2-6
PRODUCT DATA SHEET
SM DLSDCI 3-A.1 GB
2.6 DLS 43 DCI 3PH
Model Indoor Unit
DLS 43 DCI R410A AW
Model Outdoor Unit
AWAU-YAD042-H13
Installation Method of Pipe Flared
Characteristics Units Cooling Heating
Capacity - Nominal (Minimum~ Maximum)
(1)
Btu/hr 42,650(16,000~49,500) 45,000(16,000~54,600)
kW 12.5 (4.5~14.0) 14.0 (4.5~16.0)
Power Input – Nominal (Minimum~Maximum)
(1)
W 3,560 (1,300~4,500) 3,990 (1,450~5,000)
EER (Cooling) or COP (Heating) W/W 3.51 3.51
A B
Power supply V/Ph/Hz 380-400 / 3PH / 50
Rated Current (Nominal) 4.8 4.9
Circuit breaker rating A 3x16
INDOOR
Fan type & quantity Centrifugal x 1
Fan speeds H/M/L RPM 880 / 650 / 560
(2)
H/M/L m3/hr 2025/1450/1250
External static pressure Min-Max Pa 50-100
Sound power level
(3)
H/M/L dB(A) 65 / 60 / 55
Sound pressure level
(4)
H/M/L dB(A) 52 / 49 / 47
Moisture removal l/hr 3.8
Condensate drain tube I.D mm 19
Dimensions WxHxD mm 854x297x816
Weight kg 33
Package dimensions WxHxD mm 1005x345x915
Packaged weight kg 35.5
Units per pallet units 6
Stacking height units 6
OUTDOOR
Refrigerant control EEV
Compressor type, model Twin Rotary DC Inverter
Fan type & quantity Axial x 2
Fan speeds RPM 850-150(continuous)
Max. m
3
/hr 5,700
Sound power level Nom. dB(A) 70
Sound pressure level Nom. dB(A) 58
Dimensions WxHxD mm 900x1250x340
Weight kg 110
Package dimensions WxHxD mm 985x1400x435
Packaged weight kg 121
Units per pallet Units 3
Stacking height units 1 levels
Refrigerant type R410A
Refrigerant charge (standard connecting
tubing length)
kg(7.5m) 3.2
Additional charge (tubing length 30÷70m) gr 40 gr per 1m
Connections
between units
Liquid line In.(mm) 3/8”(9.53)
Suction line In.(mm) 3/4”(19.0)
Max.tubing length m. 70
Max.height difference m. 30
Operation control type Remote control
Heating elements kW BH 70W - optional
Others
(1) Rating conditions in accordance with EN14825 and EN14511 (for ducted units).
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1.0 meter distance from unit.