GE GTDP400EMWS Installation guide

Type
Installation guide
WARNING RISK OF FIRE
 7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQ
LQVWUXFWLRQV
 &ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
 ,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQ
DFFRUGDQFHZLWKORFDOFRGHV
 7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
 8VHRQO\µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWR
WKHRXWGRRUV
 DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV
,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLWPXVWEH
8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVIRXQG
LQConnecting The Dryer To House Vent RQSDJHRIWKLVPDQXDO
)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQWRFROODSVHEHHDVLO\FUXVKHG
DQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQG
LQFUHDVHWKHULVNRI¿UH
 'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOG
EHH[SRVHGWRZDWHUDQGRUZHDWKHU
 6DYHWKHVHLQVWUXFWLRQVInstallers:%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
 ,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHPDQXIDFWXUHU·V
LQVWUXFWLRQVDQGORFDOFRGHV
NOTE: Installation and service of this dryer
requires basic mechanical and electrical
skills. It is your responsibility to contact
a quali¿ed installer to make the electrical
connections.
Installation
Instructions
Electric Dryer
04
Questions on Installation? Call: 800.GE.CARES (US)
RUYLVLWRXUZHEVLWHDWwww.GEAppliances.com (US)
BEFORE YOU BEGIN
Read these instructions completely and carefully.

IMPORTANT-6DYHWKHVHLQVWUXFWLRQV
IRUORFDOLQVSHFWRU·VXVH
 IMPORTANT-2EVHUYHDOOJRYHUQLQJ
FRGHVDQGRUGLQDQFHV
Note to Installer -%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
 Note to Customer -.HHSWKHVHLQVWUXFWLRQV
ZLWK\RXU2ZQHU·V0DQXDOIRUIXWXUHUHIHUHQFH
 %HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU
GLVFDUGHGUHPRYHWKHGU\HUGRRU
 ,QVSHFWWKHGU\HUH[KDXVWRXWOHWDQGVWUDLJKWHQ
WKHRXWOHWZDOOVLIWKH\DUHEHQW
 6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDP
DUHORFDWHGLQWKHFRQWUROFRQVROH
 'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH
&ORVHVXSHUYLVLRQRIFKLOGUHQLVQHFHVVDU\ZKHQ
WKHDSSOLDQFHLVXVHGQHDUFKLOGUHQ
 ,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLV
DERYH)IRUVDWLVIDFWRU\RSHUDWLRQRIWKH
GU\HUFRQWUROV\VWHP
 3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQ
LVQRWFRYHUHGXQGHUWKHZDUUDQW\
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
LEVEL
TOOLS YOU WILL NEED
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT (IF NEEDED.)
DUCT TAPE
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
4” COVER PLATE (IF NEEDED
(KIT WE1M454)
234D1582P004 31-16224-2 03-12 GE
6WHS3UHSDUHWKH$UHDDQG([KDXVWIRU,QVWDOODWLRQRI
1HZ'U\HUVHHVHFWLRQ
6WHS&KHFNDQG(QVXUHWKH([LVWLQJ([WHUQDO([KDXVWLV
&OHDQVHHVHFWLRQDQG0HHWV$WWDFKHG,QVWDOODWLRQ
6SHFL¿FDWLRQVVHHVHFWLRQ
6WHS5HPRYHWKH)RDP6KLSSLQJ3DGVVHHVHFWLRQ
6WHS0RYHWKH'U\HUWRWKH'HVLUHG/RFDWLRQ
6WHS&RQQHFWWKH3RZHU6XSSO\VHHVHFWLRQ
6WHS&RQQHFWWKH([WHUQDO([KDXVWVHHVHFWLRQ
6WHS/HYHO<RXU'U\HUVHHVHFWLRQ
6WHS&KHFNWKH2SHUDWLRQRIWKH3RZHU6XSSO\9HQWLQJ
6WHS3ODFHWKH2ZQHU·V0DQXDODQGWKH,QVWDOODWLRQ
,QVWUXFWLRQVLQDORFDWLRQZKHUHWKH\ZLOOEHQRWLFHGE\WKH
RZQHU
)RU$OFRYHRU&ORVHW,QVWDOODWLRQVHHVHFWLRQ
)RU%DWKURRPRU%HGURRP,QVWDOODWLRQVHHVHFWLRQ
)RU0RELOHRU0DQXIDFWXUHG+RPHVHHVHFWLRQ
)RUJDUDJHLQVWDOODWLRQLIDOORZHGE\ORFDOFRGHVVHHVHFWLRQ
)RUVLGHRUERWWRPH[KDXVWVHHVHFWLRQ
Installation Instructions
2
Minimum Clearance Other Than Alcove or Closet Installation
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU
&RQVLGHUDWLRQmustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQDQGVHUYLFH
1
PREPARING FOR INSTALLATION
OF NEW DRYER
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer
exhaust.
REMOVING LINT FROM WALL
EXHAUST OPENING
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
2
ELECTRICAL CONNECTION
INFORMATION
WARNING - TO REDUCE THE RISK
OF FIRE, ELECTRICAL SHOCK AND PERSONAL
INJURY:
DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFHZLWK
ORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFHRIORFDO
FRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/(/(&75,&$/
&2'($16,1)3$12
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: SInce January 1,1996, the National Electric code
requires that the new constructions utilize a 4-wire
connection to an electric dryer.
WARNING:Only a 4-conductor cord shall be
used when the appliance is installed in a location where
grounding through the neutral conductor is prohibited.
Grounding through the neutral is prohibited for the new
branch-circuit installations, mobile homes, recreational
vehicles, and areas where local codes prohibit
grounding through the neutral conduction.
7XUQRȺWKHFLUFXLWEUHDNHUVDPSRUUHPRYHWKH
GU\HU·VFLUFXLWIXVHDWWKHHOHFWULFDOER[
%HVXUHWKHGU\HUFRUGLVXQSOXJJHGIURPWKHZDOO
UHFHSWDFOH
5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHU
EDFN
5HPRYHDQGGLVFDUGJURXQGVWUDS.HHSWKHJUHHQ
JURXQGVFUHZIRUVWHS
,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
HQWU\KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWSRZHUFRUGDVIROORZV
$&RQQHFWWKHKRWOLQHVWRWKHRXWHUVFUHZVRI
WKHWHUPLQDOEORFNPDUNHG/DQG/
%&RQQHFWWKHQHXWUDOZKLWHOLQHWRWKHFHQWHURI
WKHWHUPLQDOEORFNPDUNHG1
$WWDFKJURXQGZLUHRISRZHUFRUGZLWKWKHJUHHQ
JURXQGVFUHZKROHDERYHVWUDLQUHOLHIEUDFNHW7LJKWHQ
DOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUFRUGWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
L1
N
L2
RELOCATE GREEN
GROUND SCREW
HERE
STRAIN
RELIEF
BRACKET
GREEN OR
YELLOW WIRE
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
SCREWS
(3)
HOT
WIRE
COVER
NEUTRAL
(White)
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
INTERNAL DUCT
OPENING
CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
ELECTRICAL REQUIREMENTS
7KLVGU\HUPXVWEHFRQQHFWHGWRDQLQGLYLGXDO
EUDQFKFLUFXLWSURWHFWHGE\WKHUHTXLUHGWLPHGHOD\
IXVHVRUFLUFXLWEUHDNHUV$IRXURUWKUHHZLUHVLQJOH
SKDVH9RU9+]DPSFLUFXLW
LVUHTXLUHG,IWKHHOHFWULFVXSSO\GRHVQRWPHHWWKH
DERYHVSHFL¿FDWLRQVWKHQFDOODOLFHQVHGHOHFWULFLDQ
GROUNDING INSTRUCTIONS
7KLVGU\HUPXVWEHFRQQHFWHGWRDJURXQGHGPHWDO
SHUPDQHQWZLULQJV\VWHPRUDQHTXLSPHQWJURXQGLQJ
FRQGXFWRUPXVWEHUXQZLWKWKHFLUFXLWFRQGXFWRUVDQG
FRQQHFWHGWRWKHHTXLSPHQWJURXQGLQJWHUPLQDORQWKH
DSSOLDQFH
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
Installation Instructions
3
CONNECTING DRYER USING 3-WIRE
CONNECTION
3-wire Connection
1RWIRUXVHLQ&DQDGD
'2127XVHIRU0RELOH+RPH,QVWDOODWLRQV
127IRUXVHRQQHZFRQVWUXFWLRQ
127IRUXVHRQUHFUHDWLRQDOYHKLFOHV
127IRUXVHLQDUHDVZKHUHORFDOFRGHVSURKLELW
JURXQGLQJWKURXJKWKHQHXWUDOFRQGXFWLRQ
7XUQRȺWKHFLUFXLWEUHDNHUVDPSRUUHPRYHWKH
GU\HU·VFLUFXLWIXVHDWWKHHOHFWULFDOER[
%HVXUHWKHGU\HUFRUGLVXQSOXJJHGIURPWKHZDOO
5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHU
EDFN
,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
HQWU\KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWSRZHUFRUGDVIROORZV
$&RQQHFWWKHKRWOLQHVWRWKHRXWHUVFUHZVRI
WKHWHUPLQDOEORFNPDUNHG/DQG/
%&RQQHFWWKHQHXWUDOZKLWHOLQHWRWKHFHQWHU
RIWKHWHUPLQDOEORFNPDUNHG1
%HVXUHJURXQGVWUDSLVFRQQHFWHGWRQHXWUDOFHQWHU
WHUPLQDORIEORFNDQGWRJUHHQJURXQGVFUHZRQFDEL
QHWUHDU7LJKWHQDOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUFRUGWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
L1
L2
STRAIN RELIEF
BRACKET
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
HOT
WIRE
GROUND
STRAP
GREEN
GROUND
SCREW
NEUTRAL
(White)
SCREWS
(3)
IF REQUIRED, BY LOCAL CODE,
INSTALL EXTERNAL GROUND
(NOT PROVIDED) TO GROUNDED
METAL, COLD WATER PIPE, OR
OTHER ESTABLISHED GROUND
DETERMINED BY A QUALIFIED
ELECTRICIAN.
COVER
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
3
EXHAUST INFORMATION
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\
RIELUGVRURWKHUZLOGOLIH
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWR
WKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQR
PDLQWHQDQFHWRSUHYHQWFORJJLQJ
NeverLQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
FRXOGFDXVHOLQWEXLOGXS
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQG
OHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHG
GRZQ
SEPARATION OF TURNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIW
RIVWUDLJKWGXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQG
H[KDXVWKRRG
TURNS OTHER THAN 90º
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
WARNING - IN CANADA AND IN
THE UNITED STATES, THE REQUIRED EX-
HAUST DUCT DIAMETER IS 4 IN (102mm). DO
NOT USE DUCT LONGER THAN SPECIFIED IN
THE EXHAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
,QFUHDVHWKHGU\LQJWLPHVDQGWKHHQHUJ\FRVW
5HGXFHWKHGU\HUOLIH
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
The correct exhaust installation is YOUR
RESPONSIBILITY. Problems due to incorrect
installation are not covered by the warranty.
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQ
GXFW
7KHMAXIMUM ALLOWABLEGXFWOHQJWKDQGQXPEHURI
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRI
GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOO
FDSDQGDOOFRQGLWLRQVQRWHGEHORZ7KHPD[LPXP
GXFWOHQJWKIRUULJLGPHWDOGXFWLVVKRZQLQWKHWDEOH
EHORZ
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elb ows
Rigid
Metal
Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
0
1
2
3
4
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
Use only for sho rt
run installations
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
Installation Instructions
4
5
LEVELING AND STABILIZING YOUR DRYER
LEVEL
SIDE-TO-SIDE.
4 LEVELING LEGS
LEVEL
FRONT-TO-BACK.
EXHAUST INFORMATION (cont)
SEALING OF JOINTS
$OOMRLQWVVKRXOGEHWLJKWWRDYRLGOHDNV7KHPDOHHQGRI
HDFKVHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
'RQRWDVVHPEOHWKHGXFWZRUNZLWKIDVWHQHUVWKDW
H[WHQGLQWRWKHGXFW7KH\ZLOOVHUYHDVDFROOHFWLRQ
SRLQWIRUOLQW
'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\
ZUDSSLQJWKHRYHUODSSHGMRLQWVZLWKGXFWWDSH
+RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV
LQFKSHUIRRW
INSULATION
'XFWZRUNWKDWUXQVWKURXJKDQXQKHDWHGDUHDRULV
QHDUDLUFRQGLWLRQLQJVKRXOGEHLQVXODWHGWRUHGXFH
FRQGHQVDWLRQDQGOLQWEXLOGXS
NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.
HOWEVER, IF FLEXIBLE DUCTING IS USED IT MUST BE UL-LISTED METAL
NOT PLASTIC.
DUCT TAPE OR
DUCT CLAMP
4” METAL DUCT
(CUT TO PROPER
LENGTH)
DUCT TAPE OR
DUCT CLAMP
EXTERNAL
DUCT
OPENING
FOR STRAIGHT LINE INSTALLATION,
CONNECT THE DRYER EXHAUST TO
THE EXTERNAL EXHAUST HOOD
USING DUCT TAPE OR CLAMP.
STANDARD REAR EXHAUST
(Vented at floor level)
4
EXHAUST CONNECTION
THIS DRYER COMES READY FOR REAR
EXHAUSTING. IF SPACE IS LIMITED, USE
THE INSTRUCTIONS IN SECTION 10 TO
EXHAUST DIRECTLY FROM THE SIDES OR
BOTTOM OF THE CABINET.
WARNING - TO REDUCE THE
RISK OF FIRE OR PERSONAL INJURY:
7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUWKHKRPHH[KDXVW
GXFW
8VHRQO\µULJLGPHWDORU8/OLVWHGÀH[LEOHPHWDO
VHPLULJLGRUIRLOW\SHGXFWWRFRQQHFWWKHGU\HU
WRWKHKRPHH[KDXVWGXFW,WPXVWEHLQVWDOOHG
LQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVIRXQGLQ
´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµRQSDJHRI
WKLVPDQXDO
'RQRWWHUPLQDWHH[KDXVWLQDFKLPQH\DZDOO
DFHLOLQJJDVYHQWFUDZOVSDFHDWWLFXQGHUDQ
HQFORVHGÀRRURULQDQ\RWKHUFRQFHDOHGVSDFH
RIDEXLOGLQJ7KHDFFXPXODWHGOLQWFRXOGFUHDWHD
SRWHQWLDO¿UHKD]DUG
1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFW
ZLWKDNLWFKHQH[KDXVWV\VWHP$FRPELQDWLRQRI
JUHDVHDQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW
OHQJWKWDEOH/RQJHUGXFWVFDQDFFXPXODWHOLQW
FUHDWLQJDSRWHQWLDO¿UHKD]DUG
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
ZLOOFDXVHOLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UH
KD]DUG
'RQRWDVVHPEOHGXFWZRUNZLWKDQ\IDVWHQHUV
WKDWH[WHQGLQWRWKHGXFW7KHVHIDVWHQHUVFDQ
DFFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU
3URYLGHDQDFFHVVIRULQVSHFWLRQDQGFOHDQLQJRI
WKHH[KDXVWV\VWHPHVSHFLDOO\DWWXUQVDQGMRLQWV
([KDXVWV\VWHPVKDOOEHLQVSHFWHGDQGFOHDQHGDW
OHDVWRQFHD\HDU
RECOMMENDED
CONFIGURATION
TO MINIMIZE
EXHAUST
BLOCKAGE.
ELBOW HIGHLY
RECOMMENDED
ELBOW HIGHLY
RECOMMENDED
NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.
STANDARD REAR EXHAUST
(Vented above floor level)
Installation Instructions
5
CONNECTING THE DRYER TO HOUSE VENT
RIGID METAL TRANSITION DUCT
)RUEHVWGU\LQJSHUIRUPDQFHDULJLGPHWDOWUDQVLWLRQGXFWLV
UHFRPPHQGHG
5LJLGPHWDOWUDQVLWLRQVGXFWVUHGXFHWKHULVNRIFUXVKLQJDQG
NLQNLQJ
UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOHPHWDO
VHPLULJLGGXFWLQJFDQEHXVHG.LW:;;
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
)RUPDQ\DSSOLFDWLRQVLQVWDOOLQJHOERZVDWERWKWKHGU\HU
DQGWKHZDOOLVKLJKO\UHFRPPHQGHGVHHLOOXVWUDWLRQVEHORZ
(OERZVDOORZWKHGU\HUWRVLWFORVHWRWKHZDOOZLWKRXWNLQNLQJ
DQGRUFUXVKLQJWKHWUDQVLWLRQGXFWPD[LPL]LQJGU\LQJ
SHUIRUPDQFH
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
,QVSHFLDOLQVWDOODWLRQVLWPD\EHQHFHVVDU\WRFRQQHFWWKH
GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW
$8/OLVWHGÀH[LEOHPHWDOIRLOW\SHGXFWPD\EHXVHG21/<
LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG
GXFWLQJFDQQRWEHXVHG$1'ZKHUHDµGLDPHWHUFDQEH
PDLQWDLQHGWKURXJKRXWWKHHQWLUHOHQJWKRIWKHWUDQVLWLRQ
GXFW
,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO
W\SHGXFWVWKDWFRPSO\ZLWKWKH´2XWOLQHIRU&ORWKHV'U\HU
7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
)RUEHVWGU\LQJSHUIRUPDQFH
6OLGHRQHHQGRIWKHGXFWRYHUWKHFORWKHVGU\HURXWOHWSLSH
6HFXUHWKHGXFWZLWKDFODPS


:LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFWWR
LWVIXOOOHQJWK$OORZµRIGXFWWRRYHUODSWKHH[KDXVWSLSH
&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKW
DVSRVVLEOHIRUPD[LPXPDLUÀRZ
6HFXUHWKHGXFWWRWKHH[KDXVWSLSHZLWKWKHRWKHUFODPS
DO
ELBOW HIGHLY
RECOMMENDED
ELBOWS HIGHLY
RECOMMENDED
DON’T
DO NOT USE
EXCESSIVE
EXHAUST
LENGTH
DO NOT
CRUSH
FLEXIBLE
EXHAUST
AGAINST
WALL
DO NOT
SIT DRYER
ON FLEXIBLE
EXHAUST
7
BATHROOM OR BEDROOM INSTALLATION
7KHGU\HUMUSTEHYHQWHGWRWKHRXWGRRUV6HH
EXHAUST INFORMATIONVHFWLRQ
7KHLQVWDOODWLRQPXVWFRQIRUPZLWKORFDOFRGHVRULQWKH
DEVHQFHRIORFDOFRGHVZLWKWKHNATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.
8
MOBILE OR MANUFACTURED HOME
INSTALLATION
,QVWDOODWLRQMUSTFRQIRUPWRWKHMANUFACTURED HOME
CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-80
RUZKHQVXFKVWDQGDUGLVQRWDSSOLFDEOHZLWKAMERICAN
NATIONAL STANDARD FOR MOBILE HOME, ANSI/NFPA NO.
501B.
7KHGU\HUMUSTEHYHQWHGWRWKHRXWGRRUVZLWKWKH
WHUPLQDWLRQVHFXUHO\IDVWHQHGWRWKHPRELOHKRPHVWUXFWXUH
6HHEXHAUST INFORMATIONVHFWLRQ
7KHYHQWMUST NOTEHWHUPLQDWHGEHQHDWKDPRELOHRU
PDQXIDFWXUHGKRPH
7KHYHQWGXFWPDWHULDOMUST BE METAL
'RQRWXVHVKHHWPHWDOVFUHZVRURWKHUIDVWHQLQJGHYLFHV
ZKLFKH[WHQGLQWRWKHLQWHULRURIWKHH[KDXVWYHQW
6HHVHFWLRQIRUHOHFWULFDOFRQQHFWLRQLQIRUPDWLRQ
6
ALCOVE OR CLOSET INSTALLATION
,I\RXUGU\HULVDSSURYHGIRULQVWDOODWLRQLQDQDOFRYHRUFORVHW
LWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN
7KHGU\HUMUSTEHYHQWHGWRWKHRXWGRRUV6HHWKHEXHAUST
INFORMATIONVHFWLRQV
0LQLPXPFOHDUDQFHEHWZHHQGU\HUFDELQHWDQGDGMDFHQWZDOOV
RURWKHUVXUIDFHVLV
LQHLWKHUVLGH
LQIURQWDQGUHDU
0LQLPXPYHUWLFDOVSDFHIURPÀRRUWRRYHUKHDGFDELQHWV
FHLOLQJHWFLVLQ
&ORVHWGRRUVPXVWEHORXYHUHGRURWKHUZLVHYHQWLODWHGDQG
PXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHDHTXDOO\
GLVWULEXWHG,IWKHFORVHWFRQWDLQVERWKDZDVKHUDQGDGU\HU
GRRUVPXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHD
HTXDOO\GLVWULEXWHG
Installation Instructions
6
10
DRYER EXHAUST TO RIGHT, LEFT
OR BOTTOM CABINET
WARNING - BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE
TO DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY. PROTECT YOUR HANDS
AND ARMS FROM SHARP EDGES WHEN
WORKING INSIDE THE CABINET. BE SURE TO
WEAR GLOVES
Note: Only 4” round rigid metal ducting allowed inside
dryer.
TAB LOCATION
Detach and remove the bottom, right or left side knockout
as desired. Remove the screw inside the dryer exhaust duct
and save. Pull the duct out of the dryer.
REMOVE
SCREW
AND SAVE.
REMOVE
DESIRED
KNOCKOUT
(ONE ONLY).
ADDING NEW DUCT
ADDING ELBOW AND DUCT FOR
EXHAUST TO LEFT OR RIGHT SIDE OF
CABINET
3UHDVVHPEOHµHOERZZLWKµGXFW:UDSGXFWWDSH
DURXQGMRLQW
,QVHUWGXFWDVVHPEO\HOERZ¿UVWWKURXJKWKHVLGH
RSHQLQJDQGFRQQHFWWKHHOERZWRWKHGU\HULQWHUQDO
GXFW
CAUTION: Be sure not to pull or damage the
electrical wires inside the dryer when inserting the
duct.
Cut the duct as shown and keep portion A.
9"
AB
FIXING HOLE
Through the rear opening, locate the tab in the middle of
the appliance base. Lift the tab to about 45º using a flat
blade screwdriver.
BEND TAB
UP 45
o
Reconnect the cut portion (A) of the duct to the blower
housing. Make sure that the shortened duct is aligned with
the tab in the base. Use the screw saved previously to secure
the duct in place through the tab on the appliance base.
RIGHT OR
LEFT SIDE
EXHAUST
PORTION "A"
FIXING
HOLE
EXHAUST CAN
BE ADDED TO
LEFT OR RIGHT SIDE
DUCT
TAPE
GARAGE INSTALLATION (IF ALLOWED
BY LOCAL CODES)
'U\HUVLQVWDOOHGLQJDUDJHVPXVWEHHOHYDWHGLQFKHV
FPDERYHWKHÀRRU
9
Installation Instructions
7
$SSO\GXFWWDSHDVVKRZQRQWKHMRLQWEHWZHHQWKH
GU\HULQWHUQDOGXFWDQGWKHHOERZ
ADDING ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
,QVHUWWKHHOERZWKURXJKWKHUHDURSHQLQJDQGFRQQHFW
LWWRWKHGU\HULQWHUQDOGXFW
$SSO\GXFWWDSHRQWKHMRLQWEHWZHHQWKHGU\HULQWHUQDO
GXFWDQGHOERZDVVKRZQRQSDJH
ADDING COVER PLATE TO REAR
OF CABINET (SIDES AND BOTTOM
EXHAUST)
&RQQHFWVWDQGDUGPHWDOHOERZVDQGGXFWVWRFRPSOHWH
WKHH[KDXVWV\VWHP&RYHUEDFNRSHQLQJZLWKDSODWH.LW
:(0DYDLODEOHIURP\RXUORFDOVHUYLFHSURYLGHU
3ODFHGU\HULQ¿QDOORFDWLRQ
WARNING-NEVER LEAVE THE BACK
OPENING WITHOUT THE PLATE. (Kit
WE1M454)
PL ATE
(KIT WE1M454)

CHANGING DIRECTION OF
DOOR OPENING
2SHQWKHGRRUDQGUHPRYHWKH¿OOHUSOXJVRSSRVLWHWKH
KLQJHV:LWKWKHGRRUFRPSOHWHO\RSHQUHPRYHWKH
ERWWRPVFUHZVIURPHDFKKLQJHRQWKHGU\HUIDFH,Q
VHUWWKHVHVFUHZVDERXWKDOIZD\LQWRWKHTOPKROHVIRU
HDFKKLQJHRQWKHRSSRVLWHVLGHZKHUH\RXUHPRYHG
WKH¿OOHUSOXJV$SSO\¿UPSUHVVXUHWRJHWWKHVFUHZ
VWDUWHG
/RRVHQWKHWRSVFUHZVIURPHDFKKLQJHRQWKHGU\HU
IDFHKDOIZD\:LWKRQHKDQGKROGLQJWKHWRSRIWKH
GRRUDQGWKHRWKHUKDQGKROGLQJWKHERWWRPUHPRYH
WKHGRRUIURPWKHGU\HUE\OLIWLQJLWUPDQGOUT
5RWDWHWKHGRRU,QVHUWWKHGRRURQWKHRSSRVLWH
VLGHRIWKHRSHQLQJE\PRYLQJWKHGRRUINDQGDOWN
XQWLOWKHWRSKLQJHDQGWKHERWWRPKLQJHDUHUHVWLQJRQ
WKHWRSVFUHZVLQVHUWHGLQVWHS
5HPRYHWKHUHPDLQLQJVFUHZVIURPWKHVLGHRIWKH
RSHQLQJIURPZKLFKWKHGRRUZDVUHPRYHG:LWKWKHVH
VFUHZVVHFXUHHDFKKLQJHDWWKHERWWRP7LJKWHQWKH
WZRWRSVFUHZVRQHDFKKLQJH5HLQVHUWWKHSODVWLF
SOXJVRQWKHVLGHIURPZKLFKWKHGRRUZDVUHPRYHG
REMOVE THE
BOTTOM SCREW
FROM EACH HINGE
ON THE DRYER FACE
LOOSEN THE TOP SCREWS
FROM EACH HINGE ON
THE DRYER FACE
HALF WAY
MOVE THE DOOR IN AND
DOWN UNTIL THE TOP HINGE
AND THE BOTTOM HINGES ARE
RESTING ON THE TOP SREWS
INSERTED IN STEP 1
SECURE EACH HINGE
AT THE BOTTOM AND
TIGHTEN THE TWO TOP
SCREWS OF EACH HINGE
DUCT
TAPE
CAUTION:
Internal duct joints must be secured with tape,
otherwise they may separate and cause a
safety hazard.
CAUTION:
Internal duct joints must be
secured with tape, otherwise
they may separate and cause
a safety hazard.
Installation Instructions
8
WATER SUPPLY REQUIREMENTS
+RWDQGFROGZDWHUIDXFHWV0867EHLQVWDOOHGZLWKLQ
LQFPRI\RXUZDVKHU·VZDWHULQOHW7KHIDXFHWV
0867EHLQFPJDUGHQKRVHW\SHVRLQOHWKRVHV
FDQEHFRQQHFWHG:DWHUSUHVVXUH0867EHEHWZHHQ
DQGSRXQGVSHUVTXDUHLQFK<RXUZDWHUGHSDUWPHQW
FDQDGYLVH\RXRI\RXUZDWHUSUHVVXUH
NOTE: $ZDWHUVRIWHQHULVUHFRPPHQGHGWRUHGXFH
EXLOGXSRIVFDOHLQVLGHWKHVWHDPJHQHUDWRULIWKHKRPH
ZDWHUVXSSO\LVYHU\KDUG

CONNECTING INLET HOSES
(on some models)
7RSURGXFHVWHDPWKHGU\HUPXVWFRQQHFWWRWKHFROG
ZDWHUVXSSO\6LQFHWKHZDVKHUPXVWDOVRFRQQHFWWRWKH
FROGZDWHUD´<µFRQQHFWRULVLQVHUWHGWRDOORZERWKLQOHW
KRVHVWRPDNHWKDWFRQQHFWLRQDWWKHVDPHWLPH
NOTE:8VHWKHQHZLQOHWKRVHVSURYLGHGQHYHU
XVHROGKRVHV
1.7XUQWKHFROGZDWHUIDXFHWRȺ5HPRYHWKHZDVKHULQOHW
KRVHIURPWKHZDVKHU¿OOYDOYHFRQQHFWRUFROG
2.(QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGVFUHZWKH
IHPDOHFRXSOLQJRIWKHVKRUWKRVHRQWRWKHZDVKHU¿OO
YDOYHFRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
3.$WWDFKWKHIHPDOHHQGRIWKH¶··FRQQHFWRUWRWKH
PDOHFRXSOLQJRIWKHVKRUWKRVH(QVXUHWKHUXEEHUÀDW
ZDVKHULVLQSODFH7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
4.,QVHUWWKH¿OWHUVFUHHQLQWKHFRXSOLQJRIWKHZDVKHU·V
LQOHWKRVH,IDUXEEHUÀDWZDVKHULVDOUHDG\LQSODFH
UHPRYHLWEHIRUHLQVWDOOLQJWKH¿OWHUVFUHHQ$WWDFKWKLV
FRXSOLQJWRRQHPDOHHQGRIWKH¶·<··FRQQHFWRU7LJKWHQ
E\KDQGXQWLO¿UPO\VHDWHG
5.(QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFKWKH
GU\HU·VORQJLQOHWKRVHWRWKHRWKHUPDOHHQGRIWKH¶·<··
FRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
6.(QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFK
WKHRWKHUHQGRIWKHGU\HU·VORQJLQOHWKRVHWRWKH¿OO
YDOYHFRQQHFWRUDWWKHERWWRPRIWKHGU\HUEDFNSDQHO
7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG

CONNECTING INLET HOSES (cont.)
7.8VLQJSOLHUVWLJKWHQDOOWKHFRXSOLQJVZLWKDQDGGLWLRQDO
WZR²WKLUGVWXUQ
NOTE:'RQRWRYHUWLJKWHQ'DPDJHWRWKHFRXSOLQJVPD\
UHVXOW
8.7XUQWKHZDWHUIDXFHWRQ
9.&KHFNIRUOHDNVDURXQGWKH¶·<··FRQQHFWRUIDXFHWDQG
KRVHFRXSOLQJV

SERVICING
WARNING LABEL ALL WIRES
PRIOR TO DISCONNECTING WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION AFTER
SERVICING/INSTALLATION.
)RUVHUYLFLQJSKRQHQXPEHUVIRUUHSODFHPHQWSDUWVDQG
RWKHULQIRUPDWLRQUHIHUWR2ZQHU·V0DQXDORUYLVLWRXU
:HEVLWH
5(*,67(5<2851(:$33/,$1&(725(&(,9($1<
,03257$17352'8&7127,),&$7,216
3OHDVHJRWRZZZGEAppliances.comRUPDLOLQ\RXU
3URGXFW5HJLVWUDWLRQ&DUG
)RUTXHVWLRQVRQLQVWDOODWLRQFDOO86RU
&DQDGD
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

GE GTDP400EMWS Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI