Aiphone NH-2SA-AC User manual

Type
User manual

This manual is also suitable for

Aiphone NH-2SA-AC is a patient station for nurse call systems that allows for all call and sharing a common corridor lamp. This model is compatible with NHX systems and requires an NH-50AC adaptor for all call functionality. The NH-2SA-AC features two call buttons, one for the patient and one for the bathroom, and can be used in conjunction with a corridor lamp (NHR-4A) and a bathroom pullcord (NHR-7A). The device can be wired to annunciate on a specific position at the master station and supports zone lighting if an NHR-3A-4 Zone Light is included in the system.

Aiphone NH-2SA-AC is a patient station for nurse call systems that allows for all call and sharing a common corridor lamp. This model is compatible with NHX systems and requires an NH-50AC adaptor for all call functionality. The NH-2SA-AC features two call buttons, one for the patient and one for the bathroom, and can be used in conjunction with a corridor lamp (NHR-4A) and a bathroom pullcord (NHR-7A). The device can be wired to annunciate on a specific position at the master station and supports zone lighting if an NHR-3A-4 Zone Light is included in the system.

- INSTRUCTIONS -
WIRING DIAGRAM:
NH-1SA-AC NH-2SA-AC
Patient Stations
Single and Dual Patient Stations for All Call,
and when sharing a common Corridor Lamp
NHX-80X
11
12
13
14
15
16
21
22
23
24
25
26
~
51
52
53
54
55
56
A+
A-
B+
B-
NOTES:
1. All Call requires one of the station buttons to be used for All Call.
Therefore, the standard system can have up to 49 stations, and the expanded
system can have up to 79 stations.
2. Only wiring concerning the NH-1SA-AC and NH-2SA-AC is shown here. For
complete installation and wiring information, please see the NHX Installation
instructions.
PS-2420UL
+
-
Trunkage Line
Connection
Terminals
Some applications for Nurse Call systems require All Call. By including the NH-50AC adaptor and the "AC" model
patient stations, a station button on the master can be used to call all of the patient stations simultaneously. An
additional wire is required to each patient station. In addition, if there is more than one patient station sharing a
corridor lamp, this model patient station will allow that configuration to be used.
NOTE:
An NHX system installed with an NH-1SA-AC or NH-2SA-AC included does not carry the UL 1069 listing.
NHX
Nurse Center System
CN1:
Brn
Red
Org
Yel
Grn
Blu
Blk
CN2:
Brn
Red
Org
Yel
Grn
Blu
Vio
Two Patient Stations in one room sharing a bathroom and corridor lamp
NH-1SA-AC
CN1:
Brn
Red
Org
Yel
Grn
Blu
Blk
CN2:
Brn
Red
Org
Yel
Grn
Blu
Vio
NH-2SA-AC
Brn
Red
Org
NHR-4A
Yel
Grn
Blu
Bathroom Pullcord
(Wired to one station only)
PS-2420UL
+
-
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
NH-1/2SA-AC Instr.
0103js
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
APPLICATION #1:
All Call feature added, where an announcement can
be made from the master station to all patient
stations simultaneously.
APPLICATION #2:
2 patient stations in a room with a common
bathroom and one corridor lamp outside the room.
* Bath call will annunciate on
one position at the master
station, according to which
patient station it is wired to.
To NH-50AC
NHR-7A
Corridor Lamp
(Shared by both patient stations)
WIRING:
1. Follow the wiring diagram on front page of these instructions.
2. Connect the corridor lamp wires (Brn, Red, Org) to the same colored wires on CN2 of BOTH
the patient stations in the room. Otherwise, the corridor lamp will not light up when either
patient station places a call.
3. Connect the bathroom station (Yel, Grn, Blu) to the same colored wires on CN2 of JUST ONE
of the patient stations in the room. The bath station for that room will annunciate on the same
position at the master as the station it is wired to.
4. If All Call is not included, do not connect the BLK wire from the patient station.
5. If a Zone Light (NHR-3A-4) is not included in the system, do not connect the VIO wire on CN2.
OPERATION:
1. A call from any of the the handheld call buttons on either station in the room will light on the
master station, and the corridor lamp will light the white lamp steadily.
2. A call from the bath station will light on the master at the station it is wired to, and will flash the
corresponding corridor lamp's red bulb. Bathroom switch must be moved upward to reset the
call.
3. A cord-out call from any station in the room will flash the white bulb. Cord must be reinstalled
in the jack to cancel the call.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX: (425) 455-0071
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
Extensions 8107, 8118, 8111, 8125
TOLL FREE FAX LINE:
(800) 832-3765
NH-1SA,2SA-AC.vsd
0103js
  • Page 1 1
  • Page 2 2

Aiphone NH-2SA-AC User manual

Type
User manual
This manual is also suitable for

Aiphone NH-2SA-AC is a patient station for nurse call systems that allows for all call and sharing a common corridor lamp. This model is compatible with NHX systems and requires an NH-50AC adaptor for all call functionality. The NH-2SA-AC features two call buttons, one for the patient and one for the bathroom, and can be used in conjunction with a corridor lamp (NHR-4A) and a bathroom pullcord (NHR-7A). The device can be wired to annunciate on a specific position at the master station and supports zone lighting if an NHR-3A-4 Zone Light is included in the system.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI