Kozyheat Callaway 50 Owner's manual

Category
Fireplaces
Type
Owner's manual

This manual is also suitable for

HUSSONG MANUFACTURING CO., INC.
READ ALL THESE STEPS
BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE
APPLIANCE.
This kit must be installed by a qualied installer,
service agency, or gas supplier at the time of
the heater installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the appliance.
Please read the appliance owner’s manual
completely before performing any procedures in
these instructions.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
KOMFORT ZONE KIT
#KZK-1510A
For use with the #BHM-44, #CLW-ST, and #CLW-
50 (Starting Serial Number: 19 501780 50)
This optional convection duct kit redistributes the
warm air ow away from the replace opening to
a more desirable location using natural convection
without the use of a fan. The warm air ow may be
relocated to a position higher up the wall, out the
sidewalls, or even to an adjacent room. The result
is much cooler wall temperatures above the re-
place opening for locating televisions, artwork, etc.
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d’installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez
www.kozyheat.com
.
Hussong Manufacturing Co., Inc.
P.O. Box 577, 204 Industrial Park Drive
Lakeeld, MN 56150-0577, USA Rev. 6, 4/21
1.0 INTRODUCTION .......................................................................3
1.1 Kit Contents..........................................................................................3
1.2 Fireplace Preparation ........................................................................3
1.3 Suggested Congurations .............................................................. 4
1.4 Dimensions and Overview .............................................................7
1.5 Air Duct Pipe Run ...............................................................................8
2.0 FRAMING AND CLEARANCES ................................................9
2.1 Clearance to Sprinkler ...................................................................... 9
2.2 Framing................................................................................................10
2.3 Shelf Requirements .........................................................................14
2.4 CLW-ST Front Facing Clearances ................................................16
3.0 FACING AND FINISHING .......................................................17
3.1 Non-combustible Requirements ................................................ 17
3.2 Combustible Finish .......................................................................... 20
3.3 Hearth and Mantel Clearances ....................................................24
4.0 INSTALLATION .......................................................................27
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 3
1.1 Kit Contents
ALL kit contents must be installed.
(2) 15" plenum kit: #KZK-1510A
(2) air grilles
(8) 6" collars - (4) to attach to the bottom of the plenum; (4) to
attach to the unit where the cover plates are removed.
(1) KZK-410-6 is used for a 10' vent run. If you are mounting the
plenum above the replace 10' (3m) or less, use (1) #KZK-410-6 kit.
KZK-CPL6 is (6) 6" couplers that connect (2) KZK-410-6. You will only
need (4) 6" couplers for installation. If you are mounting the plenum
above the replace between 10' to 20', you will need (2) KZK-410-6 kit
and (1) #KZK-CPL6 coupler kit.
1.0 INTRODUCTION
15¾”
(400mm)
11
¾
(298mm)
(4) take o collars included
#KZK-1510A
Figure 1.1, #KZK-1510A
Figure 1.2, #KZK-410-6
(4) - 10’ x 6” (aluminum ex) listed to UL-181Class 0 Air Duct
#KZK-410-6
Figure 1.3, BHM-44 Stand-o Assembly Installation
Discard header heat shield
Stand-o
assembly
1.2 Fireplace Preparation
1.2.1 BHM-44 Requirements
For ease of installation, the header heat shield may be removed.
The stand-o assembly still must be installed. To install stand-o
assembly,
1. Locate the stand-o assembly and header heat shield on top of
the replace, as shipped.
2. Discard header heat shield.
3. Attach the stand-o assembly pieces as shown below and secure
with (4) screws.
4 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
1.3 Suggested Congurations
When installing the #KZK-1510A, take in consideration the replace
venting and the plenum tube conguration.
The (2) plenums and the (2) air grilles in this kit are required and both
must be installed.
Figure 1.4, #KZK-1510A Suggested Congurations for CLW-50
#KZK-1510A side wall outlet
#KZK-1510A rear wall outlet
CLW-50
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 5
Figure 1.5, #KZK-1510A Suggested Conguration for CLW-ST
#KZK-1510A front wall outlet
Access/front
side
Fixed/back
side
CLW-ST
6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
Figure 1.6, #KZK-1510A Suggested Congurations for BHM-44
#KZK-1510A side wall outlet
#KZK-1510A rear wall outlet
BHM-44
For side wall outlet installations, it is easier to keep the 1/2” (12mm) clearance if
the center tubes are assembled to the backside of the KZK
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 7
1.4 Dimensions and Overview
Figure 1.7, #KZK-1510A Dimensions
7⁄
(198mm)
13
½
(342mm)
3”
(76mm)
12”
(304mm)
5
⁄
(149mm)
8
⁄
(220mm)
4”
(102mm)
6”
(152mm)
1
½
(38mm)
¾
(19mm)
stando
stando
#KZK-1510A
8 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
1.5 Air Duct Pipe Run
IMPORTANT: The air duct pipe cannot run horizontally without a
vertical rise.
IMPORTANT: The 1/2" clearance around the air duct pipes must be
maintained.
Use #KZK-410-6 UL181 Class 0 Air Duct piping to connect the plenum(s)
to the unit.
Hussong Mfg. requires pipes to be listed as UL181 Class 0 Air Duct to
connect the plenum(s) to the unit.
CLW-50, CLW-ST, & BHM-44 maximum vent run: 20' (6m)
Figure 1.8, Minimum Vent Pipe Run - only (1) plenum shown
WHEN INSTALLING AIR DUCT PIPE MAINTAIN A MINIMUM 4" VERTICAL RISE FOR EVERY 12" HORIZONTAL RUN
12”
(304mm)
4” (102mm)
Minimum bend radius=5” (127mm)
CLW-50
12”
(304mm)
4” (102mm)
Minimum bend radius=6” (152mm)
BHM-44
12”
(304mm)
4” (102mm)
Minimum bend radius=5” (127mm)
CLW-ST
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 9
2.0 FRAMING AND CLEARANCES
Figure 2.1, KZK Clearance to Sprinkler
2.1 Clearance to Sprinkler
In a situation where a sprinkler head is installed within the
proximity to a #KZK discharge opening, the diagram below
MUST be followed.
The distance between a sprinkler head and discharge opening
cannot be less than 60" (1524mm) in length at every point from
the origin of the discharge opening. You must also verify the
sprinkler head sensor is set to the proper heat setting so it does
not activate when the room heats up from the replace being
operated normally.
Please follow local building codes to determine what
temperature setting is relevant for your installation.
3”
(76mm)
MIN
60”
(1524mm)
MIN
3”
(76mm)
MIN
60”
(1524mm)
MIN
3”
(76mm)
MIN
60”
(1524mm)
MIN
CLW-50
BHM-44
CLW-ST
Ceiling
sprinkler head
Ceiling
sprinkler head
Ceiling
sprinkler head
10 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
2.2 Framing
Shown in this section are rough opening dimensions and clearances
for the plenums, unit installation, and unit installation with a TV
recess construction.
Rough opening framing dimensions should allow for wall covering
thickness and facing materials.
Figure 2.2, Minimum Clearances for Plenum Air Discharge to Ceiling
½
(12mm)
½
(12mm)
3”
(76mm)
1
½
(38mm)
Ceiling
½
(12mm)
½
(12mm)
3”
(76mm)
1
½
(38mm)
Ceiling
CLW-50 CLW-ST
½
(12mm)
½
(12mm)
3”
(76mm)
1
½
(38mm)
Ceiling
BHM-44
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 11
8¼
(209mm)
18”
(457mm)
74
½
(1892mm)
66
¼
(1683mm)
76”
(1930mm)
22”
(558mm)
STEEL
FRAMING
Plenum rough opening
Height and Width
Unit and plenum
side view
CLW-50
Figure 2.3, CLW-50 Rough Opening and Framing for #KZK-1510A
Figure 2.4, CLW-50 Unit Wall Enclosure Rough Opening
76”
(1930mm)
48”
(1219mm)
64
½
(1638mm)
22”
(559mm)
44
½
(1130mm)
4
¼
(108mm)
76”
(1930mm)
64
½
(1638mm)
22”
(559mm)
44
½
(1130mm)
4
¼
(108mm)
Steel Framing Required
Steel Framing Required
CLW-50
Dimensions reect minimum enclosure height
Dimensions reect minimum enclosure height
12 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
Figure 2.5, CLW-ST Rough Opening and Framing for #KZK-1510A
8¼
(210mm)
18”
(457mm)
74
½
(1892mm)
66
¼
(1683mm)
17”
(432mm)
18”
(457mm)
Ceiling
Plenum rough opening
Unit and plenum side view
CLW-ST
Dimensions reect minimum enclosure height
76”
(1930mm)
43
¼
(1098mm)
64
½
(1638mm)
17”
(559mm)
Ceiling/Fireplace enclosure top
Single vertical
header
CLW-ST
Figure 2.6, CLW-ST Unit Wall Enclosure Rough Opening
Dimensions reect minimum enclosure height
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 13
8¼
(209mm)
18”
(457mm)
86
½
(2197mm)
78
¼
(1988mm)
88”
(2235mm)
22”
(558mm)
Plenum rough opening
Height and Width
Unit and plenum
side view
BHM-44
Figure 2.7, BHM-44 Rough Opening and Framing for #KZK-1510A
Figure 2.8, BHM-44 Unit Wall Enclosure Rough Opening
60½
(1537mm)
88”
(2235mm)
46
¼
(1175mm)
57
⁄
(1463mm)
22”
(558mm)
4
¼
(108mm)
88”
(2235mm)
46
¼
(1175mm)
Double horizontal
header
Ceiling/Fireplace enclosure top
Ceiling/Fireplace
enclosure top
TV Recess
BHM-44
Dimensions reect minimum enclosure height
Dimensions reect minimum enclosure height
14 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
2.3 Shelf Requirements
The drawings in this section show the framing requirements if
you desire the air discharge opening to be located within the
bump-out or bookshelf framing, or the pocket enclosure (for unit
CLW-ST).
2.3.1 CLW-50 Requirements
NOTE: For the CLW-50, take careful consideration in the dierence
of the minimum chamber height of the replace compared to the
minimum height of the shelf enclosure.
7”
(178mm)
MIN
22”
(559mm)
MAX
76”
(1930mm)
MIN
2”
(51mm)
MIN
76”
(1930mm)
MIN
82
¾
(2102mm)
MIN
7”
(178mm) MIN
18”
(457mm)
MIN
3”
(76mm)
MIN
22”
(559mm)
MIN
22”
(559mm)
MIN
3”
(76mm)
MIN
7”
(178mm)
MIN
82
¾
(2102mm)
MIN
18”
(457mm)
MIN
Ceiling
Enclosure Top
Grille
Enclosure Floor Enclosure Floor
Grille
CLW-50
Figure 2.9, CLW-50 Shelf Requirements
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 15
3”
(76mm)
MIN
0” (0mm)
MIN
18”
(457mm)
MIN
16”
(406mm)
MIN
22”
(559mm)
MAX
88”
(2235mm)
MIN
0” (0mm)
MIN
18”
(457mm)
MIN
16”
(406mm)
0” (0mm) MIN
88”
(2235mm)
MIN
BHM-44
Grille
Enclosure Top
Enclosure Floor
Ceiling
Enclosure Floor
Grille
Figure 2.10, BHM-44 Shelf Requirements
2.3.2 BHM-44 Requirements
16 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
Figure 2.11, CLW-ST Front Facing Clearances
2.4 CLW-ST Front Facing Clearances
Figure 2.11 below shows the front facing clearance requirements for
the CLW-ST for the KZK-1510A air discharge opening.
2”
(51mm)
18”
(457mm)
76”
(1930mm)
2”
(51mm)
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 17
3.0 FACING AND FINISHING
3.1 Non-combustible Requirements
3¾
(95mm)
13”
(330mm)
9
¾
(248mm)
1
½
(38mm)
13”
(330mm)
3
¾
(95mm)
No Screws Allowed
No Screws Allowed
No Screws Allowed
Non-Combustible Finishing Material Only
SCREW PATTERN LOCATIONS
Figure 3.1, CLW-50 Minimum Non-combustible Finishing Dimensions
Figure 3.2, CLW-50 Minimum Non-combustible Finishing Dimensions Screw Locations
21½
(545mm)
66”
(1676mm)
6
⁄
(161mm)
48
¾
(1238mm)
53
½
(1359mm)
16
¾
(425mm)
10
½
(267mm)
Combustible Finishing
Material Allowed
Non-Combustible Finishing Material Only
Steel Framing Required
Lower Cover Panel
Combustible Finishing Material Allowed
CLW-50
Non-combustible
nishing material only
Combustible nishing
material allowed
Combustible nishing material
allowed. See image below for
acceptable screw locations.
18 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
7”
(178mm)
16
¾
(425mm)
67
½
(1714mm)
18”
(457mm)
53
½
(1359mm)
45
¼
(1149mm)
10
½
(267mm)
Combustible nishing
material allowed
Non-combustible nishing material only
Lower cover panel
Combustible nishing material allowed
Non-combustible
nishing material only
Combustible nishing
material allowed
Combustible nishing material
allowed. See image below for
acceptable screw locations.
CLW-ST
59½
(1512mm)
2
½
(64mm)
1
½
(38mm)
9
¾
(248mm)
Non-combustible nishing material only
No Screws Allowed
No Screws Allowed
Screw Pattern Locations
Figure 3.3, CLW-ST Minimum Non-combustible Finishing Dimensions
Figure 3.4, CLW-ST Minimum Non-combustible Finishing Dimensions Screw Locations
Komfort Zone Kit #KZK-1510A R.6 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 19
Figure 3.5, BHM-44 Minimum Non-combustible Finishing Dimensions
2½
(63mm)
44
½
(1130mm)
24
⁄
(633mm)
1
½
(38mm)
45
⁄
(1148mm)
8
⁄
(205mm)
60
⁄
(1540mm)
Combustible nishing material allowed
Non-combustible nishing material only
BHM-44
Combustible nishing
material allowed
Non-combustible
nishing material only
20 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.6
3.2 Combustible Finish
NOTE: If you desire to run nishing material up to edge of the discharge
opening, see drawing below. Finishing material must not block the air
discharge grille and must run evenly along the plenum opening.
WARNING! RISK OF OVERHEATING AND FIRE! Ensure the KZK duct
system is installed in accordance to this manual AND the convection
bae is removed when using these combustible clearances.
3.2.1 Drywall Finish
IMPORTANT: Additional 1" (25mm) combustible trim on top of
existing materials is NOT allowed inside the side shelf enclosure
(Section 2.3 on page 14) or the pocket enclosure (Section 2.4 on
page 16).
1" (25mm) combustible material goes on top of any required non-
combustible material required on the replace as shown in Figures
3.1 and 3.2 on page 17 for CLW-50, Figures 3.3 and 3.4 on page 18 for
CLW-ST, and Figure 3.5 on page 19 for BHM-44.
Figure 3.6, #KZK-1510A Drywall Finish and Combustible Finishing Material up to 1" Thick
15½
(368mm)
7
¼ (184mm)
15
⁄
(403mm)
11
⁄
(301mm)
11
⁄
(301mm)
NOT ALLOWED INSIDE MINIMUM SHELF ENCLOSURE
OR MINIMUM POCKET ENCLOSURE
Drywall stops at edge of air discharge opening.
Air grille discharge will overlap edges of drywall.
Up to 1” (25mm) thick combustible material up to edge of the air discharge grille.
1” combustible material cannot go closer to discharge opening.
1” combustible material goes on top of any required non-combustible material required on replace.
Combustible
Material up to
1” (25mm) thick
Discharge Grille
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57

Kozyheat Callaway 50 Owner's manual

Category
Fireplaces
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages