Comtrol ES8108 Series Installation guide

Category
Network switches
Type
Installation guide
Connecting to the Network
Connecting the Ethernet Ports
Connect one end of an Ethernet cable into the Ethernet port of the RocketLinx ES8108 or
ES8108F and the other end to the attached device. All Ethernet ports support auto MDI/MDIX
functionality. The yellow LED is lit for a 100Mbps link and remains off for a 10Mbps link. The
green LED is lit for link up and blinks for packet transmit and receive. The fiber port has one
LED, which is lit if the port is operating in full-duplex mode and blinks when the port is
transmitting or receiving data.
Connecting the Fiber Port (RocketLinx ES8108F)
Connect the fiber port to another Fiber Ethernet device, by following the diagram.
nnect
the
fiber
port
to
another
Fiber
Ethernet
device
,
by
follo
RX
TX
RX
TX
Cable Wiring(SC to SC)
RX A TX B
TX A RX B
A
B
DIP Switch Settings for Alarm Relay Output
P1 to P8
(Pin 1 – 8)
P9
Pin Status Description
ON To enable port link down alarm at this port.
ON To enable power failure alarm.
Off To disable port link down alarm at this port.
Off To disable power failure alarm.
Wiring the Relay Output
The relay alarm output contacts are
in the middle of the terminal block
connector. By inserting the wires
and setting the DIP switch of
the respective Port Alarm to “ON”,
the relay output alarm will detect
any port failures and form a short
circuit. The alarm relay output is
“Normal Open.” The alarm relay output closes if there is a port or power failure.
Maximum 1A current / DC 24V
PW1
Alm
PW2
Alarm Control
port 1~8 power
Alarm
System
Extra Power
System
Quick Installation Guide
ES8108 | ES8108F
www.comtrol.com
2000517 Rev. C
Comtrol Customer Service
Contact Method Web Address or Phone Number
Support http://www.comtrol.com/pub/en/support
Downloads ftp://ftp.comtrol.com/html/ES8108.htm
Web Site http://www.comtrol.com
Phone 763.957.6000
This is a Class 1 Laser/LED product.
Don't stare into the Laser/LED Beam.
ATTENTION
ROCKETLINX ES8108
Industrial Ethernet Switch
3
4
Introduction
Wiring the Power Inputs
The RocketLinx ES8108/ES8108F provides redundant DC power input.
1. Insert the positive and negative wires into the + and - contact either under the PW1 or
PW2 on the terminal block connector.
2. Tighten the wire-clamp screws to prevent the wires from
being loosened.
Note: The recommended working voltage is 24VDC (12-48VDC).
There is an earth ground screw on the
bottom side of the RocketLinx
ES8108/ES8108F. Connect the
earth ground screw of the switch to a
grounding surface to ensure safety
and prevent noise.
Grounding RocketLinx ES8108/ES8108F
The RocketLinx ES8108 and ES8108F series of industrial Ethernet switches conform to
IEE802.3 and 802.3u standards, which includes the following models:
ES8108 supports eight 10/100BASE-TX ports
ES8108F-M (multi-mode) supports six 10/100BASE-TX and two 100BASE-FX fiber ports
ES8108F-S (single-mode) supports six 10/100BASE-TX and two 100BASE-FX fiber ports
The RocketLinx ES8108/ES8108F features an IP30 rated rugged metal housing for operation
in harsh environments (-25
O
C to 70
O
C). It also features a relay alarm output to notify users of
a port link or power failure that can be enabled or disabled using the 9-pin DIP switch. The
RocketLinx ES8108/8108F can be powered using a wide input power range of 12-48VDC
using the 6-pin terminal block.
Package contents Check List
Box contents:
RocketLinx ES8108/ES8108F switch
Quick installation guide
RocketLinx Software and Documentation CD, which contains the ES8108/ES8108F User
Guide. You can refer to the User Guide for detailed installation procedures and
product information.
DIN rail mounting kit
Mounting the Unit
Optionally, mount the RocketLinx ES8108/ES8108F on the DIN rail using the DIN rail clip that
is attached to the rear of the unit.
RocketLinx ES8108
ES8
1
08/
E
S8
1
08
F
U
ser
RocketLinx ES8108F
PW1
Alm
PW2
Alarm Control
port 1~8 power
Earth Ground
Screw
Earth Ground
Warning: Do not connect to AC line – Neutral
V-
V+
V-
V+
RocketLinx ES8108 / ES8108F chassis
Ground should connect with Earth
Ground
Bottom side of
RocketLinx ES8108
RocketLinx ES8108F
Dry Relay Output
PWR 1
PWR 2
12 - 24AWG Wire
12 - 24AWG Wire
DC Power output
DC 12V - 48V
DC 12V - 48V
DC Power output
AC/DC Power Supply
(DC 12V - 48V, 1A:UL Listed)
AC/DC Power Supply
(DC 12V - 48V, 1A:UL Listed)
AC Power input
Earth Ground
AC Power input
Earth Ground
1
2
Comtrol Corporation
+1 763.957.6000
www.comtrol.com
Introduction
Wiring the Power Inputs
The RocketLinx ES8108/ES8108F provides redundant DC power input.
1. Insert the positive and negative wires into the + and - contact either under the PW1 or
PW2 on the terminal block connector.
2. Tighten the wire-clamp screws to prevent the wires from
being loosened.
Note: The recommended working voltage is 24VDC (12-48VDC).
There is an earth ground screw on the
bottom side of the RocketLinx
ES8108/ES8108F. Connect the
earth ground screw of the switch to a
grounding surface to ensure safety
and prevent noise.
Grounding RocketLinx ES8108/ES8108F
The RocketLinx ES8108 and ES8108F series of industrial Ethernet switches conform to
IEE802.3 and 802.3u standards, which includes the following models:
ES8108 supports eight 10/100BASE-TX ports
ES8108F-M (multi-mode) supports six 10/100BASE-TX and two 100BASE-FX fiber ports
ES8108F-S (single-mode) supports six 10/100BASE-TX and two 100BASE-FX fiber ports
The RocketLinx ES8108/ES8108F features an IP30 rated rugged metal housing for operation
in harsh environments (-25
O
C to 70
O
C). It also features a relay alarm output to notify users of
a port link or power failure that can be enabled or disabled using the 9-pin DIP switch. The
RocketLinx ES8108/8108F can be powered using a wide input power range of 12-48VDC
using the 6-pin terminal block.
Package contents Check List
Box contents:
RocketLinx ES8108/ES8108F switch
Quick installation guide
RocketLinx Software and Documentation CD, which contains the ES8108/ES8108F User
Guide. You can refer to the User Guide for detailed installation procedures and
product information.
DIN rail mounting kit
Mounting the Unit
Optionally, mount the RocketLinx ES8108/ES8108F on the DIN rail using the DIN rail clip that
is attached to the rear of the unit.
RocketLinx ES8108
ES8
1
08/
E
S8
1
08
F
U
ser
RocketLinx ES8108F
PW1
Alm
PW2
Alarm Control
port 1~8 power
Earth Ground
Screw
Earth Ground
Warning: Do not connect to AC line – Neutral
V-
V+
V-
V+
RocketLinx ES8108 / ES8108F chassis
Ground should connect with Earth
Ground
Bottom side of
RocketLinx ES8108
RocketLinx ES8108F
Dry Relay Output
PWR 1
PWR 2
12 - 24AWG Wire
12 - 24AWG Wire
DC Power output
DC 12V - 48V
DC 12V - 48V
DC Power output
AC/DC Power Supply
(DC 12V - 48V, 1A:UL Listed)
AC/DC Power Supply
(DC 12V - 48V, 1A:UL Listed)
AC Power input
Earth Ground
AC Power input
Earth Ground
1
2
Comtrol Corporation
+1 763.957.6000
www.comtrol.com
Connecting to the Network
Connecting the Ethernet Ports
Connect one end of an Ethernet cable into the Ethernet port of the RocketLinx ES8108 or
ES8108F and the other end to the attached device. All Ethernet ports support auto MDI/MDIX
functionality. The yellow LED is lit for a 100Mbps link and remains off for a 10Mbps link. The
green LED is lit for link up and blinks for packet transmit and receive. The fiber port has one
LED, which is lit if the port is operating in full-duplex mode and blinks when the port is
transmitting or receiving data.
Connecting the Fiber Port (RocketLinx ES8108F)
Connect the fiber port to another Fiber Ethernet device, by following the diagram.
nnect
the
fiber
port
to
another
Fiber
Ethernet
device
,
by
follo
RX
TX
RX
TX
Cable Wiring(SC to SC)
RX A TX B
TX A RX B
A
B
DIP Switch Settings for Alarm Relay Output
P1 to P8
(Pin 1 – 8)
P9
Pin Status Description
ON To enable port link down alarm at this port.
ON To enable power failure alarm.
Off To disable port link down alarm at this port.
Off To disable power failure alarm.
Wiring the Relay Output
The relay alarm output contacts are
in the middle of the terminal block
connector. By inserting the wires
and setting the DIP switch of
the respective Port Alarm to “ON”,
the relay output alarm will detect
any port failures and form a short
circuit. The alarm relay output is
“Normal Open.” The alarm relay output closes if there is a port or power failure.
Maximum 1A current / DC 24V
PW1
Alm
PW2
Alarm Control
port 1~8 power
Alarm
System
Extra Power
System
Quick Installation Guide
ES8108 | ES8108F
www.comtrol.com
2000517 Rev. C
Comtrol Customer Service
Contact Method Web Address or Phone Number
Support http://www.comtrol.com/pub/en/support
Downloads ftp://ftp.comtrol.com/html/ES8108.htm
Web Site http://www.comtrol.com
Phone 763.957.6000
This is a Class 1 Laser/LED product.
Don't stare into the Laser/LED Beam.
ATTENTION
ROCKETLINX ES8108
Industrial Ethernet Switch
3
4
Connecting to the Network
Connecting the Ethernet Ports
Connect one end of an Ethernet cable into the Ethernet port of the RocketLinx ES8108 or
ES8108F and the other end to the attached device. All Ethernet ports support auto MDI/MDIX
functionality. The yellow LED is lit for a 100Mbps link and remains off for a 10Mbps link. The
green LED is lit for link up and blinks for packet transmit and receive. The fiber port has one
LED, which is lit if the port is operating in full-duplex mode and blinks when the port is
transmitting or receiving data.
Connecting the Fiber Port (RocketLinx ES8108F)
Connect the fiber port to another Fiber Ethernet device, by following the diagram.
,
RX
TX
RX
TX
Cable Wiring(SC to SC)
RX A TX B
TX A RX B
A
B
DIP Switch Settings for Alarm Relay Output
P1 to P8
(Pin 1 – 8)
P9
Pin Status Description
ON To enable port link down alarm at this port.
ON To enable power failure alarm.
Off To disable port link down alarm at this port.
Off To disable power failure alarm.
Wiring the Relay Output
The relay alarm output contacts are
in the middle of the terminal block
connector. By inserting the wires
and setting the DIP switch of
the respective Port Alarm to “ON”,
the relay output alarm will detect
any port failures and form a short
circuit. The alarm relay output is
“Normal Open.” The alarm relay output closes if there is a port or power failure.
Maximum 1A current / DC 24V
PW1
Alm
PW2
Alarm Control
port 1~8 power
Alarm
System
Extra Power
System
Quick Installation Guide
ES8108 | ES8108F
www.comtrol.com
2000517 Rev. C
Comtrol Customer Service
Contact Method Web Address or Phone Number
Support http://www.comtrol.com/pub/en/support
Downloads ftp://ftp.comtrol.com/html/ES8108.htm
Web Site http://www.comtrol.com
Phone 763.957.6000
This is a Class 1 Laser/LED product.
Don't stare into the Laser/LED Beam.
ATTENTION
ROCKETLINX ES8108
Industrial Ethernet Switch
3
4
Introduction
Wiring the Power Inputs
The RocketLinx ES8108/ES8108F provides redundant DC power input.
1. Insert the positive and negative wires into the + and - contact either under the PW1 or
PW2 on the terminal block connector.
2. Tighten the wire-clamp screws to prevent the wires from
being loosened.
Note: The recommended working voltage is 24VDC (12-48VDC).
There is an earth ground screw on the
bottom side of the RocketLinx
ES8108/ES8108F. Connect the
earth ground screw of the switch to a
grounding surface to ensure safety
and prevent noise.
Grounding RocketLinx ES8108/ES8108F
The RocketLinx ES8108 and ES8108F series of industrial Ethernet switches conform to
IEE802.3 and 802.3u standards, which includes the following models:
ES8108 supports eight 10/100BASE-TX ports
ES8108F-M (multi-mode) supports six 10/100BASE-TX and two 100BASE-FX fiber ports
ES8108F-S (single-mode) supports six 10/100BASE-TX and two 100BASE-FX fiber ports
The RocketLinx ES8108/ES8108F features an IP30 rated rugged metal housing for operation
in harsh environments (-25
O
C to 70
O
C). It also features a relay alarm output to notify users of
a port link or power failure that can be enabled or disabled using the 9-pin DIP switch. The
RocketLinx ES8108/8108F can be powered using a wide input power range of 12-48VDC
using the 6-pin terminal block.
Package contents Check List
Box contents:
RocketLinx ES8108/ES8108F switch
Quick installation guide
RocketLinx Software and Documentation CD, which contains the ES8108/ES8108F User
Guide. You can refer to the User Guide for detailed installation procedures and
product information.
DIN rail mounting kit
Mounting the Unit
Optionally, mount the RocketLinx ES8108/ES8108F on the DIN rail using the DIN rail clip that
is attached to the rear of the unit.
RocketLinx ES8108
ES8
1
08/
E
S8
1
08
F
U
ser
RocketLinx ES8108F
PW1
Alm
PW2
Alarm Control
port 1~8 power
Earth Ground
Screw
Earth Ground
Warning: Do not connect to AC line – Neutral
V-
V+
V-
V+
RocketLinx ES8108 / ES8108F chassis
Ground should connect with Earth
Ground
Bottom side of
RocketLinx ES8108
RocketLinx ES8108F
Dry Relay Output
PWR 1
PWR 2
12 - 24AWG Wire
12 - 24AWG Wire
DC Power output
DC 12V - 48V
DC 12V - 48V
DC Power output
AC/DC Power Supply
(DC 12V - 48V, 1A:UL Listed)
AC/DC Power Supply
(DC 12V - 48V, 1A:UL Listed)
AC Power input
Earth Ground
AC Power input
Earth Ground
1
2
Comtrol Corporation
+1 763.957.6000
www.comtrol.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Comtrol ES8108 Series Installation guide

Category
Network switches
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI