Comfort DM02 Door Station Interface
Specifications
wDimensions: 108 x 88 mm
wMaximum Number of Door Station: 3
wPower Supply: 12V (supplied by Comfort)
Contents
The DM02 package consists of the following*:
wComfort DM02 Manual (this booklet)
w4 way cable for RS485 communications
w4 x 2 way removable terminal blocks
w3 x 3 way removable terminal blocks
*Subject to change without prior notice
Differences from DM01
DM02 is an improved RoHS-compatible version of DM01. It is able to
interface with more external intercoms than the DM01. DM02 will also
work with the new DP04 version of the Door Station
Settings
Connections
wJP5 - COM2/NO2/NC2: Terminals for Relay Contact for Open
Door Response
wJP4 - COM1/NO1/NC1: Terminals for Relay Contact for Open Gate
Response
wJP3 – BELL/GND/12V_OUT: Connector for Doorbell Input: 5 to 24
VAC or + 5 to 24 VDC voltage input initiates the doorbell. If
doorbell input is DC, shunt J1 header to position 1-2. If doorbell
input is voltage-free contact, shunt J1 to position 2-3.
wJP7 – MIC IN/SPK OUT: Connection to Intercom Outdoor Station.
wJP6 – MIC OUT/SPK IN: Connection to Comfort MIC/VOICE.
wJP2 - KA/KB: RS485 to Comfort
wJP1 - 12V_IN/COM: Voltage supply from Comfort.
wJP8/JP8A- Alternative connection for KA/KB/12V/GND (JP2 and
JP1) for short distances up to 1 meter from Comfort.
Jumper Settings
wJ1: Shunt J1 to positions 1-2 if the doorbell input (to BELL
terminal) is a DC signal of 5V to 24 VDC. Leave J1 open if the
Doorbell input is an AC signal 5 V to 24 VAC. Shunt J1 to positions
2-3 if the doorbell input is a voltage free contact. Default shunt.
2