Aeg-Electrolux PX1200UOV User manual

Type
User manual

This manual is also suitable for

Istruzioni per l’uso e l’installazione
Piani di cottura
Hobs
Kochfelder
Tables de cuisson
Placas de cocción
Instructions for use and installation
PX 1200 UOV
IT
EN
Bedienungs- und
Installationsanleitung
DE
Mode d’emploi et instructions
de montage
FR
Manual de instrucciones
de uso e instalación
ES
electrolux 15
Electrolux. Thinking of you.
Thank you for choosing an Electrolux appliance offering performance characteristics,
quality and reliability designed to make life easier, safer and more comfortable for you.
We have always been committed to manufacturing, using cutting-edge technology,
in respect for the environment and always in full compliance with the applicable
regulations.
Read this handbook carefully, as it contains important information on the correct and
safe use and maintenance of the appliance.
Electrolux
and the WWF
together for
sustainable
growth
Contents
For your safety 16
Instructions for use 17
Cleaning and maintenance 19
Periodical maintenance 19
Technical characteristics 19
Installer instructions 21
Gas connection 21
Electrical connection 22
Conversion to other types of gas 23
Fitting in modular cabinets 24
Fitting possibilities 25
Assistance and replacements 26
Warranty terms 26
16 electrolux
For your safety
This new appliance is easy to use.
Nevertheless, make sure to read this
handbook carefully before installing and
using it for the first time. In this way you can
obtain best results, avoid incorrect
operations, use the appliance in complete
safety and respect the environment.
This instruction handbook must be kept
with the appliance for any future
consultation. If the appliance is sold or
given to another person, make sure the
handbook goes with it, so that the new user
has the relevant instructions for use.
Installation
Appliance installation and electrical
connection must only be carried out
by QUALIFIED PERSONNEL. Before
carrying out any operation, make sure
the appliance is DISCONNECTED from
the power supply.
Make sure the air can circulate freely
around the appliance. Poor ventilation
creates a lack of oxygen.
Make sure the appliance is fed with the
type of gas specified on the special sticker
located near the gas connection pipe.
This appliance is not connected to a
fume extraction device. It must be
installed and connected in compliance
with the current applicable regulations.
Particular attention must be paid to the
applicable provisions regarding
ventilation.
The use of a gas cooking appliance
produces heat and humidity in the
room where it is installed. Ensure
good ventilation in the room by
keeping air inlets open and
efficient, or install an extractor
hood with exhaust flue.
In case of intensive and prolonged
appliance use, room ventilation
must be made more efficient by
opening a window or increasing
the speed of the electric exhaust
fan, if present.
After unpacking the appliance, make sure
it is not damaged and that the power
cable is in perfect condition. Otherwise,
contact the dealer before using the
appliance.
The Manufacturer declines any
liability if the accident-prevention
regulations are not respected.
Safety
This appliance must only be used by
adults. Make sure children do not
play with the appliance or touch
the controls.
This appliance must not be used by
persons (including children) with reduced
physical, sensory or mental abilities, or
without experience or knowledge of it,
unless supervised or instructed in its
correct use by a person responsible.
The exposed parts of this appliance
become hot during cooking and remain
hot for some time even after it is turned
off. Keep children away until it has
cooled.
During use
This product is designed for non-
professional domestic use, for cooking
food. Do not use it for any other
purpose.
Any attempt to modify the characteristics
of this product is hazardous.
Keep the appliance clean. Food
residuals can create the risk of fire.
Do not use steam or steam devices to
clean the appliance.
After using the appliance, make sure all
the controls are in the “CLOSED” or
OFF” position.
When using a power socket near this
appliance, make sure the cords of any
electrical appliances being used do not
touch it and are far enough away from
its hot parts.
electrolux 17
Technical assistance
In case of a fault, never attempt to
repair the appliance on your own.
Repairs carried out by unqualified
persons can cause damage and
accidents. Firstly, consult this handbook.
If you do not find the necessary
information, contact the nearest
After-Sales Service Centre.
Assistance for this appliance must be
carried out by an authorised After-Sales
Service Centre. Always demand the use
of original replacement parts.
Advice for safeguarding the
environment
All the materials used are environmentally
friendly and recyclable. Please make your
contribution to safeguarding the
environment by using the appropriate
differentiated waste collection channels.
Before scrapping the appliance,
cut off the power cord and make it
unusable.
The symbol
on the product or on the
packing indicates that the product should
not be treated as normal household waste
but must be taken to an appropriate
collection point for the recycling of
electrical and electronic equipment.
Correct disposal of this appliance will
help prevent possible negative
consequences for the environment and
the health of people. For more detailed
information about the recycling of this
product, contact your local council office
or waste disposal service, or the shop
where you purchased it.
Instructions for use
Before using the appliance,
remove all the packing
materials, including the
advertising labels and any
protective film.
Hob control knobs
The knobs for the gas rings are located on
the side of the top. The symbols on the
control zone have the following meaning:
no gas
max. gas
min. gas
lighting incorporated in the cock
Lighting the rings
To obtain the flame more easily,
light the ring before placing a
pot or pan on the grate.
Press the knob corresponding to the ring and
turn it anticlockwise to the “max.” symbol.
The lighting symbol (
) is also located in
this position. The flame will light automati-
cally.
Do not operate the igniter for
more than 15 seconds. If the
burner is not lit after 15 seconds,
stop operating the igniter and
wait at least 1 minute before try-
ing to light it again.
After lighting the flame, keep the knob
pressed for about 5 seconds. This time is
necessary for heating the “thermocouple”
and deactivating the safety valve, which
would otherwise stop the delivery of gas.
18 electrolux
Then make sure the flame is even and turn
the knob to the required setting.
If the flame does not light after several
attempts, make sure the “burner cap” and
“flame spreader” are in the correct position.
1
2
3
4
1
2
4
3
1 Burner cap
2 Flame spreader
3 Igniter
4 Thermocouple
1 Burner cap flame spreader assembly
2 Burner cap flame spreader assembly
3 Igniter
4 Thermocouple
To turn off the flame, turn the knob clockwise
to the symbol
.
Manual lighting (in case of a
power failure): bring a flame to the
ring, press the knob and turn it
anticlockwise to the “max.” symbol.
Always lower the flame or turn it
off before removing pots and pans
from the rings.
If the burner accidentally goes
out, close the control knob and
wait at least 1 minute before
relighting it.
For correct hob use
To ensure lower gas consumption and
better efficiency, only use flat bottom
pots and pans of size suitable for the
rings, as given in the table at the bottom
of the page. Also, as soon as a liquid
starts to boil, lower the flame enough to
keep it on the boil.
Carefully watch over your food during
cooking with fats or oils, because
these substances can catch fire when
very hot.
Do not use aluminium foil to
protect the top during use.
Make sure pots and pans do not
protrude over the edges of the top
and that they are placed centrally on
the rings in order to obtain lower gas
consumption.
Always lower the flame or turn it off
before removing pots and pans from
the rings.
Do not place unstable or
deformed pots and pans on the
rings: they could tip over or
spill their contents, causing
accidents.
Pots must not occupy any part
of the control zone.
electrolux 19
min. max.
Burner
diameter diameter
Triple crown 180 mm 260 mm
Large (rapid) 160 mm 260 mm
Medium (semirapid ) 120 mm 220 mm
Small (auxiliary) 80 mm 160 mm
Cleaning and maintenance
Before carrying out any
operation, disconnect the
appliance from the power
supply and allow it to cool.
General cleaning
Clean the hob top regularly with a soft
cloth soaked in lukewarm water and a
little liquid detergent. Do not use the
following products:
- household detergents or bleaches;
- soapy scouring pads unsuitable for
non-stick pots and pans;
- steel wool;
- bath or sink stain removers.
If the hob is very dirty, use specific
products available on the market.
Do not leave acid or alkaline substances
(e.g. vinegar, salt, lemon juice, etc.) on
the hob.
If you notice any breakage or
cracks on the glass top,
immediately disconnect the
appliance to avoid risk of
electric shocks, contact an
After-Sales Service Centre and
do not use the appliance until
it is repaired.
Hob grates
The hobs have cast iron grates.
The grates can be removed from to enable
better cleaning.
Keep the cast iron grates in their seats,
to avoid scratching or damaging the
top.
The grates cannot be placed in a
dishwasher; after washing by
hand, make sure to correctly refit
them.
Electric igniter
Automatic lighting of the rings is ensured
by a ceramic igniter containing a metal
electrode. Carefully clean these parts of the
top periodically. Also, to avoid difficult
lighting make sure the flame spreader holes
are not clogged.
Periodical maintenance
Have the condition and efficiency of the gas
pipe and the pressure regulator (if present)
periodically checked.
In case of any anomalies, have the faulty
part replaced (and not repaired).
Technical characteristics
Gas burner power
Triple crown burner 4.0 kW
Rapid burner 2.9 kW
Semirapid burner 1.9 kW
Auxiliary burner 1.0 kW
Category II2H3+
Appliance setting natural gas
G20 (2H)
20 mbar
Gas inlet connection G 1/2"
Power supply voltage 220-240 V
~ 50-60 Hz
Appliance class 3
20 electrolux
Hob dimensions
Width 1175 mm
Depth 350 mm
Dimensions of opening for fitting
Width 1145 mm
Depth 320 mm
Bypass diameters
Burner Ø Cock
bypass in
hundredths
Auxiliary 33
Semirapid 33
Rapid 45
Triple crown 65
Burner specifications
NOMINAL REDUCED NOMINAL
TYPE OF HEATING HEATING HEATING CAPACITY
BURNER CAPACITY CAPACITY
NATURAL GAS LIQUEFIED GAS
(Natural gas) (Butane/Propane)
kW kW 20 mbar 28-30/37 mbar
Nozzle Nozzle g/h
marking m
3
/h marking G30 G31
100/mm 100/mm
Auxiliary
burner 1.0 0.52 7 0 0.095 5 0 73 71
Semirapid
burner 1.9 0.60 9 6 0.181 71 138 136
Rapid Natural Gas:
burner 2.9 1.10 119 0.276 86 204 200
LPG: 2.8
Triple crown
burner 4.0 1.80 146 0.381 98 291 286
electrolux 21
Installer instructions
ATTENTION: This appliance can
only be installed and used in
permanently ventilated places
in conformity with UNI 7129
and UNI 7131.
The manufacturer declines any
liability for damage due to
installation not complying with
the current standards or failure
to respect the accident-
prevention regulations.
Appliance installation and connection
to the power supply must only be carried
out by QUALIFIED PERSONNEL.
Before carrying out any operation, make
sure the appliance is DISCONNECTED
from the power supply.
Installation room
For correct operation of the gas appliance,
the air necessary for gas combustion must
be able to flow naturally in the room.
(The installer must comply with the current
UNI-CIG 7129 - 7131 standards).
The air must flow into the room through
openings made in the external walls.
These openings must have a free open
section of at least 100 cm
2
if the appliance
is equipped with a safety device or 200 cm
2
if the appliance does not have a safety
device.
This opening must be located near the floor,
preferably on the opposite side to fume
extraction, and be made in such a way that
it is not obstructed from the inside or
outside. If the opening cannot be made in
the room where the appliance is installed,
the necessary air can come from an
adjacent room, provided:
it is not a bedroom or a dangerous
environment;
it is not in low pressure;
the ventilation between the room where
the appliance is installed and the
adjacent room is ensured by means of
permanent openings (UNI-CIG 7129).
Fume exhaust
Gas cooking appliances must exhaust the
fumes through hoods directly connected to
flues or directly to the outside.
If a hood cannot be installed, it is necessary
to use an electric exhaust fan fitted on the
external wall or the window of the room,
provided conditions exist so that the opening
for ventilation can be increased in proportion
to the fan capacity (UNI-CIG 7129).
This electric exhaust fan must be able to
guarantee an hourly air change for a kitchen,
equal to 3-5 times its volume.
Gas connection
The gas connection must be carried out in
compliance with UNI-CIG 7129 - 7131
standards. The appliances leave the factory
tested and adjusted for the type of gas
specified on the label located in the bottom
protection, near the gas connection pipe.
Make sure the type of gas used is the same
as that specified on the label.
Otherwise, proceed according to the
instructions given in the section “Conversion
to other types of gas”.
To ensure maximum efficiency and
minimum consumption, make sure the gas
supply pressure respects the values given
in the “Burner specifications” table.
If the pressure of the gas used is different
(or variable) with respect to that provided
for, a suitable pressure regulator for the gas
(NOT LPG) complying with Standard UNI
EN 88 must be installed on the inlet piping.
The use of pressure regulators for liquefied
gases (LPG) is allowed provided they
comply with Standard UNI EN 12864.
The union is fitted on the end part of the
train, with a G 1/2" threaded nut, interposing
the seal between the components as shown
in the figure. Screw the parts without forcing,
turn the union in the required direction, then
tighten everything.
22 electrolux
Connection
Make the connection to the gas system using
a rigid metal pipe and fittings complying
with Standard UNI-CIG 7129, or with a s/
steel flexible tube complying with Standard
UNI-CIG 9891, limited to those not longer
than 2 m. When using flexible metal tubes,
make sure they are not in contact with
movable parts or squashed. Pay the same
attention also when an oven and hob
combination is provided for.
The gas inlet union for the appliances is 1/
2" cylindrical male thread.
Make the connection, avoiding any kind of
stress on the appliance.
Important
After installation, always check the
perfect tightness of all unions using a
soapy solution. Never carry out
this check with a flame.
Electrical connection
The appliance is arranged to operate on a
230V single-phase power supply. Connection
must be made in compliance with current
standards and regulations.
Before carrying out the connection, make
sure:
the limiter valve and the electrical system
can take the appliance load (see serial
no. plate);
1 Train end with nut
2 Seal
3 Adjustable union
4 Copper pipe
5 Flexible steel tube
1
2
3
2
5
4
the supply system is equipped with an
efficient earth connection in compliance
with the current standards;
the socket or omnipolar switch used are
easily accessible with the appliance
installed.
Fit the cable with a plug suitable for the
load and connect it to an adequate safety
socket.
To connect directly to the mains, a suitable
omnipolar switch with contact gap of at
least 3 mm and complying with current
standards must be installed between the
appliance and the power mains.
The yellow/green earth wire must not be
interrupted by the switch.
The brown phase wire (coming from
terminal “L” on the terminal block) must
always be connected to the power supply
phase.
In any case the power cable must be
positioned in such a way that no part of it
reaches a temperature above 90 °C.
An example of an optimum path is shown
in the figure. The cable is guided by means
of clamps fixed to the side of the cabinet, in
order to avoid any contact with the
equipment beneath the hob.
The installation or replacement of any
electrical component must be carried out
by a Service Centre technician or qualified
personnel.
Replacing the power cable
When replacing the power cable only use
H05V2V2-F T90 type cables suitable for the
load and operating temperature. The yellow/
green earth wire must be approx. 2 cm longer
than the phase and neutral wires.
1 Neutral
2 Earth (Yellow/Green)
1
2
electrolux 23
After connection, test the heating elements
by making them work for about 3 minutes.
To open the terminal block cover and access
the connection terminals, proceed as
follows:
undo the cover fixing screw;
insert the tip of a screwdriver in the
protrusions located on the inner side of
the terminal block;
press lightly and prise upwards.
The use of pressure regulators for liquefied
gases (LPG) is allowed provided they
comply with Standard UNI EN 12864.
Minimum flame adjustment
To adjust the minimum flame, proceed as
follows.
1. Light the ring as previously described.
2. Turn the cock to the min. flame position.
3. Extract the knobs.
4. Operate on the bypass pin.
1 Min. flame adjustment bypass pin
The power cable must only be
replaced by the After-Sales
Service or by similarly qualified
personnel.
Conversion to other types of gas
Replacing nozzles
1. Remove the grates.
2. Remove the burner caps and flame
spreaders from the rings.
3. Using a socket wrench, unscrew and
remove the nozzles, replacing them with
those corresponding to the type of gas
used (see “Burner specifications” table
on page 20).
4. Refit the parts by carrying out the above
operations in reverse order.
5. Then replace the label (located near the
gas connection) with the one for the new
type of gas. The latter is included in the
bag of injectors supplied.
If the pressure of the gas used is different (or
variable) with respect to that provided for, a
suitable pressure regulator for ducted gas
(NOT LPG) complying with Standard UNI
EN 88 must be installed on the inlet piping.
1
1
When converting from natural gas to
LPG, screw down the bypass pin
clockwise.
When converting from LPG to natural gas,
unscrew the bypass pin approx. 1/4 turn.
In any case, the result must be a small
and even flame on all the burner crown.
5. Lastly, check that the burner does not
go out when quickly turning the cock
from max. to min.
The above adjustment operations can be
easily performed, whatever the position or
fixing of the hob on the kitchen unit.
24 electrolux
1
1175
350
2
3
4
Fitting in modular cabinets
1 Rapid burner
2 Semirapid burner
3 Triple crown burner
4 Auxiliary burner
These hobs are arranged for fitting in
modular kitchen units having a depth of
between 550 and 600 mm and suitable
characteristics.
The hob dimensions are given in the
“Technical Data” section.
Fitting and fixing to the cabinet
The hob can be fitted in a cabinet having an
opening of the size illustrated. The opening
must be at least 55 mm from the rear wall.
Any right or left side wall higher than the hob
must be at least 100 mm from the recess in
the top.
Before fitting the hob in the recess, apply the
special adhesive seal. This seal must be fixed
evenly without breaks or overlapping, in order
to prevent liquid from entering under the hob.
550 MIN.
650 MIN.
593
60
5
5
0
M
IN
.
3
2
0
5
5
1145
5
6
0
÷
5
7
0
2
4
0
1
4
0
electrolux 25
The hob must be fixed to the cabinet as follows:
1) Apply the sealing strip 8 mm from the
opening.
8
Fitting possibilities
On base cabinet with door
Adequate arrangements must be ensured
in the construction of the cabinet, to prevent
possible contact with the overheated
housing of the hob during operation. The
recommended solution for avoiding this
problem is shown in the figure below.
The panel under the hob must be easily
removed in order to secure and release of
the hob in case of technical assistance.
On base cabinet with oven
The compartment must have the dimensions
given in the figure on the previous page and
must have supports to allow efficient
ventilation.
To avoid excessive overheating, it is advisable
to carry out installation as shown in the figures
below.
1 Sealant
60
60
1
2
min. 20
1 Removable cabinet panel
2 Possible space useful for connections
2) Arrange the hob in the recess, making
sure it is centred.
3) Fix the hob to the cabinet with the special
stays supplied.
1
1
26 electrolux
The electrical connection of the hob and that
of the oven must be carried out separately
for electrical reasons and to facilitate
frontal oven removal.
Wall units or extractor hoods must be at
least 650 mm from the hob.
In case of 600 mm wide hoods, as well as
respecting the height, wall units next to the hood
must be positioned at a height of at least
550 mm from the top, to enable possible fitting
of the cover and its correct use.
Assistance and replacement parts
Before leaving the factory this appliance
was tested and adjusted by expert and
specialised personnel in order to ensure best
operation. Any repairs or adjustments
subsequently required must be carried out
with maximum care and attention.
Therefore always contact the Dealer who sold
the product or our nearest Service Centre,
specifying the type of problem, appliance
model (Mod.), product number (Prod. No.)
and serial number (Ser. No.). These details
are given on the label in the bag of injectors
supplied.
Original replacements, certified by the product
manufacturer, and identified by this mark, are
only available at our Service Centres and
Authorised Replacement
Parts Shops.
Warranty terms
Your new appliance is covered by warranty.
The warranty terms are given in full in the
TOP SERVICE” booklet included inside the
appliance.
Carefully keep the receipt or waybill
together with the “TOP SERVICE” booklet,
as documentation of the purchase (and
purchase date) of your appliance.
Show these documents to the appointed
personnel in case of After-Sales Service
assistance. Otherwise the After-Sales Service
will be obliged to charge you for any repairs.
Through its many authorised Centres, the
After-Sales Service provides assistance
in Italy for the leading brands of electrical
appliances. In case of need, you can find the
nearest Centre by consulting the “TOP
SERVICE” booklet or the “Electrolux
Service” in the Yellow
Pages under Electrical
Appliances/Repair.
58 electrolux
Características técnicas
Potencia de los quemadores de gas
Quemador con triple corona 4,0 kW
Quemador rápido 2,9 kW
Quemador semirrápido 9,1 kW
Quemador auxiliar 1,0 kW
Categoría II2H3+
Ajuste aparato gas metano
G20 (2H)
20 mbar
Empalme de entrada del gas G 1/2
Tensión de alimentación 220-240 V
50-60 Hz
Equipo de clase 3
Dimensiones de la placa de cocción
Ancho 1175 mm
Profundidad 350 mm
Medidas del aparato para encastre
Ancho 1145 mm
Profundidad 320 mm
Diámetros del By-pass
Quemador Ø By-pass
de la llave
en centésimas
Auxiliar 33
Semirrápido 33
Rápido 45
Triple corona 65
Características de los quemadores
POTENCIA POTENCIA POTENCIA
TIPO DE TÉRMICA TÉRMICA TÉRMICA NOMINAL
QUEMADOR NOMINAL REDUCIDA
GAS NATURAL GAS LÍQUIDO
(Metano) (Butano/Propano)
kW kW 20 mbares 28-30/37 mbares
Marc. Marc. g/h
inyect. m
3
/h inyect. G30 G31
100/mm 100/mm
Quemador
auxiliar 1,0 0,52 70 0,095 50 73 71
Quemador
semirrápido 1,9 0,60 9 6 0,181 71 138 136
Quemador G.Natural:
rápido 2,9 1,10 119 0,276 86 204 200
G.P.L.: 2,8
Quemador
triple corona 4,0 1,80 146 0,381 9 8 291 286
39712-6901 04/09 R.A
www.electrolux.com/shop
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65

Aeg-Electrolux PX1200UOV User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI