Atlantis A08-OLS60 Quick start guide

Category
Bar code readers
Type
Quick start guide

This manual is also suitable for

Atlantis A08-OLS60-H is an omnidirectional single-line laser scanner that can be programmed to read various barcode symbologies, including Codabar, Code39, Code32, ISSN/ISBN, Chinese post code, Code93, Code128, MSI, ITF 2 of 5, UPC-A/UPC-E/EAN-8/EAN13, GS1 DataBar Omnidirectional, GS1 DataBar Limited, and GS1 DataBar Expanded. It can be interfaced with a computer via PC/AT, RS-232C, USB, or keyboard wedge, and can be configured to emulate a US keyboard, international keyboard (ALT method), IBM AT, Italian, German, Spanish, or French keyboard.

Atlantis A08-OLS60-H is an omnidirectional single-line laser scanner that can be programmed to read various barcode symbologies, including Codabar, Code39, Code32, ISSN/ISBN, Chinese post code, Code93, Code128, MSI, ITF 2 of 5, UPC-A/UPC-E/EAN-8/EAN13, GS1 DataBar Omnidirectional, GS1 DataBar Limited, and GS1 DataBar Expanded. It can be interfaced with a computer via PC/AT, RS-232C, USB, or keyboard wedge, and can be configured to emulate a US keyboard, international keyboard (ALT method), IBM AT, Italian, German, Spanish, or French keyboard.

Enter/Exit programming
All program setup must start and
end with reading this barcode to
save any changes.
Interface Selection
PC/AT
RS-232C
USB
Keyboard Type Selection
US Keyboard
International Keyboard
(ALT Method)
IBM AT
Italian
German
Spanish
French
Symbologies Setting
Codabar enable
Code39 enable
Code32 enable
ISSN/ISBN enable
Chinese post code enable
Code93 enable
Code128 enable
MSI enable
ITF 2 of 5 enable
UPC-A/UPC-E/EAN-8/EAN13 enable
GS1 DataBar Omnidirectional enable
GS1 DataBar Limited enable
GS1 DataBar Expanded enable
Codabar disable
Code39 disable
Code32 disable
ISSN/ISBN disable
Chinese post code disable
Code93 disable
Code128 disable
MSI disable
ITF 2 of 5 disable
UPC-A/UPC-E/EAN-8/EAN13 disable
GS1 DataBar Omnidirectional sable di
GS1 DataBar Limited di sable
GS1 DataBar Expanded disable
Omnidirectional Scanner
Quick Start Guide
Il manuale di configurazione completa può essere scaricato dal sito
www.atlantis-land.com
P/N: 593-36170E-000
Introduction
The Quick Guide contains only part of programming
barcode labels that are often used, and is for
omnidirectional scanners with single-line scan mode
only. (A08-OLS60, A08-OLS60-H)
Please see the following instructions to program your
scanner.
1. Locate the single-line switch button on your
scanner. It can be used to emit a single line
pattern to scan the labels contained in this guide.
2. Press the single-line switch button to scan the
Enter/Exit programming label.
3. Scan all necessary labels to configure the scanner
for your application.
4. Scan the Enter/Exit programming label again to
save the changes.
The scanner must be properly powered before
programming. During the programming mode, the laser
scanner will acknowledge a good and valid reading with
a short beep. It will give long beeps for either an invalid
or bad reading.
Detailed instructions and safety notices please refer to
your User’s Manual.
Important Notice
No warranty of any kind is made in regard to this
material, including, but not limited to, implied
warranties of merchantability or fitness for any
particular purpose.
Laser Safety
The laser scanner complies with CDRH Class IIa and
the IEC 60825-1: Class 2. The scanner contains
internally a Visible Laser Diode (VLD) whose emissions
do not exceed the maximum limits as set forth in the
above regulations. Class lla and Class 2 products are
not considered to be hazardous to human.
Copyright © 2011. All rights reserved.
Enter/Exit programming
All program setup must start and
end with reading this barcode to
save any changes.
Reset
The reading of the "RESET” label
turns all the parameters back to
default values.
Abort
The reading of the "ABORT" label
discards all the parameters read
prior to the "End of configuration".
Version
The reading of the “SHOW
VERSION” label will show the
firmware version.
USB Mode
The USB mode is effectively a keyboard emulator works with
hosts that are USB-compatible operating systems and have USB
ports. USB compatible operating systems are Windows 98,
Windows NT 5.0 and Mac OS 8 and later, no additional software
is needed since the USB driver support is built into this operating
system.
Message Terminator
None
H Tab
Enter
Keyboard Wedge Mode
Message Terminator
None
Enter
Hor. Tab
Execute
RS-232 Mode
The factory default communications are: 9600 baud, 8 data bits,
mark parity, 1 stop bit, and CR/LF terminator message.
Baud Rate
19200
4800
1200
9600
2400
600
Data Bit
7
8
Stop Bit
1
2
Parity
Even
Mark
None
Odd
Space
Message Terminator
None
CR
H Tab
EOT
CR/LF
LF
STX/ETX
Single-line switch button
  • Page 1 1
  • Page 2 2

Atlantis A08-OLS60 Quick start guide

Category
Bar code readers
Type
Quick start guide
This manual is also suitable for

Atlantis A08-OLS60-H is an omnidirectional single-line laser scanner that can be programmed to read various barcode symbologies, including Codabar, Code39, Code32, ISSN/ISBN, Chinese post code, Code93, Code128, MSI, ITF 2 of 5, UPC-A/UPC-E/EAN-8/EAN13, GS1 DataBar Omnidirectional, GS1 DataBar Limited, and GS1 DataBar Expanded. It can be interfaced with a computer via PC/AT, RS-232C, USB, or keyboard wedge, and can be configured to emulate a US keyboard, international keyboard (ALT method), IBM AT, Italian, German, Spanish, or French keyboard.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI