Cooper Lighting MS185W User manual

Category
Floodlights
Type
User manual
Instruction Manual/Instrucciones
Questions?/¿Preguntas? 1-800-334-6871 [email protected]
1
•Disassemblyofyourxturewillvoidthewarranty.
•Yourxtureisprewiredandpreassembledforeasyinstallation.
•MINIMUM90°CSUPPLYCONDUCTORS.
•ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowing
twoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemust
acceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
UnderPart15oftheFCCRules,anychangesormodicationstothemotiondetector
describedinthisinstructionsheetthatarenotexpresslyapprovedbyCooperLighting,LLC
couldvoidtheuser’sauthoritytooperatetheequipment.
NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassB
digitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.This
equipmentgenerates,usesandcanradiateradiofrequencyenergyandifnotinstalled
andusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticular
installation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,
whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotryto
correcttheinterferencebyoneormoreofthefollowingmeasures:
-Reorientorrelocatethereceivingantenna.
-Increasetheseparationbetweentheequipmentandreceiver.
-Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiver
isconnected.
-Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
WARNING: FCC Regulations state that any unauthorized changes or modifications
to this equipment not expressly approved by the manufacturer could void the user’s
authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.
FOR BEST RESULTS
•Installthemotionsensor/transmitter8-12feet
abovetheground.(Motionsensorislesssensitive
above12feet.)
•Locatemotionsensorsomotionmovesacross
detectionzone(Fig.1).
•Locatesensorawayfromheatproducingsourcesto
preventfalsetriggering.Alsobeverycarefulnotto
includeobjectssuchaswindows,whitewallsand
waterinthedetectionzone.
•Locatesensorawayfrommovingobjectssuchas
trees,largeshrubsandstreettrafc.
•Donotinstallmorethanonemotionactivated
oodlightononewallswitch.
PACKAGING CONTENTS/CONTENIDO DEL PAQUETE
ITEMS REQUIRED
(Purchase separately)
•Phillipsscrewdriver
•Outdoorweatherproofsiliconecaulking
•(2)100watt(MAX)PAR38oodlightbulbs
NOTE:Thisxturewasdesignedtoworkwithupto150wattmaximumPARhalogenood
bulbs.Forimprovedenergyefciency,lowerwattagePARhalogenoodbulbsmaybeused.
CompactFluorescent(CFL)bulbscontainelectronicswhichmayinterferewiththemotion
sensingfunctionofyourxtureandarenotrecommended.TomeetENERGYSTAR
®
requirements,maximumlampwattagecannotexceed250watts.
HOW IT WORKS
Yourmotionactivatedoodlightsensesheatimagesfrom
objectssuchaspeople,largeanimalsandautomobileengines.
Whenmotionisdetected,thelightswillautomaticallyturn
on.Oncemotionhasstopped,thelightswillturnoffaftera
preselectedtimedelay.Yourmotionactivatedoodlightmay
alsobeusedasastandardoodlight.
WARNINGS AND CAUTIONS
•Readtheseinstructions.
•Keeptheseinstructions.
•Heedallwarnings.
•Followallinstructions.
•Foroutdooruseonly.
•cULusLISTEDforwetlocations.
•Connectxturetoa120volt,60Hzpowersource.Anyotherconnectionvoidsthewarranty.
•Fixtureshouldbemountedtoagroundedrecessedmountedstandardjunctionboxmarked
foruseinwetlocations.
•Suitableforwallmountoreavemountonly.NOTsuitableforgroundmountinstallation.
•Donotallowsensorheadtotouchlighthousing–maintainatleast1in.spacebetween
xtureandsensor.
•Fixtureshouldbeinstalledbypersonswithexperienceinhouseholdwiringorbyaqualied
electrician.Theelectricalsystem,andthemethodofelectricallyconnectingthexturetoit,
mustbeinaccordancewiththeNationalElectricalCodeandlocalbuildingcodes.
•Alwaysreplacebulbwiththesamewattageorlowerwattagethanincluded.Installinga
bulbofahigherwattagecouldcreatearehazard.Useofahigherwattagebulbwillvoid
thewarranty(maximum150watthalogenbulb).TomeetENERGYSTAR
®
requirements,
maximumlampwattagecannotexceed250watts.
•Forproperoperationandprotectionagainstdamage,themotion
sensorheadadjustmentknobsmustbefacingtheground.
•Keepawayfromammableobjects.Donotpositionxturewithin2in.
ofanycombustiblematerials.
MS185 (Bronze)
MS185W (White)
A. Motion detector
and light fixture
Detector de
movimiento y
artefacto de luz
ENGLISH
Upto
70feet
180degrees
D. (2) #6 and (2) #8 mounting screws
(use the size that fits your junction box)
(2) Tornillos #6 y (2) tornillos #8 de montaje
(utilice el tamaño que mejor se adecue a
su caja de conexión)
B. Coverplate gasket
Junta de la placa
de cubierta
E. (3) Wire nuts
(3) Tuercas
para alambre
C. (2) Lampholder gaskets
(2) Juntas obturadoras
del receptáculo
F. Color-matched
center hole plug
Tapón para agujero
central de color
coincidente
G. Center bolt
Perno central
H. Mounting bracket
Soporte de montaje
Fig.1
2
SELECTING YOUR DESIRED FEATURE
TROUBLESHOOTING
MOUNTING AND WIRING YOUR FIXTURE
WARNING: Risk of electric shock. Disconnect
power at fuse or circuit breaker before installing
or servicing.
NOTE:Fixturecanbewalloreavemounted.
NOTE:Coverplatemountstorecessedmounted
standardjunctionboxes(Fig.2).Junctionboxmustbe
atleast1-1/2in.indepthforproperinstallationfor
recessedmountapplication.
1. Lineuptheholesonthemountingbracket(H)with
theholesonyourjunctionbox.Usingeither(2)#6
screwsor(2)#8screws(D)(dependingonsizeof
theholesinyourjunctionbox),attachthemounting
bracket(H)toyourjunctionbox(Fig.3).
2. Threadxturewiresthroughcoverplategasket(B)
(Fig.4).
3. Connectxtureblackwiretohouseblackwire,
xturewhitewiretohousewhitewire,andcopper
coloredgroundwire(comingfromthexture
coverplate)tohousegroundwireusingwirenuts
(E)provided.
4. Attachxture(A)tothemountingbracket(H)using
thecenterbolt(G)provided.Besurenoloosewires
remainstickingoutfromunderneaththecoverplate.
Insertplasticcolor-matchedplug(F)incenterbolt
holefornishedappearance(Fig.5).
5. Applysiliconecaulkaroundtheedgesofthe
coverplatetoprovideawatertightsealfromrain
andmoisture.
6. Insertlampholdergaskets(C)intolampholder
assembly,tightlyagainstlampholder,andscrew
bulbsintoeachlampholder(Fig.6).(Donot
overtightenbulbs.)
7. Turnonpoweratmainfuse/breakerbox.
OPERATING YOUR FIXTURE
1. Moveslideswitchonbottomofthesensor
to“TEST”.Setsensitivityknobtomedium
(halfway)(Fig.7).
2. Turnonthepowertoxture.Allowxturetowarm
upapproximately40secondsbeforetesting.(Lights
maynotcomeonduringwarm-upperiod.)
3. Aimsensorheadtowarddesireddetectionarea,
maintaininga15°downangletoallowmoisture
todrain.
NOTE:Maintainairspacingbetweenlampsandsensor
head,atleast1in.Makesuresensorheadispositioned
withcontrolswitchesfacingtowardstheground.
4. Walkacrossthedetectionzoneatthefarthest
distanceyouwishyourdetectortodetectmotion.
5. Adjustsensitivityuntilyougetdesiredresults.Light
willturnoff4secondsafterallmotionstops.
NOTE:Formaximumrangeperformance,allowxture
tooperateinanymode(withpowertotheunit)forat
least48hours.
6. Moveslideswitchto4min.or12min.(AUTO
mode).AtdusklightswilloperateintheAUTO
setting.
ENERGY STAR
®
TomeetENERGYSTAR
®
requirements,thephotosensorcontrolknobmustbeinthe
“Auto”modetopreventoperationduringfulldaylight.Maximumlampwattagecannot
exceed250watts.
Fig.2
OctagonalRound
-
+
TEST 4 MIN. 12 MIN.
SENSITIVITY
Fig.7
Mode of MODE Knob How to Set
Operation Adjustment Power Switch
Test Setting
LightsshouldturnONwith
motionbothdayandnight.
LightsshouldturnOFF
after4seconds.
Keepthepower
tothextureON.
TEST
Auto” Setting
(motion activated)
LightsshouldturnONwith
motiononlyatnightand
shouldturnOFFafter
4-12minutesofnomotion.
AUTO4MIN
or
AUTO12MIN
Keepthepower
tothextureON.
Dusk-to-Dawn Setting
(activated only at night)
LightsshouldstayONfrom
dusktodawnandthenreset
to“Auto”settingat
thenextdawn.
AUTO4MIN
or
AUTO12MIN
Turnthepower
OFF-ON-OFF-ON
within3seconds.
Return to “Auto”
(motion activated) Setting
from any of
the above settings.
AUTO4MIN
or
AUTO12MIN
TurnthepowerOFF
foratleast40seconds
andthenbackON.
Standard Floodlight Setting
LightsshouldstayON
continuouslybothdayandnight
(mustberesetmanually).
TEST Turnthepower
OFF-ON-OFF-ON
within3seconds.
Problem Cause / Solution
Outdoor Light
Does Not Come
On With Motion
At Night
Nopowertothexture.
• Checkifcircuitbreakertripped.
• ConrmwallswitchisON.
Bulbisfaulty.
•Replacebulb.
Surroundingexternalambientlightistoobright.(Ifso,theunitmay
thinkitisdaytime.)
• Re-aimthehead.
• Relocateorrepositiontheunitawayfromthelight.
TURN OFF POWER BEFORE CONTINUING
Wiringtotheunitisloose.
• Checkwiring,andreconnectifnecessaryusingwire
nuts(E)provided.
Outdoor Light
Comes On For No
Apparent Reason
At Night
Thereismotioninthedetectionzone.
• Makesurethesensorisnotpickingupmovingobjectssuchas
trees,trafc,etc.
TEST FOR YOURSELF.
• Coverthesensorlenswithcardboardtopreventsensorfrom
detectingmotion.Ifthelightstaysoff,somethinginthedetection
zoneistriggeringthesensor.
•Ifthisisthecase,reducethesensitivity.
• Repositionthesensor.
*Ifthelightstaysonwiththesensorlenscovered,contact
customerservice.
Light Stays On At
Night And Does
Not Turn Off
Thereismotioninthedetectionzone.
• Makesurethesensorisnotpickingupmovingobjectssuchas
trees,trafc,etc.
• Reducethesensitivity.
• Repositionthesensor.
Unitisinoverridemode(ifthereisnomotion).
• TurnthelightswitchtotheOFFpositionfor40seconds,andthen
turnbacktotheONposition.Thiswillsendtheunitbackintothe
“Auto”mode.
*Ifthelightstaysonwiththesensorlenscovered,contact
customerservice.
Light
Continuously
Blink On and
Off At Night
Thelightgivenfromtheunit’sownlampisaffectingthe
motionsensor.
• Re-aimthelamp.
• Repositionmotionsensor.
Fig.3
D
H
D
Fig.5
F
G
A
Fig.6
C
C
Wallmount
Eavemount
Fig.4
B
A
A
E
E
E
ENERGYSTAR
®
issponsoredbytheU.S.
EnvironmentalProtectionAgency&U.S.
DepartmentofEnergy.
Visitwww.energystar.govtolearnmore.
1-1/2in. 1-1/2in.
3
Light Is On
During The Day
Thecontrolsonthebottomofthemotionsensorareinthetestmode.
• MovetheswitchtotheAUTO4or12position.
Themotiondetectorisshadowed.
• Repositionmotionsensor.
Cannot Activate
Dusk to Dawn
Mode At Night
(Override)
Surroundingexternalambientlightistoobright.(Ifso,theunitmay
thinkitisdaytime.)
• Re-aimthehead.
• Relocateorrepositiontheunitawayfromthelight.
Notenoughtimeisallowedtoenterthedusktodawnmode.
• TurnpowerOFF-ON-OFF-ONwithin3seconds.
Thereismorethanonextureonanindoorwallswitch.
• Ifso,putthemonseparateswitches.
2-YEAR LIMITED WARRANTY
THEFOLLOWINGWARRANTYISEXCLUSIVEANDINLIEUOFALLOTHERWARRANTIES,
WHETHEREXPRESS,IMPLIEDORSTATUTORYINCLUDING,BUTNOTLIMITEDTO,ANY
WARRANTYOFMERCHANTABILITYORFITNESSFORANYPARTICULARPURPOSE.
CooperLighting,LLC(“CooperLighting”)warrantstocustomersthat,foraperiodoftwoyears
fromthedateofpurchase,CooperLighting’sproductswillbefreefromdefectsinmaterials
andworkmanship.TheobligationofCooperLightingunderthiswarrantyisexpresslylimited
totheprovisionofreplacementproducts.Thiswarrantyisextendedonlytotheoriginal
purchaseroftheproduct.Apurchaser’sreceiptorotherproofofdateoforiginalpurchase
acceptabletoCooperLighting.Thisisrequiredbeforewarrantyperformanceshallberendered.
ThiswarrantydoesnotapplytoCooperLightingproductsthathavebeenalteredorrepaired
orthathavebeensubjectedtoneglect,abuse,misuseoraccident(includingshippingdamages).
ThiswarrantydoesnotapplytoproductsnotmanufacturedbyCooperLightingwhichhavebeen
supplied,installed,and/orusedinconjunctionwithCooperLightingproducts.Damagetothe
productcausedbyreplacementbulbsorcorrosionordiscolorationofbrasscomponentsare
notcoveredbythiswarranty.
LIMITATIONOFLIABILITY:
INNOEVENTSHALLCOOPERLIGHTINGBELIABLEFORSPECIAL,INDIRECT,INCIDENTAL,OR
CONSEQUENTIALDAMAGES(REGARDLESSOFTHEFORMOFACTION,WHETHERINCONTRACT,
STRICTLIABILITY,ORINTORTINCLUDINGNEGLIGENCE),NORFORLOSTPROFITS;NORSHALL
THELIABILITYOFCOOPERLIGHTINGFORANYCLAIMSORDAMAGEARISINGOUTOFOR
CONNECTEDWITHTHESETERMSORTHEMANUFACTURE,SALE,DELIVERY,USE,MAINTENANCE,
REPAIRORMODIFICATIONOFCOOPERLIGHTINGPRODUCTS,ORSUPPLYOFANYREPLACEMENT
PARTSTHEREFORE,EXCEEDTHEPURCHASEPRICEOFCOOPERLIGHTINGPRODUCTSGIVINGRISE
TOACLAIM.NOLABORCHARGESWILLBEACCEPTEDTOREMOVEORINSTALLFIXTURES.
Toobtainwarrantyservice,pleasecontactCooperLighting,LLC,at1-800-334-6871,press
option2forCustomerService,orviae-mail[email protected]and
includethefollowinginformation:
•Name,addressandtelephonenumber
•Dateandplaceofpurchase
•Catalogandquantitypurchase
•Detaileddescriptionofproblem
AllreturnedproductsmustbeaccompaniedbyaReturnGoodsAuthorizationNumberissued
bytheCompanyandmustbereturnedfreightprepaid.AnyproductreceivedwithoutaReturn
GoodsAuthorizationNumberfromtheCompanywillberefused.
CooperLighting,LLCisnotresponsibleformerchandisedamagedintransit.Repairedor
replacedproductsshallbesubjecttothetermsofthiswarrantyandareinspectedwhen
packed.Evidentorconcealeddamagethatismadeintransitshouldbereportedatonceto
thecarriermakingthedeliveryandaclaimledwiththem.
ReproductionsofthisdocumentwithoutpriorwrittenapprovalofCooperLighting,LLCarestrictlyprohibited.
For assistance, call 1-800-334-6871 or e-mail us at [email protected]
PrintedinChina
ARTÍCULOS NECESARIOS
(se compran por separado)
•Destornilladorencruz(Phillips)
•Calafateodesiliconaresistentealaintemperie
•(2)lámparasparaproyectortipoPAR38de100W(máximo)
NOTA:EsteaccesoriofuediseñadoparatrabajarconbombillasreectorasdeHalógenoPARde
150vatioscomomáximo.Paramayorecienciadeenergía,usebombillasreectoras
HalógenoPARdemenorvataje.Noserecomiendaelusodebombillasuorescentes
compactas(CFL)porquetienenparteselectrónicasquepuedeninterferirconlasfunciones
dedeteccióndemovimientodesuaccesorio.ParacumplirconlosrequerimientosdeENERGY
STAR
®
,lapotenciamáximadelabombillanodebeexceder250W.
CÓMO FUNCIONA
Lalámparadealtaintensidadactivadapormovimiento
detectaimágenestérmicasdeobjetostalescomo
personas,animalesgrandesymotoresdeautomóviles.
Problem Cause / Solution
ESPAÑOL
Cuandosedetectemovimiento,laluzseencenderá
automáticamente.Unavezqueelmovimientohaya
cesado,laluzseapagarádespuésdeuntiempode
retardopreseleccionado.Estalámparadealtaintensidad
activadapormovimientotambiénpuedeserutilizada
comounalámparadealtaintensidadestándar.
ADVERTENCIAS Y PRECAUCIONES
•Leaestasinstrucciones.
•Guardeestasinstrucciones.
•Atiendatodaslasadvertencias.
•Sigatodaslasinstrucciones.
•Sóloparausoenexteriores.
•cULusparaubicacionesmojadas.
•Elportalámparasdebeestarconectadoaunafuentedeenergíade120Voltios,60Hz.
Cualquierotrotipodeconexiónanulalagarantía.
•Debemontarelartefactosobreunacajadeconexionesempotradascontomade
tierramarcadaparausarenlugareshúmedos.
•Adecuadoparainstalarseenlaparedoenalerossolamente.Noesadecuadopara
instalarsemontándoloenelsuelo.
•Nopermitaqueelsensortoqueelalojamientodelalámpara–mantengaporlomenos
1pulgada(2,54cm)deespacioentreelportalámparasyelsensor.
•Elportalámparasdebeserinstaladoporpersonasconexperienciaencableado
domésticooporunelectricistacalicado.Elsistemaeléctricoyelmétododeconexión
eléctricadelportalámparasdebecumplirconelCódigoeléctriconacionalyloscódigos
localessobreedicios.
•Reemplacesiemprelabombillaconunadelmismovatiajeomásbajoqueelmarcado.Si
instalalámparasdemayorpotencia,puedecrearriesgodeincendio.Siusalámparasde
mayorpotencia,seanulalagarantía.(Utiliceunabombilladehalógenodeunmáximode
150W.)ParacumplirconlosrequerimientosdeENERGYSTAR
®
,lapotenciamáximadela
bombillanodebeexceder250W.
•Paraunfuncionamientoyprotecciónadecuadoscontraposiblesdaños,losbotonesde
ajustedelacabezadelsensordemovimientosedebenajustarendirecciónalpiso.
•Manténgaloalejadodeobjetosinamables.Nocoloqueelartefactoen
posicióndentrode2pulgadas(5cm)decualquiermaterialcombustible.
•Sidesarmaelartefacto,seanulalagarantía.
•Lalámparaespercableadayensambladoparafacilitarlainstalación.
•UTILICECONDUCTORESDESUMINISTROQUESOPORTENUNMÍNIMODE90°C.
•EstedispositivocumpleconlaParte15delasReglasdelaComisiónFederalde
Comunicaciones(FCC)delosE.U.deA.Laoperaciónestásujetaalasdoscondiciones
siguientes:(1)Estedispositivonopuedecausarinterferenciadañina,y(2)estedispositivo
debeaceptartodainterferenciarecibida,incluyendolainterferenciaquepuedacausarun
funcionamientoindeseado.SegúnlaParte15delasReglasdelaFCC,todocambioo
modicaciónaldetectordemovimientodescriptoenestahojadeinstruccionesqueno
estéexpresamenteaprobadoporCooperLighting,LLCpodríaanularlaautorizacióndel
usuarioparaoperarelequipo.
NOTA:Esteequipohasidoprobado,ysehavericadoquecumpleconloslímitesdeun
dispositivodigitalClaseB,deacuerdoconlaParte15delasReglasdelaFCC.Estoslímites
estándiseñadosandeproveerunaprotecciónrazonablecontralainterferenciadañina
enunainstalaciónresidencial.Esteequipogenera,usaypuedeirradiarenergíaderadio
frecuencia,ysinoseinstalayutilizadeacuerdoconlasinstrucciones,puedecausar
interferenciadañinaenlascomunicacionesderadio.Sinembargo,nosegarantizaqueno
vayaaproducirseinterferenciaenunainstalaciónenparticular.Siesteequipoefectivamente
causaunainterferenciadañinaenlarecepciónderadiootelevisión,loquepuede
determinarseapagándoloyencendiéndolo,serecomiendaalusuarioquetratedecorregir
lainterferenciapormediodeunaomásdelassiguientesmedidas:
-Reorienteocambiedelugarlaantenareceptora.
-Aumentelaseparaciónentreelequipoyelreceptor.
-Conecteelequipoenuntomacorrientequeestéenuncircuitodiferentedeaquélalque
seconectaelreceptor.
-Consulteasuproveedor,oauntécnicoderadio/TVexperimentado,paraqueleayuden.
ADVERTENCIA: Las Reglamentaciones de la FCC establecen que todo cambio o
modificación no autorizados en este equipo, que no estén aprobados expresamente por
el fabricante, podrían anular la autorización del usuario para operar el equipo.
GUARDE ESTAS INSTRUCCIONES.
PARA OBTENER LOS MEJORES RESULTADOS
•Instaleelsensordemovimiento/transmisora
8–12pies(2,45–3,65m)dealturasobreelsuelo
(porencimade12pies/3,65m,elsensorde
movimientoesmenossensible).
•Coloqueelportalámparasdemaneraquesemueva
portodalazonadedetección(Fig.1).
•Coloqueelsensorlejosdefuentesqueproduzcan
calor,andeevitarfalsosdisparos.Además,medida
deloposible,tengamuchocuidadodenoincluir
objetostalescomoventanas,paredesblancasy
agua,enlazonadedetección.
Hasta
70pies
180grados
Fig.1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Cooper Lighting MS185W User manual

Category
Floodlights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages