YORKVILLE YX15P User manual

Category
Audio amplifiers
Type
User manual
U.S.A.
Yorkville Sound Inc.
4625 Witmer Industrial Estate
Niagara Falls, New York
14305 USA
Voice: (716) 297-2920
Fax: (716) 297-3689
WORLD HEADQUARTERS
WEB ACCESS: http://www.yorkville.com
CANADA
Yorkville Sound
550 Granite Court
Pickering, Ontario
L1W-3Y8 CANADA
Voice: (905) 837-8481
Fax: (905) 837-8746
Quality and Innovation Since 1963
Printed in Canada
SERVICE MANUAL
YX15P
MODEL TYPE: YS1030
Manual-Service-YX15P-00-1v0.pdf
The exclamation point within an equilatereal
triangle is intended to alert the user to the
presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
Le point d’exclamation à l’intérieur d’un triangle équilatéral
est prévu pour alerter l’utilisateur de la présence
d’instructions importantes dans la littérature accompag-
nant l’appareil en ce qui concerne l’opération et la
maintenance de cet appareil.
This lightning flash with arrowhead symbol,
within an equilateral triangle, is intended to alert
the user to the presence of uninsulated
“dangerous voltage” within the product’s enclosure
that may be of sufficient magnitude to constitute a risk of
electric shock to persons.
Ce symbole d’éclair avec tête de flèche dans un triangle
équilatéral est prévu pour alerter l’utilisateur de la présence
d’un « voltage dangereux » non-isolé à proximité de l’enceinte
du produit qui pourrait être d’ampleur suffisante pour présenter
un risque de choque électrique.
IMPORTANT SAFETY INSTRUCTIONS
safety-4v5.eps • April 3/2007
CAUTION: TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
FOLLOW ALL INSTRUCTIONS SUIVEZ TOUTES LES INSTRUCTIONS
Instructions pertaining to a risk of fire,
electric shock, or injury to a person
Read Instructions: The Owner’s Manual should be read and
understood before operation of your unit. Please, save these instruc-
tions for future reference and heed all warnings.
Clean only with dry cloth.
Packaging: Keep the box and packaging materials, in case the unit
needs to be returned for service.
Warning: To reduce the risk or fire or electric shock, do not expose
this apparatus to rain or moisture. Do not use this apparatus near water!
Warning: When using electric products, basic precautions should
always be followed, including the following:
Power Sources
Your unit should be connected to a power source only of the voltage specified in the
owners manual or as marked on the unit. This unit has a polarized plug. Do not use
with an extension cord or receptacle unless the plug can be fully inserted. Precau-
tions should be taken so that the grounding scheme on the unit is not defeated.
Hazards
Do not place this product on an unstable cart, stand, tripod, bracket or table. The
product may fall, causing serious personal injury and serious damage to the product.
Use only with cart, stand, tripod, bracket, or table recommended by the manufacturer
or sold with the product. Follow the manufacturer’s instructions when installing the
product and use mounting accessories recommended by the manufacturer.
The apparatus should not be exposed to dripping or splashing water; no objects
filled with liquids should be placed on the apparatus.
Terminals marked with the “lightning bolt” are hazardous live; the external wiring
connected to these terminals require installation by an instructed person or the use of
ready made leads or cords.
Ensure that proper ventilation is provided around the appliance. Do not install near
any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
No naked flame sources, such as lighted candles, should be placed on the apparatus.
Power Cord
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug
has two blades with one wider than the other. A grounding type plug has two blades and a
third grounding prong. The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for replacement of the
obsolete outlet. The AC supply cord should be routed so that it is unlikely that it will be
damaged. If the AC supply cord is damaged DO NOT OPERATE THE UNIT.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Service
The unit should be serviced only by qualified service personnel.
AVIS: AFIN DE REDUIRE LES RISQUE DE CHOC
ELECTRIQUE, N’ENLEVEZ PAS LE COUVERT (OU LE
PANNEAU ARRIERE) NE CONTIENT AUCUNE PIECE
REPARABLE PAR L’UTILISATEUR.
CONSULTEZ UN TECHNICIEN QUALIFIE
POUR L’ENTRETIENT
Instructions relatives au risque de feu,
choc électrique, ou blessures aux personnes
Veuillez Lire le Manuel: Il contient des informations qui devraient
êtres comprises avant l’opération de votre appareil. Conservez.
Gardez S.V.P. ces instructions pour consultations ultérieures et
observez tous les avertissements.
Nettoyez seulement avec le tissu sec.
Emballage: Conservez la boite au cas ou l’appareil devait être
retourner pour réparation.
Avertissement: Pour réduire le risque de feu ou la décharge
électrique, n'exposez pas cet appareil à la pluie ou à l'humidité.
N’utilisez pas cet appareil près de l’eau!
Attention: Lors de l’utilisation de produits électrique, assurez-vous
d’adhérer à des précautions de bases incluant celle qui suivent:
Alimentation
L’appareil ne doit être branché qu’à une source d’alimentation correspondant au
voltage spécifié dans le manuel ou tel qu’indiqué sur l’appareil. Cet appareil est
équipé d’une prise d’alimentation polarisée. Ne pas utiliser cet appareil avec un
cordon de raccordement à moins qu’il soit possible d’insérer complètement les trois
lames. Des précautions doivent êtres prises afin d’eviter que le système de mise à la
terre de l’appareil ne soit désengagé.
Risque
Ne pas placer cet appareil sur un chariot, un support, un trépied ou une table instables.
L’appareil pourrait tomber et blesser quelqu’un ou subir des dommages importants.
Utiliser seulement un chariot, un support, un trépied ou une table recommandés par le
fabricant ou vendus avec le produit. Suivre les instructions du fabricant pour installer
l’appareil et utiliser les accessoires recommandés par le fabricant.
Il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que
des bougies allumées.
L’appeil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures
et qu’aucun objet rempli de liquide tel que des vases ne doit être placé sur l’appareil.
Assurez que lappareil est fourni de la propre ventilation. Ne procédez pas à
l’installation près de source de chaleur tels que radiateurs, registre de chaleur, fours
ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.
Les dispositifs marqués d’une symbole “d’éclair” sont des parties dangereuses
au toucher et que les câblages extérieurs connectés à ces dispositifs de
connection extérieure doivent être effectivés par un opérateur forou en utilisant
des cordons déjà préparés.
Cordon d’Alimentation
Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de
mise à la masse du cordon d’alimentation. Une prise polarisée dispose de deux
lames dont une plus large que l’autre. Une prise avec tige de mise à la masse
dispose de deux lames en plus d’une troisième tige qui connecte à la masse. La
lame plus large ou la tige de mise à la masse est prévu pour votre sécurité. La prise
murale est désuète si elle n’est pas conçue pour accepter ce type de prise avec
dispositif de sécurité. Dans ce cas, contactez un électricien pour faire remplacer la
prise murale. Évitez d’endommager le cordon d’alimentation. N’UTILISEZ PAS
L’APPAREIL si le cordon d’alimentation est endommagé.
branchez cet appareil durant les orages ou si inutilisé pendant de longues périodes.
Service
Consultez un technicien qualifié pour l’entretien de votre appareil.
S2125A
1 2 3 4
A
B
C
D
4
3
21
D
C
B
A
20
0F
A
P
RE
T
ite
l
Siz
e
M
o
del N
o
:
Y
X15
P
To CN2 P-200FATONE-BOARD-CIR
Schematic-YX15P-200FAPRE-00-V061113.pdf
A4
R
e
v
ision
V
E
R061
11
3
D
a
t
e:
1
7-
Ma
r-2
00
7 Sh
e
e
t 1
of
1
F
il
e
:
2
0
0FA
P
RE
.
Sc
h
Draw
n
B
y
:
1 2
3
S
3
OUT
1 2
3
S
1
M
IC IN
1 2
3
S
2A
LIN
E IN
6
5
4
S2B
R3
3
3
0
R
R4
330
R
D8
15
V
D
5
1
5
V
D7
1
5
V
D
6
15V
C3
2
2
pF
R6
10R 1/2W
R11
10K
C1
0.01uF/400V
S
S
W S
P
DT
S4
P-250
R3
1
5
V
R4
1
5V
D4
15
V
D
1
1
5
V
D3
1
5
V
D
2
15V
C2
2
2
pF
R5
1
.
2
K
R10
1
.2
K
1
2
3
4
5
6
7
8
9
CN1
2.
5
4 9P
1
2
3
4
C
N
2
2
.
54
4
P
1
2
3
RE
D
G
RN
D
L
1
S
IGN
A
L
/
C
OM
P
D
L
2
P
O
WE
R
T
R2
BC
55
9C
T
R
1
BC
550
C
C4
0.1uF/400V
R1
2
10K
R13
10
K
R
7
1
K
R8
2
.
7
K
R9
2
.
7
K
C
5
1
uF
/5
0
V
-1
5
V
1 2 3
4
A
B
C
D
4
3
2
1
D
C
B
A
P
-200FATONE
Ti
t
e
l
S
i
z
e
M
o
del N
o
:
YX
1
5
P
Revi
s
ion
Date
:
23
-
Mar-2007 She
e
t
1
of
1
F
il
e
:
P-200FATONE-OLD.
S
ch
Draw
n
B
y
:
D
ECH
UN
QIN
1
2
3
4
5
6
7
8
9
C
N2
2
.5
4
9
P
1
3
1
2
1
4
IC2
D
TL0
74CN
9
1
0
8
IC2
C
TL0
7
4CN
6
5
7
IC2
B
T
L
0
7
4CN
2
3
1
IC2
A
T
L
0
74
CN
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
C
N1
2
.5
4
9
P
2
3
1
IC1
A
T
L
0
72
6
5
7
IC1
B
T
L
0
72
R2
3
1
5
K
R2
9
1
5
K
R24
15K
R22
1
5
K
R21
4
.
7
K
R2
8
1
K
R2
7
2
.2
K
R2
6
1
5
K
R13
4
.7K
C11
2
2
p
F
C2
1
2
2
p
F
C6 2
2
p
F
VR5
C1
0
K
C1
0
0
.
33uF
C1
9
2
2
p
F
R2
0
4.
7
K
C
20 22p
F
R2
5
3
3
0
R
R1
9
1.
5
K
C1
10uF/50V NP
C16
2
2
p
F
C1
7
10uF
/5
0
V NP
R
1
6
4
.7K
R1
7
4
.7K
R1
8
10
K
4 8
IC1C
TL07
2
411
I
C
2E
TL
0
74
C14
0
.
1
uF
/
50
V
C
15
0
.1
u
F
/5
0
V
C18
0
.
1uF
/5
0
V
C2
2
0
.
1u
F/5
0
V
C
1
2
1
0
u
F
/
5
0V
C1
3
10
u
F/
5
0
V
+
15V
-1
5
V
+
1
5
V
-
1
5V
V
R1
B5K
R4
4.
7
K
R14
2
2
K
C
2 2
2
pF
R1
5
2
2K
C
3
1
0
u
F
/
5
0
V N
P
V
R2
B1
0
K
V
R3
B1
0K
V
R4
B1
0K
R
10
4.
7K
R1
1
4.
7
K
R7
2
.
7
K
R9
2.
7
K
R5
10K
R6
1
0
K
R
8
1
0K
R
12
1
2K
C7
0
.
005
6
u
F
/
5
0
V
C9
0
.
01
8
u
F
/
5
0V
C8 2
2
p
F
R
3
0
1
0K
R
2
3
30R
T
R
1
B
C559C
R1
3
3
0
R
C5
0
.
0
0
6
8
u
F/50V
C
4
0.
0
4
7
u
F
/
5
0V
1
2
R3
1
.
5K
3
4
1
2
DL1
VTL
5
C4
From INPUT JACK PCB CN1 P-200FAPRE PCB
To CN2 P-200FRC PCB
P-200FATONE (1/1)
A4
Schematic-YX15P-200FATONE-BOARD-CIR-00-V000000.pdf
1 2
3 4
A
B
C
D
4
3
2
1
D
C
B
A
P-200FRC
Tit
e
l
Size M
o
del N
o
:
YX15
P
Revi
s
ion
VER
0
1120
8
Date: 23-Mar-
2
007 She
e
t 1of
1
File:
YX15P-200FRC.S
C
H
D
r
a
w
n
By:
1
2
3
4
5
6
7
8
CN2
5
6
7
IC2B
T
L
07
4
CN
C8
0
.
47
U/6
3
V
C9
0.4
7
U/63V
R1
0
18
K
R
9
3K
C3
0.33uF/63V
C7
0.47U/63V
R5
3
K
R7
1
8K
10
9
8
I
C
2
C
T
L0
7
4
C
N
T
R1
BC5
5
9
C
D
4
1
N4
14
8
R3
8
1
0
K
R2
7
3
3
0 3
2
1
IC5A
TL
0
7
2
CN
T
R3
BC559C
TR2
BC5
5
9
C
R3
9
3
0
0
K
C3
0
10
P
R30
1
0
K
C2
0
1
0U
/
50
V
N
P
5
6
7
I
C
5
B
TL
0
72
CN
R
2
8
10
K
R2
9
1
0
K
R2
0
1
0
K
R2
5
1
0
K
R2
1
1
8
K
-15
V
+
1
5V
R4
3
5
K
1
R34
360
R
4
1
4K7
3
2
1
IC
4A
T
L
07
4CN
C3
2
0
.047
U/1
0
0V
3
%
C3
4
0
.04
7
U/1
0
0
V 3
%
R42
NC
R4
0
10K
R32
180
R
3
7
1
0K
12
13
14
IC4
D
T
L
0
7
4
CN
C3
1
0.
0
0
4
7
U
/
1
00V 3%
C33
0.
0
47U/100V 3%
R4
4
NC
R3
1
1
5
K
R2
2
15
K
10
9
8
IC4
C
T
L
0
74
CN
C2
5
0
.002
2
U/1
0
0V
3
%
C
2
1
0
.
00
4
7
U
/
1
0
0
V 3
%
R2
3
N
C
R4
5
10K
5
6
7
IC4
B
TL
074
C
N
R3
3
1
0
K
R24
1
8
K
C
2
6
2
2P
3
2
1
I
C
1
A
T
L
0
72CN
3
2
1
I
C
3A
T
L
0
7
2CN
5
6
7
IC3
B
TL07
2
CN
5
6
7
IC1B
T
L
0
72C
N
R
4
1
0
K
R17
4
7
K
C6
22
P
C1
9
2
2
P
R
3
1
0
K
R1
4
10K
R
18
1
5
0
K
R2
2
2
K
R1
2.7K
R1
6
2.
7
K
R15
4
.
7K
R1
9
1
0
C
17
0.
0
4
7
U
/
1
00V 3%
C1
5
0.01U/1
0
0V
3
%
D
2
1
N
4
148
D3
1
N
4148
D
5
1
N
4
1
4
8
D1
1N4
1
4
8
C1
10U/50V
+
1
5
V
-1
5
V
3
2
1
IC
2
A
TL
0
7
4
C
N
1
2
13
14
I
C
2D
T
L
0
7
4
CN
R
6
2
K
R8
5.
6
K
R1
1
2.
7
K
C11
0
.
00
6
8
U/1
0
0
V 3
%
C
1
2
0
.
006
8
U
/
1
0
0
V 3
%
C13
0.
0
0
4
7U/100
V
3%
R1
2
2
2K
1
2
3
4
5
6
7
8
9
10
11
1
2
CN1
-15V
+
15V
84
IC5C
T
L
0
72CN
84
IC3
C
T
L
0
72C
N
84
IC1C
TL072
CN
411
I
C
2E
T
L074
CN
411
IC4E
T
L0
7
4CN
C4
0.
1
U/5
0
V
C2
2
0.
1
U/5
0
V
C
2
0
.
1U/50V
C
1
6
0
.
1U/5
0V
C
2
4
0
.
1U/5
0
V
C5
0.1U/5
0
V
C2
7
0
.
1U/5
0
V
C1
0
0.
1
U/50V
C1
8
0
.1
U/50V
C2
3
0
.
1
U
/50V
+
15V
-15V
R2
6
10K
+1
5
V
R13
N
C
C
14
0
.
0
1
5
U
/
1
0
0V
3
%
+
1
5V
-1
5
V
C2
9
0
.
1
U
/
5
0
V
C2
8
NC
R3
6
NC
-1
5
V
R3
5
N
C
J
U
MP
ER
From CN1 P-200FATONE-BOARD-CIR
To CN1 P-200AMP PCB
Schematic-YX15P-200FRC-BOARD-CIR-00-V011208.pdf
A4
1 2 3 4
A
B
C
D
4
3
21
D
C
B
A
20
0F
A
P
RE
T
ite
l
Siz
e
M
o
del N
o
:
Y
X15
P
R
e
v
ision
V
E
R061
11
3
D
a
t
e:
1
7-
Ma
r-2
00
7 Sh
e
e
t 1
of
1
F
il
e
:
2
0
0FA
P
RE
.
Sc
h
Draw
n
B
y
:
1 2
3
S
3
OUT
1 2
3
S
1
M
IC IN
1 2
3
S
2A
LIN
E IN
6
5
4
S2B
R3
3
3
0
R
R4
330
R
D8
15
V
D
5
1
5
V
D7
1
5
V
D
6
15V
C3
2
2
pF
R6
10R 1/2W
R11
10K
C1
0.01uF/400V
S
S
W S
P
DT
S4
P-250
R3
1
5
V
R4
1
5V
D4
15
V
D
1
1
5
V
D3
1
5
V
D
2
15V
C2
2
2
pF
R5
1
.
2
K
R10
1
.2
K
1
2
3
4
5
6
7
8
9
CN1
2.
5
4 9P
1
2
3
4
C
N
2
2.
54
4
P
1
2
3
RE
D
G
RN
D
L
1
S
IGN
A
L
/
C
OM
P
D
L
2
P
O
WE
R
T
R2
BC
55
9C
T
R
1
BC
550
C
C4
0.1uF/400V
R1
2
10K
R13
10
K
R
7
1
K
R8
2
.
7
K
R9
2
.
7
K
C
5
1
uF
/5
0
V
-1
5
V
To CN2 P-200FATONE-BOARD-CIR
Schematic-YX15P-200FAPRE-RoHS-00-V061113.pdf
A4
1 2 3 4
A
B
C
D
4
3
21
D
C
B
A
P
-
2
0
0
F
A
TONE
Titel
S
i
ze Mode
l
No:
YX15P
Revi
s
ion
VER061203
Dat
e
:
1
7-Ma
r
-20
0
7 Sheet
1
of
1
File
:
P
-2
0
0FAT
ON
E
.S
ch
D
r
awn
B
y:
D
ECHUN QIN
1
2
3
4
5
6
7
8
9
CN
2
2
.
5
4 9
P
1
3
1
2
1
4
IC2
D
T
L0
7
4
CN
9
10
8
IC2
C
TL0
74CN
6
5
7
IC2B
T
L074C
N
2
3
1
IC2
A
T
L
0
7
4
C
N
From INPUT JACK PCB CN1 P-200FAPRE PCB
To CN2 P-200FRC PCB
P-200FATONE (1/1)
A4
Schematic-YX15P-200FATONE-BOARD-CIR-RoHS-00-V061203.pdf
1
2
3
4
5
6
7
8
9
10
11
12
CN1
2.5
4 9
P
2
3
1
IC1A
T
L0
7
2
6
5
7
IC1B
T
L
0
72
R2
3
1
5
K
R2
9
1
5K
R2
4
1
5
K
R
2
2
15
K
R
2
1
4.
7
K
R2
8
1
K
R2
7
2
.2
K
R2
6
1
5
K
R
1
3
4.
7
K
C1
1
22pF
C2
1
2
2
p
F
C6 2
2
p
F
V
R5
C
1
0
K
C10
0.
3
3
u
F
C
19
2
2pF
R2
0
4.
7
K
C
2
0
2
2
pF
R2
5
3
3
0
R
R1
9
1
.5K
C1
10uF/50V NP
C
1
6
2
2pF
C1
7
10
u
F/
5
0V
N
P
R16
4
.
7
K
R
17
4
.7K
R1
8
1
0
K
4 8
IC1
C
TL0
7
2
411
I
C
2E
TL07
4
C14
0
.1u
F
/
50
V
C
1
5
0
.
1
u
F/
5
0
V
C18
0.1
u
F/
5
0V
C
22
0.
1
uF
/
50V
C1
2
1
0
uF
/
50V
C13
1
0
u
F
/5
0V
+15
V
-
15V
+
1
5V
-15
V
V
R
1
B5
K
R4
4
.
7K
R14
22K
C2 22
pF
R
1
5
2
2
K
C3
1
0
u
F
/
5
0
V NP
V
R2
B
1
0K
V
R3
B
10
K
V
R
4
B
10K
R10
4
.
7
K
R1
1
4.
7
K
R7
2
.
7K
R9
2.
7
K
R
5
10
K
R6
1
0
K
R8
10K
R1
2
1
2
K
C
7
0
.
0056
u
F
/
5
0
V
C9
0
.
018
u
F
/
5
0
V
C8 2
2pF
R30
1
0K
R2
33
0R
1
2
3
4
5
6 11
U1
0
0A
L
M
1
3
600
16
1
5
1
4
1
3
12
U
100B
L
M
136
0
0
R1
0
4
6
.
8K
R1
05
6.
8
K
R1
0
6
6
.
8K
R1
07
6
.
8K
R1
09
10K
R1
1
0
1
5
K
R1
11
24
9
R
R1
1
2
2
4
9
R
R1
1
4
1
5
K
R1
15
24
9R
R11
6
249
R
R
1
1
3
1
0K
+1
5V
+1
5V
T
R
1
B
C
55
9
C
Q
1
0
0
BC5
5
9
C
Q10
1
BC55
0
+
1
5V
R10
2
5
6
K
R
1
01
3
.9
K
+1
5
V
R
1
3
3
0
R
R1
0
0
2
2
K
7
8
10
9
U
100C
L
M
13
60
0
R1
08
47
K
C1
00
4
7
uF
/
50
V
-1
5
V
R
10
3
1
K
+
15
V
-15V
C5
0
.
00
6
8
u
F
/
50V
C4
0
.0
4
7
u
F
/
5
0V
1 2
3 4
A
B
C
D
4
3
2
1
D
C
B
A
P-200FRC
Tit
e
l
Size M
o
del N
o
:
YX15
P
Revi
s
ion
VER
0
1120
8
Date: 23-Mar-
2
007 She
e
t 1of
1
File:
YX15P-200FRC.S
C
H
D
r
a
w
n
By:
1
2
3
4
5
6
7
8
CN2
5
6
7
IC2B
T
L
07
4
CN
C8
0
.
47
U/6
3
V
C9
0.4
7
U/63V
R1
0
18
K
R
9
3K
C3
0.33uF/63V
C7
0.47U/63V
R5
3
K
R7
1
8K
10
9
8
I
C
2
C
T
L0
7
4
C
N
T
R1
BC5
5
9
C
D
4
1
N4
14
8
R3
8
1
0
K
R2
7
3
3
0 3
2
1
IC5A
TL
0
7
2
CN
T
R3
BC559C
TR2
BC5
5
9
C
R3
9
3
0
0
K
C3
0
10
P
R30
1
0
K
C2
0
1
0U
/
50
V
N
P
5
6
7
I
C
5
B
TL
0
72
CN
R
2
8
10
K
R2
9
1
0
K
R2
0
1
0
K
R2
5
1
0
K
R2
1
1
8
K
-15
V
+
1
5V
R4
3
5
K
1
R34
360
R
4
1
4K7
3
2
1
IC
4A
T
L
07
4CN
C3
2
0
.047
U/1
0
0V
3
%
C3
4
0
.04
7
U/1
0
0
V 3
%
R42
NC
R4
0
10K
R32
180
R
3
7
1
0K
12
13
14
IC4
D
T
L
0
7
4
CN
C3
1
0.
0
0
4
7
U
/
1
00V 3%
C33
0.
0
47U/100V 3%
R4
4
NC
R3
1
1
5
K
R2
2
15
K
10
9
8
IC4
C
T
L
0
74
CN
C2
5
0
.002
2
U/1
0
0V
3
%
C
2
1
0
.
00
4
7
U
/
1
0
0
V 3
%
R2
3
N
C
R4
5
10K
5
6
7
IC4
B
TL
074
C
N
R3
3
1
0
K
R24
1
8
K
C
2
6
2
2P
3
2
1
I
C
1
A
T
L
0
72CN
3
2
1
I
C
3A
T
L
0
7
2CN
5
6
7
IC3
B
TL07
2
CN
5
6
7
IC1B
T
L
0
72C
N
R
4
1
0
K
R17
4
7
K
C6
22
P
C1
9
2
2
P
R
3
1
0
K
R1
4
10K
R
18
1
5
0
K
R2
2
2
K
R1
2.7K
R1
6
2.
7
K
R15
4
.
7K
R1
9
1
0
C
17
0.
0
4
7
U
/
1
00V 3%
C1
5
0.01U/1
0
0V
3
%
D
2
1
N
4
148
D3
1
N
4148
D
5
1
N
4
1
4
8
D1
1N4
1
4
8
C1
10U/50V
+
1
5
V
-1
5
V
3
2
1
IC
2
A
TL
0
7
4
C
N
1
2
13
14
I
C
2D
T
L
0
7
4
CN
R
6
2
K
R8
5.
6
K
R1
1
2.
7
K
C11
0
.
00
6
8
U/1
0
0
V 3
%
C
1
2
0
.
006
8
U
/
1
0
0
V 3
%
C13
0.
0
0
4
7U/100
V
3%
R1
2
2
2K
From CN1 P-200FATONE-BOARD-CIR
To CN1 P-200AMP PCB
Schematic-YX15P-200FRC-BOARD-CIR-00-RoHS-V011208.pdf
A4
1
2
3
4
5
6
7
8
9
10
11
1
2
CN1
-15V
+
15V
84
IC5C
T
L
0
72CN
84
IC3
C
T
L
0
72C
N
84
IC1C
TL072
CN
411
I
C
2E
T
L074
CN
411
IC4E
T
L0
7
4CN
C4
0.
1
U/5
0
V
C2
2
0.
1
U/5
0
V
C
2
0
.
1U/50V
C
1
6
0
.
1U
/
5
0V
C
2
4
0
.
1U/5
0
V
C5
0.1U/5
0
V
C2
7
0
.
1U/5
0
V
C1
0
0.
1
U/50V
C1
8
0
.1
U/50V
C
2
3
0
.1U/50V
+
15V
-15V
R2
6
10K
+1
5
V
R13
N
C
C
14
0
.
0
1
5
U
/
1
0
0V
3
%
+
1
5V
-1
5
V
C2
9
0
.
1
U
/
5
0
V
C2
8
NC
R3
6
NC
-1
5
V
R3
5
N
C
J
U
MP
ER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

YORKVILLE YX15P User manual

Category
Audio amplifiers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages