V-ZUG DSDR12 Installation guide

Type
Installation guide
Installation instructions
Ceiling hood
Operating mode: extracted air
Range hood DSDSR12
J64003113-R03
28/01/2016
1
The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.
Validity
These installation instructions apply to:
64003 (DSDSR12, construction width 120 cm)
General notes
If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances),
safe operation is only possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at
the location of the appliance.
Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in
doors or windows and in combination with an air-intake/exhaust-air wall box or by other technical means.
If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the min-
imum distances (see section «Dimensions») must be adhered to.
Efficient repairs can only be guaranteed if it is possible to uninstall the complete appliance at any time without
causing any damage.
Identification plate
Remove the grease filters. The identification plate is located on the inside of the appliance.
Installation accessories supplied
All fixing elements are contained in the scope of delivery.
Extraction mode
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burn-
ing gas or other fuels.
Observe the local fire regulations.
Electrical connections
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and
standards for low-voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to spe-
cifications. An all-pole mains isolating device with 3 mm contact opening should be provided in the house wir-
ing system. Switches, plug and socket devices, circuit breakers and fusible cut-outs which are accessible after
installation and which have all-poles switching are permissible as isolating devices. Effective earthing and sep-
arately installed neutral and earth conductors ensure safe and fault-free operation. After installation, live parts
and cables with basic insulation must not be accessible. Check old installations.
The appliance is designed for use up to a max. altitude of 2000 m above sea level.
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
The mains plug must not be cut off.
Installation instructions
Ceiling hood
Operating mode: extracted air
Range hood DSDSR12
J64003113-R03
28/01/2016
2
Dimensions
Ø 150
1200
1170
318
670
700
210
A
133
A
X
Cut-out measurements
1178±2
675±2
Distance above hob
Minimum distance X above hob: min. 800 mm
Maximum recommended distance: 1300 mm
Installation
Installation with built-in motor
1.
Use the screws S1 to secure the lateral supports A far
enough up that they do not yet lock into place.
S1
2. Create a ceiling cover cut-out that is aligned with the
centre of the hob.
3. Reinforce the two long sides of the ceiling cover with
square timber B. The total combined height of the wood
and the ceiling cover must measure between 60mm
and 75mm.
The motor housing D can be rotated on all four sides.
B
D
J J
A
A
4. Position the ceiling hood as close as possible to the
ceiling. Connect the mains connection and the exhaust
air pipe.
60 – 75
B
A
5. Push the ceiling hood into the cut-out until the lateral
supports A lock into place.
6.
Screw the four screws S1 into the hood until the ceiling
hood comes into contact with the ceiling.
7. Carry out function test.
Installation instructions
Ceiling hood
Operating mode: extracted air
Range hood DSDSR12
J64003113-R03
28/01/2016
3
Installation with external motor
Accessories set H43403 is required (not in scope of delivery).
1.
Screw lateral supports A upwards as far as possible be-
fore they fold back in using screws S1.
J
J
A
2. Make the ceiling cut-out, aligned with the middle of the
hob.
B
D
J J
A
A
3. Reinforce the ceiling along the two long sides with rect-
angular wooden blocks B. Total height including wood
and ceiling must be between 60mm and 75mm.
4.
Unplug motor cable C leading to the motor directly at
the motor.
A
G
E
F
S2
S2
5
C
F
C
M
3~
5.
Take off the motor housing D.
6.
Screw locking plate E to the hood and then pull long
cable F through the cut-out in the hood (where neces-
sary, detach the perforated plate) and plug into existing
motor cable C. If the air outlet is directed upwards, the
round perforation in locking plate E must be detached.
7.
Connect exhaust duct 5 to connecting piece G. The
connecting lead can be installed on all four sides.
8. If the air outlet is at the side, detach relevant lateral per-
foration J in the hood.
9. Connect mains plug to mains socket.
10. Slide the ceiling hood into the cut-out until the lateral
supports A engage.
11.
Screw the four screws S1 into the hood until the ceiling
hood rests on the ceiling.
12.
Remove the grease filters. Fasten connecting piece G
from the inside with four screws S2.
Installation instructions
Ceiling hood
Operating mode: extracted air
Range hood DSDSR12
J64003113-R03
28/01/2016
4
13.
Pass the long cable through air intake housing half H
and plug into the motor.
D
H
14.
Screw air intake housing half H to motor housing D.
Make sure they are correctly aligned.
15.
Connect the ceiling range hood to external motor unit 8
by means of flat channel 5, transition piece 6 (from an-
gular to round) and round pipe 7 .
Connection variants for ceiling range hoods
11 Optional recirculation
box
11
5
6
7
8 9
10
10
16.
Connect exhaust air side 9 of external motor unit 8 to
exhaust air pipe 10.
17. Carry out function test.