Page 4 VSR-100 Manual
Basic VSR-100 Operations
1. Volume UP/Down may be controlled manually, by direct IR from the included remote
(Fig. 5.) and by wired IR to the IR IN port.
2. IR ported to the IR IN may be code from the handheld remote (included) or code
stored in Keypads, touch panels, or other learning remotes.
3. When the VSR-100 is first turned on, the volume is restored to the last setting before
the VSR-100 was turned Off.
Default Volume
Guards against high volume un-mutes.. To set or change the Default Volume, proceed as
follows:
1. Adjust the VSR-100 volume to the desired Default Volume.
2. Press and hold the MUTE button. While continuing to press the MUTE button, press
and hold the VOLUME DOWN button. (Note: Press the VOLUME DOWN button
very quickly pressing MUTE).
3. When the POWER SENSE LED (2) starts to blink, release both buttons. The Default
Volume level is set.
Note: The Default Volume will be activated whenever a manual or IR Volume command
is given. Also, if the pre-muted volume of the VSR-100 was higher than the Default
Volume level, and the VSR-100 is un-muted by any volume command, the VSR-100 will
be restored to the Default Volume level.
Fig. 5. VSR-1 Remote
Control
Override Volume
Provides a fixed volume level when the OVERRIDE port (13) is driven High, regardless of any other volume setting. It will also
un-mute a muted (Off) condition. This is useful when used in systems with Paging and/or Doorbell trigger control outputs. To
set or change the Override Volume, proceed as follows:
1. Adjust the VSR-100 volume to the desired Override Volume.
2. Press and hold the MUTE button. While continuing to press the MUTE button, press and hold the VOLUME UP button.
(Note: Press the VOLUME UP button very quickly after pressing MUTE).
3. When the POWER SENSE LED (2) starts to blink, release both buttons. The Override Volume level is now set.
SPECIFICATIONS
Power Handling .......................………….…...Output of Amplifiers Rated at 100 Watts RMS / Channel
Frequency Response...................................... 20Hz to 20KHz +/- 0.5dB @ 8 Ohms
Total Harmonic Distortion............................... < 1%
Impedance Settings.................................…… 1X / 2X / 4X
Minimum Speaker Load................................. 4 Ohms
Override Current Draw................................... 0.75 mA (Logic only)
Sense Current Draw....................................... 25 mA
Maximum Current Draw..............................… 40 mA
Operating Voltage......................................... 12 Volts DC
Sense Voltage.................................................9-12 Volts DC
Override Voltage.............................................9-12 Volts DC
Colors.............................................................White, Ivory, Almond, Black, and Brown
LIMITED 5-YEAR WARRANTY
SpeakerCraft warrants this product to be free of defects in materials or workmanship. This extends for five years from the date of purchase by the original
consumer. Any products returned to SpeakerCraft and found to be defective by SpeakerCraft within the warranty period will be repaired or replaced, at
SpeakerCraft’s option, at no charge. SpeakerCraft will not be responsible for the actual cost of installation or removal of the product, nor for any incidental or
consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply
to you. This warranty gives you specific legal rights. You may have additional legal rights that vary from state to state.
940 Columbia Avenue, Riverside, CA 92507
(800) 448-0976 Fax (951) 787-8747
www.speakercraft.com LIT90410
P/N: 9900699 REV:A
Volume
UP
Volume
DOWN
MUTE
UN-MUTE
Front View Side View PCB Bottom View
1
2
3456789 10 11 12
13
12
1415
OWNER’S MANUAL
VSR-100
IR Controlled Speaker-Level In-Wall Volume Control
The VSR-100 is a high powered 12-step speaker-level in-wall IR-controlled stereo volume control. It has Impedance
Match settings of 1X, 2X, and 4X and is designed for use with amplifiers up to 100 Watts of rated power output.
In addition to manual control of volume and mute, the VSR-100 features an IR receiver for remote control and also
allows IR data to be passed through for control of other system components. The VSR-100 also features IR input
porting so that external controllers can be hard wired for control of this device without using a “stick-on” IR emitter.
Included are the VSR-1 handheld Remote Control and the HDC1070 RJ45/CAT5 Interface Cable assembly.
The basic VSR-100 features and functionalities are as follows:
FEATURE DESCRIPTIONS (Refer to Fig. 1)
1. IR Receiver Sensor
2. Activity LED - Flashes when activated with IR commands and default level settings.
3. Volume Level LEDs – Shows 11 volume level settings at a glance.
4. Volume UP/Down Buttons – For manual volume adjustments.
5. Mute Button – For manual sound muting. When muted, Volume Level LEDs go off.
6. Decora Insert Plate – Included.
7. Metal Mounting Plate – Permits mounting to standard J-Boxes.
8. IR/Controller PCB
9. Level Switching Relays – Controlled relays select 11 volume levels plus Off.
10. Autoformers – Permit audio level settings and impedance matching to speakers.
11. Removable Screw-Down Speaker Connector – Connect these to system speakers.
12. Impedance Matching Jumpers – Permits proper impedance matching of multiple speaker pairs
to a single pair of amplifier channels. Refer to “IMPEDANCE MATCHING” below, for settings.
13. RJ45 IR/Control Port – Port for IR I/O, Override and Sense signals.
14. Removable Screw-Down Amplifier Connector – Connect these to system amplifier terminals.
15. Front Cover Plate – Not included.
Fig. 1. The VSR-100
SPEAKERCRAFT
DATE:11-15-05 • LIT90410 • MATERIAL: 70 LB GLOSS WHITE COATED PAPER •
INK: BLACK • DESCRIPTION: MANUAL FOR VSR-100 ASM90410 • FOLDING: 1 VERTICAL, 1 HORIZONTAL, 1 VERTI-
CAL, FINISH WITH PRODUCT NAME SHOWING • SIZE: 7X10 • SCALE: 1:1 • P/N: 9900699 • REVISION: A • ECN: 1498
VSR-100 manual.indd, Spread 1 of 2 - Pages (4, 1) 11/14/05 3:04 PM