7080-359-02_C16_CI16_CS16Instal_3Lang.qxd 9/7/2004 8:58 AM Page 18
Installation
Instructions
For Built-In NoFrost Combined
Refrigerator-Freezers
Instructions
de montage
Pour le combiné réfrigérateur-
congélateur NoFrost encastrable
Instrucciones
de instalación
Para conbinados frigorífico-
congelador NoFrost empotrables
C 16
CI 16
7080 359-02
7080-359-02_C16_CI16_CS16Instal_3Lang.qxd 9/7/2004 8:58 AM Page i
IMPORTANT
C 16/CI 16
A delight in freshness
PLEASE READ AND FOLLOW
THESE INSTRUCTIONS
These instructions contain Warning and Caution
statements.This information is important for safe
and efficient installation.
Always read and follow all Warning and Caution
statements!
States a hazard that may cause serious
injury or death if precautions are not
followed.
Signals a situation where minor injury of
product damage may occur if you do not
follow instructions.
IMPORTANT
This highlights information that is especially
relevant to a problem-free installation.
Make sure incoming voltage is the same as the unit
rating.
To reduce the risk of fire, electric shock, or personal
injury, installation work and electrical wiring must be
done by a qualified electrician in accordance with
all applicable codes and standards, including fire-
rated construction.
TO THE INSTALLER
It is very important that the guidelines and
instructions are followed in the manual to ensure
proper installation and operation of the unit.The
Installation Guidelines section contains important
information for making sure the installation is
correct. Read and understand all the information in
Installation Guidelines, and in this manual before
the unit is installed.
CAUTION
!
!
WARNING
7080-359-02_C16_CI16_CS16Instal_3Lang.qxd 9/7/2004 8:58 AM Page ii
7080-359-02_C16_CI16_CS16Instal_3Lang.qxd 9/7/2004 8:58 AM Page 1
A delight in freshness
Table of Contents
1
C 16/CI 16
Contents Page
Features ....................................................................................................... 2
Installation Guidelines
Area Requirements................................................................................ 3
Electrical Requirement........................................................................... 3
Customer’s Responsibility...................................................................... 3
Blocking For Safety................................................................................ 3
Unit Venting............................................................................................ 3
Reversing the Door Hinges ................................................................... 3
Planning Information
Cabinet Opening Dimensions.................................................................4
Integrating Cabinetry
Framed Panels....................................................................................... 6
Overlay Panels....................................................................................... 7
Mounting the Upper Ventilation Grille........................................................ 10
Leveling the Refrigerator............................................................................ 11
Blocking for Safety ..................................................................................... 12
Door Stop Adjustment................................................................................ 13
Reversing Door Hinges.............................................................................. 14
Liebherr Warranty Plan.............................................................................. 17
FEATURES
2
C 16/CI 16
Figure 1
Operating and
control elements
Butter and cheese
compartment
Adjustable door racks
Adjustable shelves
Vegetable bin
Drawers
Freezing chart
Adjustable-height unit
Gallon shelf
Beverage Rack
A delight in freshness
INSTALLATION GUIDELINES
3
C 16/CI 16
Area Requirements
Verify the following:
Floors can support refrigerator’s weight plus
approximately 1200 pounds (544 kg) of food
weight.
Finish kitchen floor height is level. Refrigerator
must be shimmed to the floor level if the floor
heights are not equal to make sure air vents are
not obstructed.
Remove anything attached to rear or side walls
that can obstruct refrigerator opening.
Cutout dimensions are accurate.
Electrical outlet is in correct location.
Do not install this unit next to another refrigerator or
freezer.This is important to prevent condensation
or consequential damage from another unit.
Electrical Requirement
If codes require a separate grounding circuit to be
used, have a qualified electrician install the circuit.
Do not ground to a gas pipe. Check with a
qualified electrician if you are not sure the
appliance is properly grounded. Do not
have a fuse in the neutral or grounding
circuit.
ELECTRICAL SHOCK HAZARD
Electrically ground refrigerator.
Do not use an extension cord.
Failure to follow these instructions
could result in fire or electrical shock.
!
WARNING
!
WARNING
ELECTROCUTION HAZARD
Electrical Grounding Required.This
appliance is equipped with a three-prong
(grounding) polarized plug for your
protection against possible shock hazards.
DO NOT remove the round grounding
prong from the plug.
DO NOT use a two-prong grounding
adapter.
DO NOT use an extension cord to
connect power to the unit.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp (20 Amp for side-by-side
installation) fused electrical supply is required.We
recommend using a dedicated circuit for this
appliance to prevent electrical overload. Follow the
National Electrical Code and local codes and
ordinances when installing the receptacle.
Blocking For Safety
The anti-tip brackets must be installed to prevent
the unit from tipping after it is installed. Refer to
Blocking For Safety.
Unit Venting
DO NOT restrict the air flow. Air flow must be
provided for the unit to operate.The factory air
vents provide 31 square inches (200 cm
2
) of air
flow. If you are replacing the factory air vents with
an overlay, the air flow must be the same or greater
than the factory air vents.
Reversing the Door Hinges
If the hinges and door handles are reversed, you
must obtain the Reverse Set.The Reverse Set is
not included with the unit. Contact your Liebherr
retailer, only for CI 16 unit.The door handles must
be installed before the screw covers are installed. If
you fail to install the handles before the screw
covers, you can damage the covers.The screw
covers are taped to the unit door during shipping.
Use care when removing the covers.
!
WARNING
A delight in freshness
PLANNING INFORMATION
4
C 16/CI 16
A delight in freshness
Cabinet Opening Dimensions
Figure 2
7" (17.8 cm)
6" (15.2 cm)
29-1/2" (75 cm)
83-3/4" (212.7 cm)
24" (61 cm)
75-1/2" (192 cm)
3" (7.6 cm)
18" (45.7 cm)
LOCATE WATER SUPPLY
WITHIN BOTTOM
SHADED AREA
ELECTRICAL OUTLET
LOCATION
Allow units to open a minimum of 90° to prevent
problems removing drawers.With the door opening
90°, you may have to move drawers slightly to clear
the door interior.
Refer to the minimum door clearances in the Pre-
Installation Specifications chart.
Allow for a minimum 2" (5.08 cm) filler, for corner
installations, so the door can open to 90°. If
you’re using raised panels, consider using a
wider filler.
Use a filler strip when units are installed side by
side.The width of this filler strip will vary
depending on the configuration and panels used.
Be sure to add the filler strip width to the finished
rough-in dimension. In any side by side
installation, add an additional 1/2" (1.27 cm) to
the combined numbers.
IMPORTANT
Refer to the scaled illustrations at the end of
this section for specifics on door openings
and filler size alternatives.
PLANNING INFORMATION
5
C 16/CI 16
A delight in freshness
Figure 3
30" (76.2 cm)
83.9" (213 cm)*
24-1/2" (62 cm) - CI 16
24" (60,9 cm) - C 16
26" (66 cm)
81" (206 cm)*
90˚
130˚
29" (73.7 cm)
22.9" (58.2 cm)
30" (76.2 cm)
52.7" (134 cm)
47" (449.5 cm)
1.8" (4.6 cm)
19" (48.2 cm)
DOOR SWING CLEARANCE
Air Vent
Air Vent
* Overall height can be
increased 5/8" (1.59 cm)
by turning the adjustable
roller base.
INTEGRATING CABINETRY - CI 16 ONLY
6
C 16/CI 16
A delight in freshness
Framed Panels
If the thickness of the custom panels is less than
1/4" (0.635 cm), they must be backed up with a
sheet of shim material to build the total thickness to
1/4" (0.635 cm). If the panel is thicker than 1/4"
(0.635 cm), an edge must be routed around the
panel to ensure a proper fit.
Panels 1/4" (0.635 cm) thick or less
Trim reveal
1/4" min.
1/4" Panel
Panels thicker than 1/4" (0.635 cm)
Rout to 1/4"
thickness
Trim reveal
1/4" min.
FRAMED PANEL SPECIFICATION
28.9" (73.5 cm) 46.3" (117.6 cm)
28.4" (72.1 cm)
Refrigerator
Panel
Freezer
Panel
Figure 4
IMPORTANT
If you are replacing the factory air vents with
an overlay, DO NOT restrict the air flow.The
air flow must be the same or greater than the
factory air vents of 31 square inches (200
cm
2
).
The door handles must be installed before the
screw covers are installed. If you fail to install
the handles before the screw covers, you can
damage the covers.The screw covers are
taped to the unit doors during shipping. Use
care when removing covers.
The door panel weight must not exceed 25 lb
(11.3 kg).
INTEGRATING CABINETRY - CI 16 ONLY
7
C 16/CI 16
A delight in freshness
Overlay Panels
The overlay design line allows decorative panels to
cover the door trim for a more seamless
appearance that blends with the design of the
room.To achieve this look, the most common way
is to work with three panels, the decorative overlay
panel, a 0.10" (0.25 cm) spacer panel and a 1/4"
(0.635 cm) backer panel.
Overlay Panel 28.7" (72.9 cm)
Spacer Panel 27.4" (69.6 cm)
Backer Panel 28.2" (71.7 cm)
Overlay Panel 47.6" (120.9 cm)
Spacer Panel 45.3" (115 cm)
Backer Panel 46.3" (117.6 cm)
Overlay Panel 29.2" (74.3 cm)
Spacer Panel 27.9" (70.9 cm)
Backer Panel 28.9" (73.5 cm)
Refrigerator
Panel
Freezer
Panel
0.1" (0.25 cm)
0.0625" (0.16 cm)
0.6" (1.5 cm)
Overlay Panel
Spacer Panel
1/4" (0.635 cm)
Backer Panel
7080 010
Figure 5
Depending on your cabinet manufacturer, this could
be one panel routed for different dimensions or,
more likely, three different panels.
IMPORTANT
If you are replacing the factory air vents with
an overlay, DO NOT restrict the air flow.The
air flow must be the same or greater than the
factory air vents of 31 square inches (200
cm
2
).
The door handles must be installed before the
screw covers are installed. If you fail to install
the handles before the screw covers, you can
damage the covers.The screw covers are
taped to the unit doors during shipping. Use
care when removing covers.
The door panel weight must not exceed 25 lb
(11.3 kg).
INTEGRATING CABINETRY - CI 16 ONLY
8
C 16/CI 16
Figure 6
A = 1/4" (0.6 cm)
B = 1/2" (1.3 cm)
C = 3/4" (1.9 cm)
D = 1" (2.5 cm)
E = 1-1/4" (3.2 cm)
F = 1-1/2" (3.8 cm)
G = 1-3/4" (4.4 cm)
H = 2" (5.1 cm)
I = 2-1/4" (5.7 cm)
J = 2-1/2" (6.4 cm)
K = 2-3/4" (7.0 cm)
L = 3" (7.6 cm)
A delight in freshness
9
C 16/CI 16
A delight in freshness
INTEGRATING CABINETRY - CI 16 ONLY
The factory setting for the door to swing open is
130°. Use this illustration to ensure other cabinets
or counters do not interfere with the door opening.
Frameless cabinets:The casing trim overlaps the
cabinets at the side and top. Cabinets may require
filler strips to prevent interference with the cabinet
door swing.The door opening must allow for filler
strips.
A
B
C
D
E
F
G
H
I
J
K
L
M
L
K
J
I
H
G
H
I
J
K
L
A = 3" (7.6 cm)
B = 2-3/4" (7 cm)
C = 2-1/2" (6.4 cm)
D = 2-1/4" (5.8 cm)
E = 2" (5.1 cm)
F = 1-3/4" (4.5 cm)
G = 1-1/2" (3.8 cm)
H = 1-1/4" (3.2 cm)
I = 1" (2.5 cm)
J = 3/4" (1.9 cm)
K = 1/2" (1.3 cm)
L = 1/4" (0.6 cm)
M = 0"
23-5/8" (60 cm)
to rear of Liebherr
Nominal Overall
Width of Liebherr
Door closed
Overlay Panel
(
3/4" Nominal Size)
Door Open @ 130˚
Figure 7 - CI 16 only
INTEGRATING CABINETRY - CI 16 ONLY
10
C 16/CI 16
Figure 8
Nominal Overall
Width of Liebherr
Door Closed
Door Open 130˚
A
A
B
C
D
E
F
G
H
I
J
K
L
B
C
D
E
F
A = 1/4" (0.6 cm)
B = 1/2" (1.3 cm)
C = 3/4" (1.9 cm)
D = 1" (2.5 cm)
E = 1-1/4" (3.2 cm)
F = 1-1/2" (3.8 cm)
G = 1-3/4" (4.4 cm)
H = 2" (5.1 cm)
I = 2-1/4" (5.7 cm)
J = 2-1/2" (6.4 cm)
K = 2-3/4" (7.0 cm)
L = 3" (7.6 cm)
A delight in freshness
11
C 16/CI 16
A delight in freshness
INTEGRATING CABINETRY - CI 16 ONLY
The optional setting for the door to swing open is
90°. Use this illustration to ensure other cabinets or
counters do not interfere with the door opening.
Frameless cabinets:The casing trim overlaps the
cabinets at the side and top. Cabinets may require
filler strips to prevent interference with the cabinet
door swing.The door opening must allow for filler
strips.
23-5/8" (60 cm)
to rear of Liebherr
Main Frame
Nominal Overall
Width of Liebherr
Door closed
Door Open 90˚
Overlay Panel
(3/4" Nominal Size)
A
B
C
D
E
F
G
F
E
D
C
B
A = 0" (0 cm)
B = 1/4" (0.6 cm)
C = 1/2" (1.3 cm)
D = 3/4" (1.9 cm)
E = 1" (2.5 cm)
F = 1-1/4" (3.2 cm)
G = 1-1/2" (3.8 cm)
Figure 9 - CI 16 only
INTEGRATING CABINETRY - CI 16 ONLY
12
C 16/CI 16
Figure 10
Nominal Overall
Width of Liebherr
Door Closed
Door Open 90˚
A
A
B
C
D
E
F
G
H
I
J
K
L
B
C
D
E
F
A = 1/4" (0.6 cm)
B = 1/2" (1.3 cm)
C = 3/4" (1.9 cm)
D = 1" (2.5 cm)
E = 1-1/4" (3.2 cm)
F = 1-1/2" (3.8 cm)
G = 1-3/4" (4.4 cm)
H = 2" (5.1 cm)
I = 2-1/4" (5.7 cm)
J = 2-1/2" (6.4 cm)
K = 2-3/4" (7.0 cm)
L = 3" (7.6 cm)
A delight in freshness
13
C 16/CI 16
A delight in freshness
MOUNTING THE UPPER
VENTILATION
GRILLE
Figure 11
Screws
Grille
Installation Frame
Position the ventilation grille at the top of the
installation frame and attach it later with
countersunk screws (4 pieces, provided). Make
sure the grille fits flush laterally with the installation
frame.
IMPORTANT
If you are replacing the factory air vents with
an overlay, DO NOT restrict the air flow.The
air flow must be the same or greater than
the factory air vents of 31 square inches
(200 cm
2
).
14
C 16/CI 16
A delight in freshness
LEVELING THE REFRIGERATOR
1. Loosen the lower ventilation grille screws
(Fig. 12, 1).
The height can be adjusted in front by twisting
the leveling wheels (Fig. 12, 2).
2. Twist the adjusting bolt (Fig. 12, 3) to set up the
back of the refrigerator.
3. Rotate leveling until firmly in place against the
floor.
4. Align refrigerator with sides of kitchen cabinets
by adjusting leveling wheels and the supports.
5. Install the ventilation grille.
Figure 12
2
2
1
3
2
2
3
15
C 16/CI 16
A delight in freshness
BLOCKING FOR SAFETY
1. Secure the refrigerator in place so it does not tip
forward when the fully stocked door is opened.
2. Measure the distance from the floor to the upper
edge of the unit.
3. Locate and mark two wall studs against the wall
where the refrigerator will be located.The space
between the unit top and the bottom of the
brackets must not be more than 1/4" (0.635 cm).
4. Make sure the screws extend a minimum of 1"
(2.54 cm) into each of the wall studs.
5. Make sure the anti-tip brackets extend at least 3"
(7.62 cm) over the unit and are securely in place.
IMPORTANT
The anti-tip brackets can be installed in either
direction or closer together. Always position
the anti-tip brackets as wide apart as
possible, but make sure they are anchored to
two studs.
6. Using the front and rear levelers, raise the unit
until it makes contact with the brackets. Make
sure the front levelers are firmly on the floor to
prevent appliance from tipping forward.
IMPORTANT
If your unit is positioned in between the wall
studs, a board can be secured to the wall.
Make sure the board is secured to the studs
with screws that will penetrate into the studs a
minimum 1" (2.54 cm).The board should be a
minimum of 1" x 6" (2.54 cm x 15.24 cm) and
long enough to secure both ends to the wall
studs.
Figure 13
Wall Stud
Screws
Bracket
min 3"
16
C 16/CI 16
A delight in freshness
DOOR STOP ADJUSTMENT
Figure 15
1
2
Select between two opening angles: 130° and 90°.
Your appliance was delivered with a door opening
of 130°. If 90° opening angle is required, use this
procedure:
1. Close the refrigerator door.
2. Turn screw (1), provided, into bore (2).
Use the same procedure to set up the freezer door.
Figure 14
1
2
NOTES
17
C 16/CI 16
A delight in freshness
18
C 16/CI 16
A delight in freshness
REVERSING DOOR HINGES - CI 16
13. Mount the right installation frame (10) on the
other side. Discard the two other frames (11).
14. Mount the two enclosed frames (12) on the
right side. Do not forget the angle bracket
corner (13).
15. Lock the angle bracket (13) with the installation
frame.
16. Remove the door mounting from the refrigerator
and attach it on the other side (14).
17. Remove hinge sockets (15).
18. Remove door change frames (16).
19. Pull out shrouded-type panel (17) at the door
change frame at the handle side.
20. Remove screws (19).
21. Remove handle (18).
22. Remove the other door change frames (20) and
mount them on the opposite side.
23. Insert handle brackets (21) again into the slots
and attach handle.
24. Push shrouded-type panel (22) in the door
change frames.
25. Mount door change frames above and down
(23).
26. Insert hinge socket (24) into the frames.
27. Attach hinge socket (25) with screws to the
door.
28. Follow these instructions to change the other
door.
29. Insert spacers (26) for the upper door.
30. Attach center door fixture (27).
31. Place down lower door again on the lower door
mounting bracket.
32. Insert the metal pin (28) into the sleeve.
33. Position other door on the door mounting
center. Use other spacer (29) and attach door
with hinge bolt (30).
34. Mount the upper ventilation grille (Figure 11).
IMPORTANT
If the hinges and door handles are reversed,
you must obtain the Reverse Set.The
Reverse Set is not included with the unit.
Changing the door stop must be made by
two people to prevent personal injury and
damage to the doors.
1. Remove the upper ventilation grille if already
installed.
2. Remove the screw (1) at the door fixture.
Secure door to prevent personal injury
and to prevent the door from falling down.
3. Remove spacers (2).
The door can now be lifted and placed on the
floor.
4. Pull out the bearing pin (3) at the door fixture
center.
Secure door to prevent personal injury
and to prevent the door from falling down.
5. Lift the door and place it on the floor.
6. Remove the door fixture (4).
7. Loosen the screws at the door fixture.
8. Remove the screw (5) at the lower door fixture
and turn it into the other bore.
The door fixture down can be mounted again
on the other side (6).
9. Pull out plastic sleeve and assemble on the
opposite side of the bracket (7).
10. Remove both screws (8) at the back of the
installation frame.
11. Remove the 18 mounting screws (9) to
dismantle the installation frame.
12. Mount the installation frame.
CAUTION
!