ADC Campus-REX RS Interface Card User manual

Category
PC/workstation barebones
Type
User manual

This manual is also suitable for

USER MANUAL
Campus-REX RS Interface Card
Catalog Number: CAD1069I5 Issue 5
1
0
B
a
s
e
T
E
T
H
E
R
N
E
T
B
R
I
D
G
E
LINK
CAD1069i5.book Page i Thursday, May 30, 2002 7:32 AM
ii Campus-REX RS Interface Card User Manual
Copyright
April, 2001
© 2001 ADC DSL Systems, Inc. All rights reserved.
Trademark Information
ADC and ADC Telecommunications are registered trademarks of ADC
Telecommunications, Inc.
Avidia is a registered trademark of ADC DSL Systems, Inc.
No right, license, or interest to such trademarks is granted hereunder, and you agree
that you shall assert no such right, license, or interest with respect to such trademarks.
All other product names mentioned in this document are used for identification
purposes only and may be trademarks or registered trademarks of their respective
companies.
Information contained in this document is company private to ADC DSL Systems, Inc.,
and shall not be modified, used, copied, reproduced or disclosed in whole or in part
without the written consent of ADC.
Information furnished by ADC DSL Systems, Inc. is believed to be accurate and
reliable. However, no responsibility is assumed by ADC DSL Systems, Inc. for its use;
nor for any infringement of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or
patent rights of ADC DSL Systems, Inc. ADC DSL Systems, Inc. reserves the right to
change specifications at any time without notice.
Disclaimer of Liability
Information contained in this document is company private to ADC DSL Systems, Inc.,
and shall not be modified, used, copied, reproduced or disclosed in whole or in part
without the written consent of ADC.
Contents herein are current as of the date of publication. ADC reserves the right to
change the contents without prior notice. In no event shall ADC be liable for any
damages resulting from loss of data, loss of use, or loss of profits, and ADC further
CAD1069i5.book Page ii Thursday, May 30, 2002 7:32 AM
FCC Notice
Campus-REX RS Interface Card User Manual iii
FCC NOTICE
This unit complies with the limits for a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the situation by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Consult the dealer or an experienced radio or television technician
for help.
Any changes or modifications not expressly approved by the grantee of this
device voids the user’s authority to operate the equipment.
CAD1069i5.book Page iii Thursday, May 30, 2002 7:32 AM
Using This Manual
iv Campus-REX RS Interface Card User Manual
USING THIS MANUAL
This manual documents the Campus-REX
®
RS Interface Card (part number
150-1175-51). It includes information on how to:
install the card in either a Campus-RS
Desktop Unit (150-1158-01,
150-1158-02, 150-1158-51, or 150-1158-52) or Campus-Star
®
chassis
(150-1220-01, 150-1220-02, or 150-1220-51)
configure the Campus-REX to operate as a bridge or a router
monitor the Campus-REX
contact ADC for assistance.
DOCUMENT CONVENTIONS
Two types of messages, identified by icons, appear in the text.
This manual uses the following conventions:
This font indicates text that appears on the LCD or terminal.
Keycaps, such as , indicate keys that you press on a terminal
keyboard.
Key names in bold font indicate buttons on the desktop unit or line unit
that you press.
For a list of abbreviations used in this manual, see “Abbreviations” on
page B-1.
Notes contain information about special circumstances.
Cautions indicate the possibility of personal injury or
equipment damage.
ESC
CAD1069i5.book Page iv Thursday, May 30, 2002 7:32 AM
Unpack and Inspect the Shipment
Campus-REX RS Interface Card User Manual v
UNPACK AND INSPECT THE SHIPMENT
Upon receiving the Campus-REX RS Interface Card:
1 Unpack the card and inspect it for signs of damage. If it has been
damaged in transit, report the extent of the damage to the transportation
company and to your sales representative immediately. Order
replacement equipment if necessary.
2 Compare the contents of the package against the packing list to ensure a
complete and accurate shipment. If the shipment is incomplete or
incorrect, contact ADC as described in “Contacting ADC” on page D-1.
If you need to store the unit for several days or more before installing it, return
it to the original packaging.
CAD1069i5.book Page v Thursday, May 30, 2002 7:32 AM
Unpack and Inspect the Shipment
vi Campus-REX RS Interface Card User Manual
CAD1069i5.book Page vi Thursday, May 30, 2002 7:32 AM
Table of Contents
Campus-REX RS Interface Card User Manual vii
TABLE OF CONTENTS
Chapter 1: About the Product_________________________1-1
Product Features..................................................................................1-2
Compatibility with Earlier Campus Products......................................1-2
Compatibility with Campus-RS Products ...........................................1-4
Establishing an HDSL Link ................................................................1-5
Application..........................................................................................1-6
Point-to-Point LAN Extension..............................................1-6
LAN Connections Over a WAN...........................................1-7
LAN Extension in a Routed Environment............................1-8
Chapter 2: Installing the Campus-REX RS
Interface Card____________________________2-1
Install the Card....................................................................................2-1
Installing into a Campus-RS Desktop Unit...........................2-2
Installing into a Campus-Star Chassis ..................................2-3
Connect the Ethernet Line...................................................................2-4
Choosing the Cable...............................................................2-4
Connecting the Cable............................................................2-6
Power Up and Check the Ethernet Line..............................................2-7
Chapter 3: Set Up the Campus-REX System_____________3-1
Set Up an ASCII Terminal..................................................................3-2
Connecting the ASCII Terminal to the Campus Unit...........3-3
Logging Onto the Terminal ..................................................3-5
Set the HDSL Operating Mode...........................................................3-7
Using the LCD......................................................................3-8
CAD1069i5.book Page vii Thursday, May 30, 2002 7:32 AM
Table of Contents
viii Campus-REX RS Interface Card User Manual
Standard HDSL Mode.............................................3-8
Extended HDSL Mode............................................3-9
AutoSync HDSL Mode.........................................3-10
Using an ASCII Terminal....................................................3-11
Standard HDSL Mode...........................................3-12
Extended HDSL Mode..........................................3-13
AutoSync HDSL Mode.........................................3-16
Configure the Campus-REX as a Bridge or Router...........................3-19
Configuring as a Bridge ......................................................3-19
From the LCD.......................................................3-20
From an ASCII Terminal......................................3-21
Configuring as a Router ......................................................3-23
Entering Port Addresses........................................3-26
Setting Up the IP Static Routing Table.................3-27
Set the Timing Source........................................................................3-29
Using the LCD.....................................................................3-30
Using an ASCII Terminal....................................................3-30
Chapter 4: Configuring and Monitoring
through the LCD _________________________ 4-1
Navigating the LCD Menus.................................................................4-2
Restoring the System to Default Values..............................................4-3
Configuring the Campus-REX as a Master or Slave Unit...................4-4
CAD1069i5.book Page viii Thursday, May 30, 2002 7:32 AM
Table of Contents
Campus-REX RS Interface Card User Manual ix
Viewing and Configuring Alarms.......................................................4-5
HDSL Alarms .......................................................................4-5
Viewing Current Alarms ........................................4-5
Configuring Alarm Thresholds...............................4-6
Viewing 24-Hour HDSL Alarm History................4-7
AutoSync Alarms..................................................................4-7
Viewing Current Alarms ........................................4-8
Configuring the Alarm ...........................................4-8
Local Alarms.........................................................................4-8
Viewing Current Alarms ........................................4-8
Configuring the Alarm ...........................................4-9
Remote Alarms .....................................................................4-9
Viewing Current Alarms ........................................4-9
Configuring the Alarm .........................................4-10
Configuring Loopbacks.....................................................................4-10
Initiating a Loopback..........................................................4-11
Clearing a Loopback...........................................................4-11
Setting the Loopback Timeout............................................4-12
Viewing System Information ............................................................4-12
Viewing Status Information ..............................................................4-13
Ethernet Information...........................................................4-13
HDSL Margin .....................................................................4-14
Port Statistics ......................................................................4-14
Chapter 5: Configuring with an ASCII Terminal_________5-1
Setting Up and Logging On to an ASCII Terminal.............................5-2
Logging Onto a Remote Campus Unit................................................5-3
Logging Off of a Campus Unit............................................................5-3
CAD1069i5.book Page ix Thursday, May 30, 2002 7:32 AM
Table of Contents
x Campus-REX RS Interface Card User Manual
Using the Terminal Menus ..................................................................5-4
Returning Configuration Options to Default Values...........................5-5
Configuring the Campus-REX for SNMP Management.....................5-6
Entering Required SNMP Parameters...................................5-8
Enabling Authentication Error Trap Generation...................5-9
Configuring Startup Parameters.........................................................5-10
Configuring the Campus-REX as a Master or Slave Unit.................5-12
Configuring Alarms...........................................................................5-15
Entering System Information.............................................................5-17
Setting the Time and Date...................................................5-18
Setting a Password...............................................................5-19
Identifying the Unit and Circuit ..........................................5-19
Configuring Loopbacks.....................................................................5-20
Initiating a Loopback...........................................................5-22
Clearing a Loopback ...........................................................5-22
Setting the Loopback Timeout ............................................5-23
Updating the Campus-REX Firmware...............................................5-24
Chapter 6: Monitoring with an ASCII Terminal_________ 6-1
Monitoring HDSL Performance ..........................................................6-2
24-Hour Performance History...............................................6-4
Seven-Day Performance History...........................................6-5
Viewing Local Alarm History.............................................................6-6
Viewing Ethernet Statistics..................................................................6-8
Viewing Product Information............................................................6-10
CAD1069i5.book Page x Thursday, May 30, 2002 7:32 AM
Table of Contents
Campus-REX RS Interface Card User Manual xi
Chapter 7: Internetworking and Management
Overview ________________________________7-1
MAC-Level Bridging and Spanning Tree Protocol ............................7-2
MAC-Level Bridging............................................................7-2
Spanning Tree.......................................................................7-2
Static IP Routing .................................................................................7-4
Campus-REX IP Addresses..................................................7-9
Management Protocols......................................................................7-11
SNMP..................................................................................7-11
Campus-REX SNMP Agent ...............................................7-12
MIB and Trap Support........................................................7-13
BOOTP ...............................................................................7-14
Encapsulation Protocols....................................................................7-15
Appendix A: Technical Reference _____________________ A-1
Specifications .....................................................................................A-1
Default Settings..................................................................................A-2
LCD Menu Reference ........................................................................A-3
ASCII Terminal Menu Reference ......................................................A-5
Appendix B: Abbreviations __________________________ B-1
Appendix C: The Documentation Set __________________ C-1
CAD1069i5.book Page xi Thursday, May 30, 2002 7:32 AM
Table of Contents
xii Campus-REX RS Interface Card User Manual
Appendix D: Contacting ADC ________________________D-1
Product Support ..................................................................................D-1
Advance Replacement ........................................................................D-2
Billing .................................................................................................D-2
Index _____________________________________________E-1
CAD1069i5.book Page xii Thursday, May 30, 2002 7:32 AM
Campus-REX RS Interface Card User Manual 1-1
1
ABOUT THE PRODUCT
The Campus
®
Remote Ethernet eXpress (Campus-REX) RS Interface Card
installs into a:
Campus-Star
®
chassis, along with a Campus-RS
(Rate Selectable)
Line Unit
Standalone Campus-RS Desktop Unit
This comprises half of a High-bit-rate Digital Subscriber Line (HDSL)
transmission system. When connected to another Campus-RS, Campus-T1
®
,
Campus-768
®
, or Campus-E1
®
Desktop Unit or Line Unit, the Campus-RS
system can transport digitized voice, data, and video signals over existing
copper wire at a number of different HDSL rates.
The Campus HDSL system provides a connection between geographically
distributed Ethernet Local Area Networks (LANs) in a campus environment.
To provide the connection, the Campus-REX performs transparent 802.3
MAC bridging or static IP routing over an HDSL line. You can use existing
telephone-grade copper wiring as the HDSL transmission medium.
This version of the Campus-REX must be installed in a
Campus-RS or Campus-HRS Desktop Unit or with a
Campus-RS or Campus-HRS Line Unit. It cannot be installed
in an older Campus Desktop Unit or with an older Campus
Line Unit.
CAD1069i5.book Page 1 Thursday, May 30, 2002 7:32 AM
About the Product
1-2 Campus-REX RS Interface Card User Manual
PRODUCT FEATURES
The Campus-REX provides complete main bridging tasks such as dynamic
address learning, forwarding, filtering, and hashing/buffer management.
Other features include:
embedded Simple Network Management Protocol (SNMP) agent
IEEE 802.1d transparent MAC level bridging with Spanning Tree
protocol support
static IP Routing
BOOTP for configuration of IP parameters
HDLC (High-level Data Link Control) or PPP (Point-to-Point Protocol)
frame encapsulation options
10BASE-T port for connection to an 802.3 LAN
console port for maintenance and management
COMPATIBILITY WITH EARLIER CAMPUS
P
RODUCTS
When mated with a Campus-RS Desktop Unit or Campus-RS Line Unit, the
Campus-REX RS Interface Card is compatible, over the HDSL link, with
earlier versions of Campus products, such as the Campus-T1, Campus-E1,
and Campus-768, as shown in the following illustration. Campus-RS units are
not currently compatible with Campus-384 products.
Campus-REX RS
Interface card
Campus-REX T1,
Campus-REX E1, or
Campus-REX 768
Campus-RS
Campus-T1, Campus-E1 or
Campus-768
HDSL
CAD1069i5.book Page 2 Thursday, May 30, 2002 7:32 AM
About the Product
Campus-REX RS Interface Card User Manual 1-3
All earlier versions of Campus products are manufactured to operate at a
single HDSL transmission rate, while the Campus-RS transmission rate is
user-selectable. To support compatibility with earlier Campus Products, the
following configuration options must be set on the Campus-REX:
Set the HDSL Operating Mode to Standard Mode.
Set the Standard Mode HDSL Rate to T1, E1, or 768, to match the rate
of the earlier product.
If a Campus-RS unit is connected over an HDSL link to an earlier Campus
product, and if either unit has the HDSL Transceiver (XCVR) Mode set to
AUTO, the HDSL link may not operate properly.
When operating the Campus-RS product with an earlier version of the
Campus products, to avoid any problems with link startup or operation, it is
recommended that the Transceiver Mode be set as follows:
Campus-RS = MASTER
Campus E1/T1/768 = SLAVE
If one or both units are already set to AUTO and the HDSL link is active,
disconnect the HDSL link, change the settings as recommended, and
reconnect the link. This will assure the link integrity on any subsequent
startups.
For information on setting these options, see “Set the HDSL Operating
Mode” on page 3-7.
This situation does not apply to a circuit with two Campus-RS
units. You may leave the units set to their default setting of
AUTO, and they will operate properly.
CAD1069i5.book Page 3 Thursday, May 30, 2002 7:32 AM
About the Product
1-4 Campus-REX RS Interface Card User Manual
COMPATIBILITY WITH CAMPUS-RS PRODUCTS
The Campus-REX RS Interface Card is also compatible, over the HDSL link,
with another Campus-RS unit, as shown in the following illustration.
When connecting to another Campus-RS Desktop Unit or Line Unit,
Standard Mode is still supported, providing access to HDSL transmission
rates of T1, E1 and 768 kbps. In addition, the Campus-RS system can be
configured to support an extended set of HDSL transmission rates, over either
one or two HDSL loops.
To support these additional transmission rates, set the following options on
the Campus-REX:
Set the HDSL Operating Mode to Extended Mode or AutoSync Mode.
Set the Extended Mode Loop Configuration to 1 Loop or 2 Loops,
depending on the physical layout of your HDSL network.
Set the Extended Mode HDSL Rate to the desired setting.
Campus-RS
Interface card
Campus-RS Campus-RS
HDSL
Campus-REX RS
Interface card
CAD1069i5.book Page 4 Thursday, May 30, 2002 7:32 AM
About the Product
Campus-REX RS Interface Card User Manual 1-5
The range of rates available for the HDSL Rate depends on the setting of
the Extended Mode Loop Configuration:
1 Loop HDSL Rate settings are between 128 kbps and 1.152 Mbps,
in 64 kbps increments
2 Loop HDSL Rate settings are between 256 kbps and 2.304 Mbps,
in 128 kbps increments
For information on setting these options, see “Set the HDSL Operating
Mode” on page 3-7.
ESTABLISHING AN HDSL LINK
Before an HDSL link can be established in Standard or Extended Mode, the
HDSL parameters for both the local and remote units must be set identically.
Using AutoSync Mode allows one unit to determine the HDSL parameters.
In AutoSync Mode, one unit is configured as a master and the other as a slave.
Upon startup, the HDSL parameters of the master unit are used to establish
the HDSL link. No further configuration of the slave unit is required.
If the remote unit is not configured as an AutoSync slave, an AutoSync
connection will not be established and the system generates an AutoSync
minor alarm. After several failed attempts, the master enters Fallback Mode
and attempts to establish a normal HDSL link with the same HDSL
parameters. If this is unsuccessful, for example, if the slave unit is configured
to a different HDSL Rate, the master unit reverts to attempting to establish an
AutoSync connection.
Not all of these modes and rates are available if the remote
Campus-RS system does not support them. Refer to the
remote interface card User Manual to see the HDSL modes
and rates supported by the card.
CAD1069i5.book Page 5 Thursday, May 30, 2002 7:32 AM
About the Product
1-6 Campus-REX RS Interface Card User Manual
APPLICATION
When installed in a Campus-RS Desktop Unit or Campus-Star chassis, the
Campus-REX functions as a remote bridge or static IP router.
You can use the Campus-REX to extend subnetworks to remote sites within
a campus. Or, for sites separated by greater distances, you can use the
Campus-REX to connect them through a public T1/E1 Wide Area Network
(WAN). See “Point-to-Point LAN Extension” and “LAN Connections Over
a WAN” on page 1-7 for more information.
Campus-REX software provides complete main bridging tasks of learning,
forwarding, filtering, and hashing/buffer management, 802.1d Spanning Tree
protocol, 802.3 drivers, packet sequencing, segmentation and reassembly,
and other local tasks. The Campus-REX is specifically designed for
10BASE-T LANs that use unshielded twisted pair (UTP) segments with
reach of more than 100 meters and that require low-cost, high performance
connectivity.
The Campus-REX performs full-bandwidth filtering on the 10BASE-T port,
and forwarding at the selected transmission rate.
Point-to-Point LAN Extension
As organizations move or change, LANs also evolve and may become
fragmented or physically separated. The Campus-REX provides a lower-cost
alternative to other LAN-extension solutions. The Campus-REX provides a
built-in 10BASE-T LAN interface that eliminates the need for other
internetworking devices while providing 30 times the performance of other
sub-rate wireless connectivity options, as shown in the following figure.
CAD1069i5.book Page 6 Thursday, May 30, 2002 7:32 AM
About the Product
Campus-REX RS Interface Card User Manual 1-7
LAN Connections Over a WAN
When LANs are distributed over a large physical area (such as within a
metropolitan area) or cabling is not available between sites, you can lease
appropriate unloaded copper pairs from a local carrier for LAN connectivity.
For transport over public networks, you can connect the public T1 network
(DSX-1 signal) to the LAN through Desktop Units with CSU/DSX-1
interface cards and the Campus-REX in a Desktop Unit. This application, as
shown in the following figure, simplifies access to public high-speed WANs
for LAN connectivity to remote sites.
Campus-REX
Campus-REX
Campus-REX
Campus-REX
Campus-REX
Campus-REX
LAN
LAN
LAN
LAN
LAN
LAN
Campus-Star
Campus-T1
Campus-RS
Campus-RS
10BASE-T
10BASE-T
10BASE-T
10BASE-T
10BASE-T
10BASE-T
DSX-1
DSX-1
PublicT1
Network
WAN
CAD1069i5.book Page 7 Thursday, May 30, 2002 7:32 AM
About the Product
1-8 Campus-REX RS Interface Card User Manual
LAN Extension in a Routed Environment
The Campus-REX, set for bridging over PPP, can extend LAN access to a
centralized router. This application, as shown in the following figure, requires
two settings for the remote Campus-REX units:
set the Bridge/Router mode to Bridge
set the Encapsulation to PPP
In this application, the router ports must be configured for
bridging with PPP encapsulation.
Campus-RS Campus-REX
Campus-REX
Campus-REX
Campus-REX
Campus-REX
Campus-REX
Campus-RS
LAN
LAN
LAN
LAN
LAN
LAN
Campus-Star
Campus-T1
10BASE-T
10BASE-T
10BASE-T
10BASE-T
10BASE-T
10BASE-T
V.35
External
network
connections
V.35
V.35
Router
CAD1069i5.book Page 8 Thursday, May 30, 2002 7:32 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148