SW3 on the GT-DA-L module to set the appropriate
language. Only switches 2, 3, & 4 are used for this setting.
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
No Guidance English German DutchFrench Spanish Italian
Message Setting:
Use switch 3 of SW1 on the GT-NS module to select between greeting message or operation message on the display.
Default is “Greeting Message.”
Room Number Display:
Use switch 2 of SW1 on the GT-NS module to choose between displaying only resident name or displaying resident
name and number. Default is “Display resident name and number.”
GT-DA-L
16-1/8"
2-11/16"
5-7/8"
GT-DM
GT-DA-L
GT-DM
GT-NS
GT-NS
3
2
Operation Message
Display only resident name
Greeting Message
Display resident name and number
NOTE:
When using the GT-DM, the settings listed below will be done via the keypad / display while in programming mode.
Refer to the GT Series Installation Manual (pages 43 - 49) for set-up instructions.
ON
1 2 3
4
Entrance Monitoring:
Use switch 1 of SW2 on the GT-DA-L module to enable / disable entrance monitoring. Default is “Monitoring not
possible.” Enabling will allow tenants (video tenants only) to ‘call up’ the entrance station and monitor the door area.
1
Monitoring possible
Monitoring not possible
GT-DA-L
Camera View:
Use switches 3 & 4 of SW1 on the GT-VA module to set the camera view. The default setting is Zoom.
Zoom 3s>>Wide: Image starts zoomed and after 3 seconds goes wide.
Wide 3s>>Zoom: Image starts wide and after 3 seconds zooms.
GT-VA
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ON
1 2 3
4
ZOOM WIDE ZOOM 3s>>WIDE WIDE 3s>>ZOOM
(default)
(default)
6 | GT Series QuikStart Guide
PROGRAMMING: INPUT RESIDENT INFORMATION
NOTE:
The GT digital panel, GT-DM, and GT-MK must be programmed with the resident information before tenant stations can
be addressed. The resident information can be entered using the keypad or by using the software supplied on the CD.
Direct Select / Push Button Entrance Station Addressing
Step 1: Remove front cover from entrance station.
Step 2: To enter programming mode, use a small screwdriver to push and release button under the
rubber cap on front of speaker module (GT-DA-L). The amber LED will begin ashing, then
remain lit. Once lit, the entry panel is in programming mode.
Step 3: At tenant station, push and release the TALK button or pick up the handset to establish
communication with the entrance station in programming mode.
Step 4: Push and release the desired Call Button on the entrance station to assign the button to the
tenant station that is active. A blip tone will be heard.
Step 5: Turn off or hang up tenant station (GT-1A: Push TALK again, GT-1C / GT-2C: Push OFF).
Step 6: Repeat steps 3-5 for remaining tenant stations.
Step 7: To exit programming, push the button under the rubber cap on the GT-DA-L module again
and the amber LED will turn off. The system is now ready for use.
PROGRAMMING: ADDRESSING TENANTS VIA HAND-SHAKE METHOD
Entering Resident Info Using Keypad
Step 1: On the keypad, enter # plus the ID code (
*
1111). Re-enter ID code.
Step 2: Scroll to
RESIDENT INFO.
and press Bell button .
Step 3:
ROOM # will display on the screen. Enter the desired room number (ie: 101, 102, 103, etc.) and press Bell button .
Step 4: The room number entered will appear on screen along with a space for the Resident Name. Use the
Keypad and Arrow buttons to key in the resident name (if desired) and press Bell button when nished.
Step 5: Repeat steps 3 & 4 for remaining residents.
Step 6: Press “X” to return to main menu. Scroll to
QUIT
and press “X” again to exit programming.
Entering Resident Info Using Software
Step 1: Using the CD supplied with the GT-BC, install the GT software and USB cable driver on a PC running
Windows
®
XP, Windows Vista
®
, or Windows
®
7.
Step 2: Open GT software, click
GT System Mode
.
Step 3: Select
Resident
tab.
Step 4: Enter a Room # and Name (if desired) for each resident.
Step 5: Connect the USB cable to the PC and to the GT device being programmed. Ensure that the GT device
being programmed is powered.
Step 6: Refer to the PC’s device manager to determine which COM Port is being used for the cable driver.
Step 7: Select
Connection
COM Port
from the menu bar to see the available COM Ports on the PC.
Select the COM Port that was veried in Step 6.
Step 8: Select
Connection
Export
from the menu bar.
(Export sends data to the entrance station. Import pulls data from the entrance station.)
Step 9: A new window will open asking, “Do you want to overwrite the information?” Select
Yes
.
Step 10: Enter ID code (default is
*
1111) and click
OK
.
Data will be transferred.
Do not press and hold the Call Button as doing so will clear the memory for this button.
How-To
Video Link
How-To
Video Link
7
PROGRAMMING: ADDRESSING TENANTS VIA HAND-SHAKE METHOD (continued)
GT-DM Entrance Station Addressing
Step 1: While in standby mode, enter # plus ID code (default is
*
1111). Re-enter ID code.
Step 2: Use the up / down arrows and scroll to
PROGRAMMING
. Push the Bell button to enter
programming mode. The amber LED will begin ashing, then remain lit. Once lit, the entry panel is
in programming mode. The LCD will show “CONNECTING” while in programming mode.
Step 3: At tenant station, push and release the TALK button or pick up the handset to establish
communication with the entrance station in programming mode.
Step 4: Scroll to the station number to be programmed or manually dial the number. When the tenant
station number is displayed, push and release the Bell button
to assign the address to the
tenant station that is active. A blip tone will be heard.
Step 5: Turn off or hang up tenant station (GT-1A: Press TALK again, GT-1C / GT-2C: Press OFF).
Step 6: Repeat steps 3-5 for the remaining tenant stations.
Step 7: To exit programming, press the “X” button on the panel to return to the main menu (the amber LED
will turn off). Scroll to
QUIT
and press the “X” button again. The system is now ready for use.
GT-MK Concierge Station Addressing
Step 1: While in standby mode, enter # plus ID code (default is
*
1111). Re-enter ID code.
Step 2: Use the up / down arrows and scroll to
PROGRAMMING
. Press the Bell button to enter
programming mode. The LCD will show “CONNECTING” while in programming mode.
Step 3: Pick up the handset on the GT-MK and leave off hook.
Step 4: At tenant station, push and release the TALK button or pick up the handset to establish
communication with the GT-MK in programming mode.
Step 5: Scroll to the station number to be programmed or manually dial the number. When the tenant
station number is displayed, push and release the Bell button to assign the address to the
tenant station that is active. A blip tone will be heard from the GT-MK handset.
Step 6: Turn off or hang up tenant station (GT-1A: Press TALK again, GT-1C / GT-2C: Press OFF).
Step 7: Repeat steps 4-6 for the remaining tenant stations.
Step 8: To exit programming, press the “X” button on the GT-MK to return to the main menu. Scroll to
QUIT
and press the “X” button again. The system is now ready for use.
GT Digital Display Entrance Station Addressing
Step 1: Remove front cover from entrance station.
Step 2: To enter programming, use a small screwdriver to push and release button under the rubber cap
on front of speaker module (GT-DA-L). The amber LED will begin ashing, then remain lit. Once
lit, the entrance station is in programming mode. The LCD will show “CONNECTING” while in
programming mode.
Step 3: At tenant station, push and release the TALK button or pick up the handset to establish
communication with the entrance station in programming mode.
Step 4: Scroll to the station number to be programmed or manually dial the number. When the tenant
station number is displayed, push and release the Bell button to assign the address to the
tenant station that is active. A blip tone will be heard.
Step 5: Turn off or hang up tenant station (GT-1A: Press TALK again, GT-1C / GT-2C: Press OFF).
Step 6: Repeat steps 3-5 for remaining tenant stations.
Step 7: To exit programming, push the button under the rubber cap on the GT-DA-L module again and the
amber LED will turn off. The system is now ready for use.
Transferring Data Between Entrance Stations
The tenant / entrance station hand-shake information can be transferred between entrance stations and / or concierge
stations. The above hand-shake procedure must be done at one entrance station before the transfer can occur.
Refer to page 40 of the GT Series Installation Manual for this procedure.
16-1/8"
2-11/16"
5-7/8"
GT-DM
16-3/4"
5-5/16"
1-3/4"
1/2"
GTV-DES104
Do not press and hold the Bell button as doing so will clear the memory for this address.
Do not press and hold the Bell button as doing so will clear the memory for this address.
Never do a transfer from an entrance station or concierge station that has not been addressed with tenant stations.
Do not press and hold the Bell button as doing so will clear the memory for this address.
1214
8| GT Series QuikStart Guide
Decimal
Room ID # Setting:
Use S# for standard
system stations 1-48.
Use A# for expanded
system stations 1-250.
Use B# for expanded
system stations 251-500.
For tenant stations 251-500,
the dip switch assignment is
the same as 1-250.
Tenant stations 1-250 wire
to Sub 1A and Sub 1B of the
GT-BCX while tenants 251-500
wire to Sub 2A and Sub 2B
(see page 4).
Note: 8 binary digits allows
for 255 unique numbers. Only
numbers 1-250 are used by the
GT system.
PROGRAMMING: ADDRESSING TENANTS VIA DIP SWITCH METHOD
Step 1: Set dip switches for all GT-1C and GT-2C stations using the chart
example to the right.
(The full GT Dip Switch Setting Worksheet can be found on the CD included with the GT-BC.)
Step 2: Apply power to system.
Step 3: Install the GT software and USB cable driver on a computer running
Windows
®
XP, Windows Vista
®
, or Windows
®
7.
(Refer to page 6 for COM Port selection steps.)
Step 4: Open the GT software, select [GT System Mode].
Step 5: Select the
Resident
tab.
Step 6: Enter a Room # and Name for each tenant to be programmed.
Step 7:
Select
View
Room ID # Setting
from the menu bar (see Figure 1).
Figure 1
Figure 2
Binary
Figure 3
Dip Switch
1 52 63 7
4 8
1 52 63 7
4 8
1 52 63 7
4 8
1 52 63 7
4 8
1 52 63 7
4 8
1 52 63 7
4 8
1 52 63 7
4 8
1 52 63 7
4 8
ID #
S4
S8
S2
S6
S1 A1
A5
A3
A7
A2
A6
A4
A8
B251
B255
B253
B257
B252
B256
B254
B258
S5
S3
S7
Figure 4 Figure 5
Step 9: Select
Connection
Export
from the menu bar (see Figure 3).
(Export sends data to the entrance station. Import pulls data from the entrance station.)
Step 8: For each Binary Dip Switch setting made in Step 1, enter the appropriate
ID into the Room ID # Setting eld. Ensure that the correct correlation is
kept between tenant name and actual unit (see Figure 2).
Step 10: Check the LinkData box and select
Yes
(see Figure 4).
Step 11: Enter ID code (default is
*
1111) and click
OK
(see Figure 5).
Data will be transferred.
Std
Exp
(Sub 1)
Exp
(Sub 2)
Aiphone Corporation
1700 130th Ave. NE Bellevue, WA 98005
Ph: (800) 692-0200 Fax: (425) 455-0071
www.aiphone.com [email protected]
Visit our website for complete
information and literature on the
GT Series Multi-Tenant Entry
Security System.
www.aiphone.com/home
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Aiphone GT Quikstart Guide

Type
Quikstart Guide

Aiphone GT is a multi-tenant entry security system that provides secure and convenient access control for residential and commercial buildings. It features audio and video entry stations, tenant stations, security guard/concierge stations, and various accessories to create a customized entry solution. The system supports loop wiring and homerun wiring methods, allowing for flexible installation options. With its expandable design, the Aiphone GT system can accommodate up to 125 tenants and 8 entrance stations, making it suitable for small to medium-sized buildings.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI