Transmitter GK350 Owner's manual

Type
Owner's manual

This manual is also suitable for

Electric Strike Installation Instruction
GK300 Series
Specification
Operating Voltage
Voltage Tolerance
Current Draw
Operating Temperature
Humidity
Optional Bracket
12 VDC,24 VDC,12/24VDC
LP-025, LP-050
250 mA/12 VDC
150 mA/24 VDC
-10°C~+45°C
GK301M
0~95%
LP-050
50mm(L)
LP-025
25mm(L)
±15%
GK350 GK350
GK301 , GK301M
GK300 , GK300M
GK310 , GK310M GK311 , GK311M
GK350
GK300
GK300M
GK301
GK310
GK310M
GK311
GK311M
GK302
GK302M
GK312
GK312M
GK302 , GK302M
GK312 , GK312M
Hollow Metal
Frames
Wooden
Frames
Bond Sensor
Output
Installation Application
Locksets
Spring latch
Latch-bolt lock
Night Latch
Surface Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Mortise Mount
Gk300 series electric strikes are designed for spring latch or lockset (e.g. cylindrical locks). The latch bolt lock comprises a latch bolt and a
Nib . The GK300 electric strike can easily be changed between fail-safe and fail-secure modes. (versions)
Hollow Metal Frames Wooden Frames Hollow Metal Frames Wooder Frames
g
n
i
w
s
n
I
g
n
i
w
s
n
I
g
n
i
w
s
n
I
g
n
i
w
s
n
I
Electric Strike Mechanical lock set (excluded)
What is a Nib?
When the door is closed , the Nib makes
the latch a dead bolt. The latch bolt locks
into the strike keeper of the door frame to
make sure that it is closed.
Nib
Latch bolt
Faceplate
Latch opening
Keeper
Base
Cable
How to change Version?
Field selectable by changing position of screws
Fail-Secure
(Power to Open) Fail-Safe
(Power to Lock)
Optional Brackets
Lip extension brackets for wide jamb
(Surface mount installation sketch GK350)
Copyright © Gianni Industries, Inc. All rights reserved.
P-MU-GK Ver. N Publish:2011.03.22
Installation Instruction
Measure the latch position Mark the latch position Mount the supplied installation template
and align to the marked line
Drill and cut the hole according to the
template supplied
Tighten the fixing plug Connect the power and test the unit
Caution:
Proper gap must be reserved between the strike keeper and latch bolt to prevent failure of solenoid valve.
Single Voltage (12V or 24V)
Blue: N.O.
Green: COM.
Yellow: N.C.
White: 12 VDC Red: 24 VDC
White: 12 VDC Red: 24 VDC
(Polarity Free) Control Device
N.C. contact or Access Relay for “Fail-safe” setting
N.O. contact or Access Relay for “Fail-secure” setting
Bond Sensor Output: GK300M , GK301M , GK302M,GK310M,GK311M,GK312M
Reed Switch rated: 3A/125VAC,1.5A/250VAC
Using crimper or pliers and pressing the header
of connector down to even position
-
Power
supply
+
+
-
N.O. dry contact output:
opened status
N.C. dry contact output:
When the micro switch is
pressed by latch bolt
(2) (3)
(4) (5)
(1)
Connecting Diagram
Butt Splice (IDC) Connector
(6)
Copyright © Gianni Industries, Inc. All rights reserved.
P-MU-GK Ver. N Publish:2011.03.22
Dual Voltage (12V/24V)