EPH Controls CP4-HW-OT Installation guide

Category
Thermostats
Type
Installation guide
Installation and Operation Guide
Programmable RF Cylinder
Thermostat & Receiver
CP4-HW-OT
13
17
21
RFRP-HW-OT Room Thermostat
5
Installation Instructions
6
Factory Default Settings
6
7
Specications
8
How your cylinder thermostat works
9
10
15
20
RF1A-OT Wireless Receiver
RFRP-HW-OT Room Thermostat
20
Installation Instructions
Operating Instructions
14
19
18
22
Table of contents
Frost Protection
Mounting of temperature sensor
Mounting & Installation
Mounting & Installation
Resetting the thermostat
Keypad lock and unlock
Setting the date, time and programming mode
Specications & Wiring
Button Description
LCD Symbol Description
Factory Program Setting
32
32
31
Installer menu
32
33
23
33
33
24
25
26
27
28
29
Frost Protection
Frost Protection
29
30
PO 3 Hysteresis H ON and H OFF
Normal
PO 1 Operating Mode
Adjust the program setting in 5/2 Day mode
Copy Function
Permanent Override
Boost Function
Holiday Function
Battery low warning
Backlight mode selection
Replacing the batteries
PO 4 Calibrate the thermostat
Programming Modes
PO 5 Frost Protection
Exit
42
RFRP-HW-OT Room Thermostat (Continued)
Installer menu - OpenTherm®
34
36
Controlling an OpenTherm® Boiler with multiple CP4-OT / CP4-HW-OT
35
40
44
46
RF1A-OT Wireless Receiver
Operating Instructions
43
45
Table of contents (Continued)
PO 7 OpenTherm® Information
Exit
System Architecture
LED Description
To disconnect the RFRP-HW-OT thermostat to an RF1A-OT receiver
Button / LED Description
To connect the RFRP-HW-OT thermostat to an RF1A-OT receiver
5
RFRP-HW-OT Cylinder Thermostat
Installation Instructions
6RFRP-HW-OT Room Thermostat CP4-HW-OT
RFRP-OT Room Thermostat
Factory Default Settings
Temperature indicator: ˚C
Switching dierential: 5˚C
In built frost protection: 5˚C - Not adjustable
Clock: 24 hours
Keypad lock: OFF
Operating mode: 5/2 day
Default temperature setpoint: 60˚C
Frost Protection 5˚C
Frost protection is built into this thermostat.
It is pre xed at 5°C and is not adjustable.
It will only be activated when the thermostat is in the OFF mode and the
cylinder temperature falls below 5°C.
7
RFRP-HW-OT Room Thermostat CP4-HW-OT
Specications
Power supply: 2 x AA Alkaline Batteries
Power consumption: 2 mW
Battery replacement: Once a year
Temp. control range: 5 … 90˚C
Ambient temperature: 0 … 45˚C
Dimensions: 130 x 99 x 25mm
Temperature sensor: NTC 100K Ohm @ 25˚C
External sensor length: 1950mm ± 80mm
Temperature indication: ˚C
Switching dierential: 5˚C
Frost protection: Only operational in OFF mode
Pollution degree: Pollution degree 2
8RFRP-HW-OT Room Thermostat CP4-HW-OT
When the thermostat is in the AUTO mode, it will operate according
to the times that have been programmed. The user can select from 6
dierent programs per day - each with a time and a status of ON or OFF.
When program is scheduled to be ON, it will remain on until the next
OFF program.
During this time the thermostat will remain ON until the temperature
setpoint is reached.
There is only one temperature setpoint which is applied to all programs.
The default temperature setpoint is 60˚C.
60˚C is the temperature level required in order to prevent the build up
of legionella bacteria.
How your cylinder thermostat works
9
RFRP-HW-OT Room Thermostat CP4-HW-OT
ON CYLINDER: To ensure accurate control of your cylinder, the
temperature sensor should be mounted on the bottom 1/3 of the
cylinder. It is essential that the sensing element is in direct contact with
the cylinder and that there is no insulation between it and the cylinder.
The temperature sensor can be xed to the cyliner using the provided
foil tape.
ON PIPEWORK: To ensure accurate control, the temperature sensor
should be mounted on the pipework as tightly as possible. It is essential
that the sensing element is in direct contact with the pipework and that
there is no insulation between it and the pipework. The temperature
sensor can be xed to the pipework using foil tape.
IN THERMAL POCKET: To ensure accurate control, the temperature
sensor should be inserted into the thermal pocket. It is essential that
the sensing element is inserted as far as possible. The temperature
sensor can be xed using the provided foil tape.
Mounting of temperature sensor
10 RFRP-HW-OT Room Thermostat CP4-HW-OT
Mounting & Installation
Caution!
Installation and connection should only be carried out by a qualied person.
Only qualied electricians or authorised service sta are permitted to open the
thermostat.
If the thermostat is used in a way not specied by the manufacturer, its safety may be
impaired.
Prior to setting the thermostat, it is necessary to complete all required settings
described in the section.
This thermostat can be mounted directly on the wall using the plate included.
11
RFRP-HW-OT Room Thermostat CP4-HW-OT
1) The mounting height should be 1.5 metres above the oor level.
2) The place of installation should be chosen so that the sensor can
measure the temperature as accurately as possible.
Choose the mounting location to prevent direct exposure to
sunlight or other heating / cooling sources when mounted.
3) Fix the mounting plate directly to the wall with the screws provided.
4) Attach the thermostat to the mounting plate.
5) Lower the ap at the front of the thermostat. There is a battery
compartment located below the buttons. Apply downward
pressure to remove the cover.
6) Insert the 2 x AA batteries and the thermostat will turn ON.
Close the battery compartment.
Mounting & Installation (Continued)
12
1 2
131
100
φ
5
25
1950±80mm
34
5 6
13
RF1A-OT Wireless Receiver
Installation Instructions
14 RF1A-OT Wireless Receiver CP4-HW-OT
Internal wiring diagram for RF1A-OT
Specications & Wiring
Power supply: 200 - 240Vac 50-60Hz
Contact rating: 250 Vac 10(3)A
Ambient temperature: 0 … 45˚C
Automatic action: Type 1.C.Q
Appliance classes: Class II appliance
Pollution degree: Pollution degree2
IP Rating: IP20
Rated Impulse Voltage: Resistance to voltage surge 2500V
as per EN 60730
OFFON
321LN
L
MAINS SUPPLY
N
COM
O T
O T
* If mains voltage output is required,
terminals L & 2 must be electrically
linked.
Important: Do not connect Mains
Voltage to OpenTherm® terminals.
15
RF1A-OT Wireless Receiver CP4-HW-OT
1) The RF1A-OT receiver should be wall mounted in an area within
20 metres distance of the wireless thermostat. It is important
that the receiver is mounted more than 300mm away from metal
objects as this will aect communication with the thermostat.
The receiver should be installed at least 1 metre from any electronic
devices such as radio, TV, microwave or wireless network adaptor.
2) Slacken the fastening screw on the bottom of the receiver with a
philips screwdriver. The receiver is hinged and can be opened 180
degrees.
3) Screw the receiver to the wall with the screws provided.
4) Remove the protective cover on the terminal block.
5) Insert wires into terminal block in accordance with the wiring
diagram.
6) Close the cover and tighten the fastening screw.
Mounting & Installation
16
1 2
34
5 6
17
RFRP-HW-OT Cylinder Thermostat
Operating Instructions
18 RFRP-HW-OT Room Thermostat CP4-HW-OT
LCD Symbol Description
Operating mode
Current program
Day / Month
Day of the week
Temperature
Battery low symbol
Wireless symbol
Heating on symbol
Keypad lock symbol
Current Time
(Boost to time)
19
RFRP-HW-OT Room Thermostat CP4-HW-OT
Button Description
Automatic mode Set Date / Time Set point increase
Manual mode Holiday mode Set point decrease
O mode Copy function Conrm button
Reset buttonProgram mode Boost mode
AUTO TIME
MAN HOL
OFF COPY OK
PROG BOOST
Manual
mode
O mode
Program mode Set Date/ Time
Holiday mode
Copy function
Boost mode
Automatic
mode
(Back)
OK conrm button
Set point increase
Set point decrease
Reset button
Wireless connect button
20 RFRP-HW-OT Room Thermostat CP4-HW-OT
RFRP-OT Room Thermostat
Resetting the thermostat
Keypad lock and unlock OFF
To lock the keypad, press and hold the and buttons for 10 seconds.
will appear on the screen. The keypad is now locked.
To unlock the keypad, press and hold the and buttons for 10 seconds.
will disappear from the screen. The keypad is now unlocked.
Press the button on the side of the thermostat.
‘rst no will appear on the screen.
Press the button.
‘rst yes’ will appear on the screen.
Press the OK button to reset the thermostat.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

EPH Controls CP4-HW-OT Installation guide

Category
Thermostats
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI