V-ZUG 64003 Installation guide

Type
Installation guide

V-ZUG 64003: a versatile island hood for your kitchen. This powerful hood offers both extraction and recirculation modes, ensuring efficient removal of cooking fumes and odors. With its sleek design and 120 cm construction width, it seamlessly integrates into modern kitchen environments. The hood features easy-to-remove grease filters for convenient cleaning and maintenance. It operates at a voltage of 230 V and requires a fuse protection of 16 A. The motor housing can be rotated on all four sides for flexible installation options.

V-ZUG 64003: a versatile island hood for your kitchen. This powerful hood offers both extraction and recirculation modes, ensuring efficient removal of cooking fumes and odors. With its sleek design and 120 cm construction width, it seamlessly integrates into modern kitchen environments. The hood features easy-to-remove grease filters for convenient cleaning and maintenance. It operates at a voltage of 230 V and requires a fuse protection of 16 A. The motor housing can be rotated on all four sides for flexible installation options.

Installation instructions
Island hood
Operating mode: Extraction/recirculation
Range hood DSDSR12
J64003113-07
28/10/2020
J64003113-07
1
The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.
Validity
These installation instructions apply to:
64003 (DSDSR12, construction width 120 cm)
64008 (DSDSR12, construction width 120 cm)
General notes
If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances), safe op-
eration is only possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the
appliance.
Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or
windows and in combination with an air-intake/exhaust-air wall box or by other technical means.
If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the minimum dis-
tances (see section «Dimensions») must be adhered to.
Efficient repairs can only be guaranteed if it is possible to uninstall the complete appliance at any time without caus-
ing any damage.
Identification plate
Remove the grease filters. The identification plate is located on the inside of the appliance.
Installation accessories supplied
All fixing elements are contained in the scope of delivery.
Extraction mode
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or
other fuels.
Observe the local fire regulations.
Electrical connections
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.
Use at altitude: Electrical safety is guaranteed up to 2,000 m above sea level.
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The mains plug must not be cut off.
Installation instructions
Island hood
Operating mode: Extraction/recirculation
Range hood DSDSR12
J64003113-07
28/10/2020
J64003113-07
2
Dimensions
ø150
1200
670
A
A
137
318
700
210
X
1170
Cut-out measurements
1178±2
675±2
Distance above hob
Minimum distance X above hob: min. 800 mm
Maximum recommended distance: 1300 mm
Installation
Installation with built-in motor
1. Use the screws S1 to secure the lateral supports A far enough
up that they do not yet lock into place.
S1
2. Create a ceiling cover cut-out that is aligned with the centre of
the hob.
3. Reinforce the two long sides of the ceiling cover with square
timber B. The total combined height of the wood and the ceiling
cover must measure between 60mm and 75mm.
The motor housing D can be rotated on all four sides.
B
D
J
J
A
A
4. Position the ceiling hood as close as possible to the ceiling.
Connect the mains connection and the exhaust air pipe.
60–75
B
A
5. Push the ceiling hood into the cut-out until the lateral supports
A lock into place.
6. Screw the four screws S1 into the hood until the ceiling hood
comes into contact with the ceiling.
7. Carry out function test.
Installation instructions
Island hood
Operating mode: Extraction/recirculation
Range hood DSDSR12
J64003113-07
28/10/2020
J64003113-07
3
Installation with external motor
Accessory set H43403 is required (not included in scope of delivery).
1. Use the screws S1 to secure the lateral supports A far enough
up that they do not yet lock into place.
J
J
A
2. Create a ceiling cover cut-out that is aligned with the centre of
the hob.
B
D
J
J
A
A
3. Reinforce the two long sides of the ceiling cover with square
timber B. The total combined height of the wood and the ceiling
cover must measure between 60mm and 75mm.
4. Disassemble the motor housing D.
5. Disconnect the cable C that leads to the motor directly from the
motor.
A
G
E
F
S2
S2
5
C
C
F
64003
64008
*
*
*
*
M
3
~
F
M
3
~
6. Screw the locking plate E to the hood, pull the long cable F
through the hood cut-out (it may be necessary here to remove
the perforated sheet) and plug it into the existing motor cable
C*. The earthing for the motor cable C and the long cable F
must both be connected in the designated place (see for
earthing) on the appliance. If the air is extracted in an upwards
direction, then the round perforation in the locking plate E must
be removed. (*) Depending on the model.
7. Connect the exhaust duct 5 to the connection tube G. The con-
necting lead can be mounted on all four sides.
8. If the air is extracted to the side, remove the corresponding lat-
eral perforation J on the hood.
9. Connect the mains cable.
10. Push the ceiling range hood into the cut-out until the lateral
supports A lock into place.
11. Screw the four screws S1 into the hood until the ceiling range
hood comes into contact with the ceiling.
12. Remove the metal grease filters. Screw together the connec-
tion tube G from the inside using four screws S2.
Installation instructions
Island hood
Operating mode: Extraction/recirculation
Range hood DSDSR12
J64003113-07
28/10/2020
J64003113-07
4
13. Insert the long cable through the suction part of the housing H
and connect to the motor.
14. Screw the suction part of the housing H to the motor housing
D, taking care to ensure correct alignment.
15. Connect the ceiling range hood to the external motor unit 8 us-
ing a flat channel 5, transition piece 6 (square to round) and
round pipe 7.
Connection variants for ceiling range hoods
8
9
10
7
11 Recirculation box optional
11
5
6
7
8
9
10
10
16. Connect the exhaust air side 9 of the external motor unit 8 to
the exhaust air pipe 10.
17. Carry out function test.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

V-ZUG 64003 Installation guide

Type
Installation guide

V-ZUG 64003: a versatile island hood for your kitchen. This powerful hood offers both extraction and recirculation modes, ensuring efficient removal of cooking fumes and odors. With its sleek design and 120 cm construction width, it seamlessly integrates into modern kitchen environments. The hood features easy-to-remove grease filters for convenient cleaning and maintenance. It operates at a voltage of 230 V and requires a fuse protection of 16 A. The motor housing can be rotated on all four sides for flexible installation options.