*61442980G1C-22A*
COMPLIANCE
♦ ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wear anantistaticdischarge wrist
strapto preventdamagetoelectroniccomponents.Place
modulesinantistaticpackingmaterialwhentransportingor
storing.Whenworkingonmodules,alwaysplacethemonan
approvedantistaticmatthatiselectricallygrounded.
♦ TheXFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,andGR‐1089‐CORE.TheXFP
isintende dfordeploymentinCentralOfficetypefacilities,
EEEs, EECs, and locations wherethe NECapplies (for
example,CustomerPremises).TheXFPistobeins talledin
ADTRANproductsinRestricted
AccessLocationsonly,and
installedbytrainedservicepersonnel.
ThisdevicecomplieswithFCC47CFRPart15,ClassB.Operation
issubjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference.
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
Changesormodificationsnot
expresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
♦ PerGR‐1089‐CORE,theADTRA Nsy steminwhichtheSFPis
beingdeployedisdesigne dandintendedforinstallationas
partofaCommon Bondi ngNetwork(CBN).TheADTRAN
systeminwhichtheSFPisbeingdeployedisnotdesignednor
intendedforinstallationas partofan Isolated Bonding
Network(IBN).
♦ Per GR‐1089‐CORE Section 9, theXFP does nothavean
internalDCconnectionbet weenbatt eryreturnandframe
ground.TheXFPcanbeinstalledinaDC‐I(isolated)orDC‐C
(common)installation.Forinstallationswhereothe r cardsor
thehostsystemhaveinternalconnectionsbetweenbattery
returnandframe
ground,thesystemwouldbe intended for
deploymentonlyinaDC‐Cinstallation.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoare liable ea rthgroundtoensurethatthemetal
enclosureoftheXFPisproperlygroundedviathebackplane
connector.
TheXFPisaClass1LaserProductandcomplieswiththe Laser
SafetyrequirementsofFDA21CFR1040.10and1040.11,and
EN60825‐1and‐2.TheXFPisNRTLlistedandCBCertifiedtoall
applicableAmericanandEuropeansafetystandards.
Forcontinuedcompliancewiththeabovelasersafetystandards,
onlyapproved
Class1modulesfromourapprovedvendorlist,
locatedontheADTRANwebsite,shouldbeinstalledinADTRAN
products.
TheGigabi tEthernetport(s)areopticalandthereforearenot
classifiedasanytypeof portasdefi nedinAppe ndixBofGR‐
1089‐COREIssue4.
TheXFPisdesignedtomeetthefollowingenvironmentalclasses:
♦ ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ ETSIEN300019‐1‐2“Classificationofenvironmental
conditions,Transportation,”Class2.3
♦ ETSIEN300019‐1‐3“Classificationofenvironmental
conditions,Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.