The Great Outdoors 1496-252-PL User manual

Type
User manual

The Great Outdoors 1496-252-PL lantern is great for both indoor and outdoor use. The fixture is ETL Listed for Wet Location applications, so you can use it in areas that are exposed to moisture or rain. It is also rated for a minimum start temperature of 0 degrees Fahrenheit, so it can be used in cold climates. The lantern comes with a CFL bulb, but you can replace it with a UL and CUL Listed Self-Ballast Fluorescent Lamp if you want to use a different type of bulb. The ballast in the lantern can be replaced by a qualified electrician without cutting any wires or damaging the fixture.

The Great Outdoors 1496-252-PL lantern is great for both indoor and outdoor use. The fixture is ETL Listed for Wet Location applications, so you can use it in areas that are exposed to moisture or rain. It is also rated for a minimum start temperature of 0 degrees Fahrenheit, so it can be used in cold climates. The lantern comes with a CFL bulb, but you can replace it with a UL and CUL Listed Self-Ballast Fluorescent Lamp if you want to use a different type of bulb. The ballast in the lantern can be replaced by a qualified electrician without cutting any wires or damaging the fixture.

INSTALLATION INSTRUCTIONS
Item#1496-PL (New. 09/27/2009)
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUI T BRE AKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
Fig. 1
Fig. 2
PREPARATION (Fig.1)
1. Shut off power at the circuit breaker and remove old fixture
including mounting hardware.
2. Carefully unpack your new fixture and lay out all the parts
on a clear area. Take care not to misplace any small part
necessary for installation.
CONNECTING THE WIRES (Fig.2)
3. Pull black, white and ground wires out of Post.
4. Next, connect electrical wires while supporting the lantern.
If your outlet has a ground wire (green or bare copper),
connect the fixture ground wire to it. If not, consult your
electrician for proper grounding. After wires are connected,
tuck them carefully inside the post. Align the lantern with
post and secure with Sheet Screws (G). (Fig.1&2)
COMPLETING THE INSTALLATION
5. Insert the Glass Panels (D) into Fixture Body (F) and
secure them using clips on the bottom of fixture body.
6. For installing bulbs or replacing bulbs at a later date,
unscrew the Finial (A) and remove the Top Plate (B).
7. Install the CFL bulb (E) (included) into socket in
accordance with the fixtures specification. (DO NOT
EXCEED THE SPECIFIED WATTAGE!) (NE PAS
DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).
8. After the installation, align the center hole of the Top Plate
with the center hole on the top of fixture body and secure
with Finial (A).
9. The ballast in each of these models can be replaced by a
qualified electrician without cutting of wires and without
damage to the housing, trim, decorative elements or
carpentry to which the fixture is attached. The ballast and
lamp are combined, to replace or install, twist pins into
socket as shown on Fig 3.
10. This fixture is rated for a minimum start temperature of
0 degrees Fahrenheit (-17 degree Celsius).
11. This fixture is ETL Listed for Wet Location applications.
Your installation is now complete. Return power to the
junction box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation
purposes only. It may or may not be identical to the
fixture purchased.
LA-1467E
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
HOUSE
WIRES
White
(Neutral)
FIXTURE
WIRES
Green or
Bare
Copper
(Ground)
HOUSE
WIRES
Green
(Ground)
Fig.3
A
B
D
E
F
G
C
  • Page 1 1

The Great Outdoors 1496-252-PL User manual

Type
User manual

The Great Outdoors 1496-252-PL lantern is great for both indoor and outdoor use. The fixture is ETL Listed for Wet Location applications, so you can use it in areas that are exposed to moisture or rain. It is also rated for a minimum start temperature of 0 degrees Fahrenheit, so it can be used in cold climates. The lantern comes with a CFL bulb, but you can replace it with a UL and CUL Listed Self-Ballast Fluorescent Lamp if you want to use a different type of bulb. The ballast in the lantern can be replaced by a qualified electrician without cutting any wires or damaging the fixture.