Table-Of-Contents I-2 CI-5450
Page
CHAPTER 3A - G-I-D CONTROLLER (Continued)
Operating Controls & Adjustments ............................................................................3A-2
Initial Startup & Process Tuning.................................................................................3A-3
Routine Shutdowns & Startups...................................................................................3A-5
Using Manual-Automatic Stations..............................................................................3A-5
3A.3 THEORY OF OPERATION ......................................................................................3A-6
One Mode Controllers (Gain Only)............................................................................3A-6
Two Mode Controllers (Gain + Integral)....................................................................3A-8
Three Mode Controllers (Gain + Integral + Derivative).............................................3A-8
Manual-Automatic Station........................................................................................3A-10
3A.4 SERVICE..................................................................................................................3A-10
Troubleshooting........................................................................................................3A-10
Removal of Control Unit ..........................................................................................3A-12
3A.5 CALIBRATION .......................................................................................................3A-13
Test Conditions.........................................................................................................3A-13
Calibration of MV Linkage.......................................................................................3A-13
General Checks for Control Section .........................................................................3A-13
General Check for 1-Mode Type (Gain Only)..........................................................3A-15
General Check for 2 & 3-Mode Types .....................................................................3A-15
Calibration of Control Unit.......................................................................................3A-16
CHAPTER 3B - DIFFERENTIAL GAP CONTROLLER
3B.1 GENERAL DESCRIPTION.......................................................................................3B-1
3B.2 OPERATION..............................................................................................................3B-2
Operating Controls and Adjustments..........................................................................3B-2
Initial Startup ..............................................................................................................3B-3
Routine Shutdowns and Startups................................................................................3B-4
3B.3 CONTROLLER THEORY.........................................................................................3B-4
Setpoint Assembly......................................................................................................3B-4
Control Unit................................................................................................................3B-5
3B.4 SERVICE....................................................................................................................3B-6
Troubleshooting..........................................................................................................3B-7
Removal of Control Unit ............................................................................................3B-7
Calibration of MV Linkage.........................................................................................3B-7
CHAPTER 3C - REMOTE SETPOINT ACTUATOR
3C.1 GENERAL DESCRIPTION.......................................................................................3C-1
3C.2 INSTALLATION NOTES .........................................................................................3C-3
Actuator Enclosure and Cover....................................................................................3C-3
Electrical Conduit Port................................................................................................3C-3
Installation in Hazardous Areas..................................................................................3C-3
3C.3 BOARD CONFIGURATION.....................................................................................3C-5
Using Option Switches ...............................................................................................3C-5
Switch Functions.........................................................................................................3C-6
Analog Actuator Input................................................................................................3C-7
Raise/Lower Actuator Input........................................................................................3C-7
Guard Input.................................................................................................................3C-9
Actuator Output Rate of Change...............................................................................3C-10
Analog Failure Mode (Fail Hold & Fail Zero) .........................................................3C-11
PDM Output..............................................................................................................3C-12
3C.4 FIELD WIRING.......................................................................................................3C-12