Watts HydroGuard e700 Installation guide

Category
Sanitary ware
Type
Installation guide

Watts HydroGuard e700 is a thermostatic mixing valve designed to regulate the temperature of water in showers and bathtubs. Here is a summary of some of its capabilities:

  • Temperature control: The HydroGuard e700 allows you to set a maximum temperature for the water, preventing it from getting too hot and causing scalding.
  • Wide range of applications: The HydroGuard e700 can be used in both residential and commercial applications, including showers, bathtubs, and sinks.
  • Easy installation: The HydroGuard e700 comes with a rough-in guide to help ensure proper installation.
  • Durability: The HydroGuard e700 is made from high-quality materials and is built to last.

Watts HydroGuard e700 is a thermostatic mixing valve designed to regulate the temperature of water in showers and bathtubs. Here is a summary of some of its capabilities:

  • Temperature control: The HydroGuard e700 allows you to set a maximum temperature for the water, preventing it from getting too hot and causing scalding.
  • Wide range of applications: The HydroGuard e700 can be used in both residential and commercial applications, including showers, bathtubs, and sinks.
  • Easy installation: The HydroGuard e700 comes with a rough-in guide to help ensure proper installation.
  • Durability: The HydroGuard e700 is made from high-quality materials and is built to last.
INSTALLATION INSTRUCTIONS
NOTICE
Installation should be in accordance with
accepted plumbing practices. Flush all piping thoroughly
before installation.
To Install n
1. Position mixer 1-15/16 ± 1/2 [49mm ± 13mm] from
inlet center to finished wall surface. The tub outlet port
is marked “TUB” and should face down. Facing front of
mixer, connect hot water to left side and connect cold
water to right side. The valve has “C” and “H” cast into the
body near the appropriate inlet ports.
2. Valve is factory-set for standard inlets. If reversed inlets
are required due to back-to-back installation (Cold water
supply on the left and Hot water supply on the right), follow
instructions ad below:
a. Connect cold inlet to hot port (“H”) and hot inlet to
cold port (“C”).
NOTICE
Do not turn valve upside
down. If valve is upside down, water will not flow prop-
erly through tub spout or showerhead.
b. Turn water off with checkstops, remove bonnet and
cartridge.
c. Reinstall cartridge. “H” on the cold side of the valve
body and “C” should be on the hot side of the valve
body.
d. Reinstall bonnet with high temperature limit stop.
NOTICE
Be certain that valve opens in full cold!
e. Hot and Cold inlets should be re-identified for reversed
inlets to avoid confusion during future maintenance.
3. For tub and shower installations, see Figure 1. Pipe bot-
tom outlet port “TUB” directly to the diverter tub spout.
The mixer body is designed to operate without the use of a
twin ell. Pipe top outlet port “S” to the showerhead.
4. For shower only installation, see Figure 2. Pipe top outlet
port “S” directly to the showerhead and plug bottom port.
5. Rough-in guide installation…
a. When piping installation is completed and before doing
the finished wall, slide rough-in guide onto the mixer
stem and press fit into place. (See Figure 4.)
b. The rough-in guide will insure the proper size opening
for mixer and checkstop shut-off and repair accessibil-
ity, as well as protect the chrome-plated sleeve from
damage during drywall and tile installation.
6. To install dial gaskets, peel backing off gaskets and attach
gaskets to inside of dial plate.
6. ( a) For e707
Attach indicator plate gasket to the back of the trim plate
making sure horizontal holes on the gasket matches
horizontal holes on the trim plate. Indicator plate locator
hole matches diagonal hole on the trim plate. Peel off
backing of the trim plate gasket and attach to the inside
top edge of the trim plate. Gasket should be approxi-
mately 1/16” beyond the plate edge.
7. (a) For e705 & e710
After wall is completed, remove rough-in guide. Install
O-ring on the bonnet. Slide sleeve on the bonnet and
attach dial assembly and handle to mixer body with the
screws furnished.
7 (b) For e707
CAUTION
!
Indicator plate must be installed before sleeve.
1. Install trim plate.
2. Snap on the indicator plate. Guide on the back of the
plate goes into the locator hole.
3. Install sleeve O-ring on the bonnet. Slide sleeve on the
bonnet.
4. Install handle and tighten the setscrew.
CAUTION
!
When soldering during installation process, do
not heat the valve any higher than the temperature required
to flow solder. Excessive overheating of the valve may cause
damage to the cartridge mechanism. By following this rec-
ommendation, you will be able to solder the valve without
removing either the cartridge or the checkstop internals.
If either brazing or resistance (electric) solder is to be used, all
valve internals must be removed.
8. Maximum temperature setting adjustment (see Figure 5)
must be set on the job to in no case greater than 110°F
[43°C]. The high temperature limit stop is located on the
bonnet.
NOTICE
Rotate handle to the maximum desired outlet temperature.
With an open-end wrench, screw high temperature limit stop
into bonnet until it touches stem’s shoulder. Close valve and
open it to full hot to verify settings.
II-P-e700
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
Local building or plumbing codes may require modifica-
tions to the information provided. You are required to
consult the local building and plumbing codes prior
to installation. If the information provided here is not
consistent with local building or plumbing codes, the
local codes should be followed. This product must be
installed by a licensed contractor in accordance with
local codes and ordinances.
WARNING
!
9
10
Figure 3
HIGH TEMP. STOP
STEM
Figure 5: Max. Temperature Setting
Figure 4: Rough-In Guide
TROUBLESHOOTING
Description Troubleshooting Repair Kit
No.
Cartridge Kit Water leaks at valve stem
and/or bonnet.
• Water leaks at valve shutoff.
Water temperaure changes
during shower.
220 060
Checkstop
Replacement
Kit
Checkstop leaks or will not
shut off completely.
900 050
ITEM# KIT# DESCRIPTION
1 N/A Valve Body
2 220 060 Cartridge Kit
3 900 050 Checkstop Replacement Kit
4 220 054 Sleeve Kit
5 220 051 Metal Trim Plate Kit For e710
6 220 053 ABS Trim Plate Kit For e705
7 220 050 Metal Handle Kit For e710
8 220 052 ABS Handle Kit For e705
9 220 079 Dome Metal Handle Kit For e707
10 220 078 Metal Flat Trim Plate Kit For e707
WARNING: This product contains chemicals known
to the State of California to cause cancer and birth
defects or other reproductive harm.
For more information: www.watts.com/prop65
TUB OUTLET
TO BE PLUGGED.
PLUG BY OTHERS.
5" [127]
A
24" [609]
APPROX.
WALL
1-7/16" [37] MIN.
2-7/16" [62] MAX.
1/2" [13]
1/2" IPS CONNECTIONS
OR
1/2" COPPER SWEAT
CONNECTIONS
1/2-14" NPT
MALE INLET
ALL DOTTED LINE PIPING SUPPLIED BY OTHERS.
78" [1981]
APPROX.
TO FINISHED
FLOOR
4-5/8" [118] DIA
ROUGH-IN
GUIDE
NOTE:
'T' TO BE
ON BOTTOM
AS SHOWN
3-1/4" [82]
Figure 2: Rough-in Dimensions —
Shower only
Model # “A”
e705 6.5” 165mm
e707 8.5” 216mm
e710 6.5” 165mm
Figure 1: Rough-in Dimensions —
Tub and Shower
Model # “A”
e705 6.5” 165mm
e707 8.5” 216mm
e710 6.5” 165mm
Dimensions in inches [millimeters]
II-P-e700 1515 EDP# 6512215 © 2015 Powers
USA: Tel: (800) 669-5430 • Fax: (847) 229-0526 • PowersControls.com
Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • PowersControls.ca
Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • PowersControls.com
A Watts Water Technologies Company
  • Page 1 1
  • Page 2 2

Watts HydroGuard e700 Installation guide

Category
Sanitary ware
Type
Installation guide

Watts HydroGuard e700 is a thermostatic mixing valve designed to regulate the temperature of water in showers and bathtubs. Here is a summary of some of its capabilities:

  • Temperature control: The HydroGuard e700 allows you to set a maximum temperature for the water, preventing it from getting too hot and causing scalding.
  • Wide range of applications: The HydroGuard e700 can be used in both residential and commercial applications, including showers, bathtubs, and sinks.
  • Easy installation: The HydroGuard e700 comes with a rough-in guide to help ensure proper installation.
  • Durability: The HydroGuard e700 is made from high-quality materials and is built to last.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI