NICOR T4A User manual

  • I've reviewed the provided installation instructions for the T4A LED Troffer. This guide details the necessary steps for installing the fixture, including safety precautions, tools required, wiring instructions, and dimming system connections. I'm here to help answer any specific questions you may have about these instructions.
  • Who should perform the installation?
    What should be done before installing or servicing the fixture?
    What supply conductors are required?
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com July 7, 2017 3:36 PM rev 1.0
T4A LED TROFFER
INSTALLATION INSTRUCTIONS
Carefully unpack the xture from its packaging. Inspect product
for defects due to shipping.
Locate desired positioning for xture in ceiling grid. Remove ceiling
tiles if necessary.
12
4Place xture into the T-grid
ceiling panel. Secure to
structure and/or grid per
state and local codes.
Turn o power to appropriate circuit at
the breaker panel.
3
What’s In The Box
One (1) T4A LED Troer Wire Nuts
Tools Needed
This LED Troer requires very few tools for installation.
A drill or a screwdriver and a pair of wirecutter.
The installation must only be performed by a licensed electrician.
To prevent death, injury or damage to property, this product must be installed in accordance to National Electrical Code (NFPA70) in the US
or Canadian Electrical Code (CSA 22.1) in Canada.
Disconnect power before installing the product or servicing it.
Wait until xture has cooled down before installing or servicing the xture.
MIN. 90°C SUPPLY CONDUCTORS
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com July 7, 2017 3:36 PM rev 1.0
6
78
Connect wiring as shown. Grey and purple wiring are for 0-10V
dimming systems. Cap o if not used.
Turn power on and verify that the panel is lit.
Reattach cover of junction box and secure with (2) two screws.
Remove cover from power supply juntion box by removing (2)
two screws (do not discard).
5
Luminaire
LED Driver
White
Black
Com
Line
GND
Junction Box
RedRed
BlackBlack
*
*Cap o if not used
*
Grey
Purple
1-10V (-)
1-10V (+)
/