IQ PANEL BATTERY REPLACEMENT
Remove retaining screw and back plate from the
panel, then unplug the battery.
Remove the battery retaining clip and screw.
Use a finger or thumb and pull up firmly on the
battery to remove.
Do NOT use a screwdriver or anything sharp that could
puncture the battery.
Do NOT pull on the battery cable to try and remove battery.
Place new battery into the battery slot (bottom
first) pushing down into place. To ensure easier
battery replacement in the future, do NOT use
adhesive tape. Screw down retaining bracket, plug
in battery and replace panel back plate.
STEP 1: DISCONNECT BATTERY STEP 2: REMOVE RETAINING CLIP
STEP 3: REMOVE OLD BATTERY STEP 4: INSTALL NEW BATTERY
Replacing the IQ Panel’s standard Li-Ion battery is easy. Please
follow the steps outlined below. Note: you should only attempt this
with factory authorized battery part number QR0018-840
FOR TECHNICAL SUPPORT OR QUESTIONS PLEASE CALL (855) 4-QOLSYS
IMPORTANT!
BEFORE YOU
BEGIN:
To avoid damage or voiding your warranty, you
must properly power down the IQ Panel before
you begin the steps below. See installation
manual for additional details if needed.
Settings Power Down
WAIT UNTIL
LED LIGHTS
ARE OFF