5
C. If you have a multi stage HVAC system comprised of a fossil
fuel heater with air conditioning the Venstar EXPLORER Mini will
requirethe5wiresmentionedabove(R,C,W,Y,andG)plusan
additionalwireforeachadditionalstageofHeatingorCooling.You
may reduce the 5 wire requirement to 4 if you give up independent
fancontrol,orusetheoptionalaccessory;Add-A-Wire.
D. Ifyouhaveaheat pump without aux heat the Venstar EXPLORER
willrequire5wires:R(24Vac),C(24Vac),W1/O/B(reversingvalve),Y
(1ststagecompressor),andG(fan).Ifthereareonly4wirespresent
thatareconnectedtotheexistingthermostat,thereareatleast3
options available to connect the Venstar EXPLORER thermostat,
they are:
1. Usethe4wiresasinstructedbelowandnotethatthefanwill
onlyoperatewithaHeatingorCoolingdemand.
2. PullnewthermostatwirefromtheHVACequipmenttothe
thermostat so that there are at least 5 wires available.
3. PurchaseandinstallaVenstarAdd-A-Wireaccessory(ACC-0410).
E. If you have a heat pump with aux heat the Venstar EXPLORER Mini
willrequire6wires:R(24Vac),C(24Vac),W1/O/B(reversingvalve),
Y(1ststagecompressor),W2(AuxHeat)andG(fan).Ifthereare
only5wirespresentthatareconnectedtotheexistingthermostat,
there are at least 3 options available to connect the Venstar
EXPLORER thermostat, they are:
1. Usethe5wiresasinstructedbelowandnotethatthefanwill
onlyoperatewithaHeatingorCoolingdemand.
2. PullnewthermostatwirefromtheHVACequipmenttothe
thermostat so that there are at least 6 wires available.
3. PurchaseandinstallaVenstarAdd-A-Wireaccessory(ACC-0410).