  • Hello! I am an AI chatbot trained to assist you with the Dacor PRV46S Combined Configuration RGC-SGM Cooktop - Slim Raised Vent?? PDF [0.5 MB]. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • How much space is required behind the raised vent?
    How far from the mounting surface should combustibles be located below the cooktop chassis?
    What is the minimum countertop overhang required behind the cutout?
    How far should the side of the cooktop be from combustible side walls?
    What are the cutout dimensions for the Dacor PRV46S?
PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
CI.14
Stiffener
Cabinet face
Countertop
Floor
3/8” Min. (10 mm) space
behind raised vent
chassis to clear stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
SGM Series Cooktop
RGC/SGM Series Drop-In Gas Cooktop
with ERV/PRV Series Raised Vent
COMBINATION INSTALLATIONS
Document # PGCI-008 Revised 05/07/09 Page 1/2
WARNING
Observe all governing codes and ordinances during ◊
planning and installation. Contact your local building
department for further information.
All appliances must be installed in accordance with the ◊
accompanying installation instructions.
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted
Cutout Dimensions
Side View - RGC/SGM Series Cooktop with
ERV/PRV Series Raised Vent
IMPORTANT: Be careful to use the correct cutout diagram (on page 2/2) to determine the countertop dimensions. Carefully double check
all dimensions against the table below and the correct diagram before cutting the countertop.
* Total cutout depth, accommodates both the cooktop and raised vent
** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D).
RGC or SGM series cooktop
Countertop Dimensions
Installation Type Cutout
Diagram
C (minimum) D E F G H
RGC/SGM304 with
ERV30 or PRV30
Figure 1
(Square)
3/8”
(10 mm)
22 1/2” *
(572 mm)
27 3/4”
(686 mm)
NA NA NA
RGC/SGM365 with
ERV36 or PRV36
Figure 1
(Square)
3/8”
(10 mm)
22 1/2” *
(572 mm)
33 5/8”
(854 mm)
NA NA NA
RGC/SGM466 with
PRV46
Figure 2
(Notched)
3/8”
(10 mm)
22 1/2” *
(572 mm)
44 3/4”
(1137 mm)
43 1/2”
(1105 mm)
5/8”
(16 mm)
2 5/8” **
(67 mm)
PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
CI.15
RGC/SGM Series Drop-In Gas Cooktop
with ERV/PRV Series Raised Vent
COMBINATION INSTALLATIONS
All tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated
Document # PGCI-008 Revised 05/07/09 Page 2/2
4 1/4" (108 mm) Min.
from mounting surface to
combustibles below
cooktop chassis
E
C
D
7 1/2" (191 mm) Min.
to combustible
side wall above
countertop
(both sides)
Vertical
combustible
surface
Rear
wall
1 7/8" Min.
(48 mm)
E
C
D
H
H
G
F
7 1/2" (191 mm) Min.
to combustible
side wall above
countertop
(both sides)
Vertical
combustible
surface
Rear
wall
1 7/8" Min.
(48 mm)
4 1/4" (108 mm) Min. from
mounting surface to combustibles
below cooktop chassis
Figure 1 - Square Countertop Cutout Diagram
Figure 2 - Notched Countertop Cutout Diagram
(SGM466 only)
/