AIR CARE SEMINAR TRAINING
Sullair Air Care Seminars are courses that provide hands-on instruction for the proper operation, maintenance,
and servicing of Sullair products. Individual seminars on Industrial compressors and compressor electrical
systems are offered at regular intervals throughout the year at Sullair’s corporate headquarters training facility
located at Michigan City, Indiana.
Instruction includes training on the function and installation of Sullair service parts, troubleshooting common
faults and malfunctions, and actual equipment operation. These seminars are recommended for maintenance,
contractor maintenance, and service personnel.
For detailed course outlines, schedule, and cost information contact:
SULLAIR CUSTOMER CARE TRAINING DEPARTMENT
1-888-SULLAIR or
219-879-5451 (ext. 5623)
www.sullair.com
- Or Write -
Sullair Corporation
3700 E. Michigan Blvd.
Michigan City, IN 46360
Attn: Service Training Department.
TABLE OF CONTENTS
SECTION 1—SAFETY
7 1.1 GENERAL
7 1.2 PERSONAL PROTECTIVE EQUIPMENT
7 1.3 PRESSURE RELEASE
8 1.4 FIRE AND EXPLOSION
8 1.5 MOVING PARTS
9 1.6 HOT SURFACES, SHARP EDGES AND SHARP CORNERS
9 1.7 TOXIC AND IRRITATING SUBSTANCES
10 1.8 ELECTRICAL SHOCK
10 1.9 LIFTING
11 1.10 ENTRAPMENT
SECTION 2—DESCRIPTION
13 2.1 INTRODUCTION
13 2.2 DESCRIPTION OF COMPONENTS
13 2.3 ENCAPSULATED COMPRESSOR SYSTEM, FUNCTIONAL DESCRIP-
TION
16 2.4 COMPRESSOR COOLING SYSTEM FUNCTIONAL DESCRIPTION
16 2.5 AIR INLET SYSTEM, FUNCTIONAL DESCRIPTION
17 2.6 CONTROL SYSTEM, FUNCTIONAL DESCRIPTION
17 2.7 INSTRUMENTATION, FUNCTIONAL DESCRIPTION
SECTION 3—SPECIFICATIONS
19 3.1 TABLE OF SPECIFICATIONS
20 3.2 COMPRESSOR LUBRICATION GUIDE
21 3.3 LUBRICATION GUIDE - 24KT COMPRESSORS
22 3.4 LUBRICATION GUIDE - OPTIONAL FLUID
24 3.5 IDENTIFICATION, ES-6 STANDARD WITHOUT ENCLOSURE
26 3.6 IDENTIFICATION, ES-6 STANDARD WITH ENCLOSURE
28 3.7 IDENTIFICATION, ES-6 OPEN TANK MOUNT (80 GALLON)
30 3.8 IDENTIFICATION, ES-6 ENCLOSED TANK MOUNT (80 GALLONS)
32 3.9 IDENTIFICATION, ES-6 OPEN TANK MOUNT (80 GALLONS) WITH
DRYER
TABLE OF CONTENTS
34 3.10 IDENTIFICATION, ES-6 ENCLOSED TANK MOUNT (80 GALLONS)
WITH DRYER
36 3.11 IDENTIFICATION, ES-6 OPEN TANK MOUNT (120 GALLON)
38 3.12 IDENTIFICATION, ES-6 ENCLOSED TANK MOUNT (120 GALLON)
40 3.13 IDENTIFICATION, ES-6 OPEN TANK MOUNT (120 GALLON) WITH
DRYER
42 3.14 IDENTIFICATION, ES-6 ENCLOSED TANK MOUNT (120 GALLON)
WITH DRYER
44 3.15 PIPING AND INSTRUMENTATION DIAGRAM—STANDARD AND WYE-
DELTA
46 3.16 WIRING DIAGRAM—DUAL CONTROL FULL VOLTAGE 2-WIRE
48 3.17 WIRING DIAGRAM—DUAL CONTROL FULL VOLTAGE 3-WIRE
50 3.18 WIRING DIAGRAM—DUAL CONTROL 200-230/1/60 5 HP
52 3.19 WIRING DIAGRAM—DUAL CONTROL WYE-DELTA
54 3.20 WIRING DIAGRAM—SRS 25-100 115-230V/1/60
56 3.21 WIRING DIAGRAM—SRS 9-18 220-240V/1/50
58 3.22 WIRING DIAGRAM—SRS 24-30 220-240V/1/50
SECTION 4—INSTALLATION
61 4.1 LOCATION OF COMPRESSOR
61 4.2 VENTILATION AND COOLING
61 4.3 SERVICE AIR PIPING
61 4.4 FLUID LEVEL CHECK AND CHANGE PROCEDURE
62 4.5 MOTOR ROTATION DIRECTION CHECK
62 4.6 ELECTRICAL PREPARATION
SECTION 5—OPERATION
65 5.1 GENERAL
65 5.2 PURPOSE OF CONTROLS
66 5.3 INITIAL START-UP PROCEDURE
66 5.4 SUBSEQUENT START-UP PROCEDURE
66 5.5 SHUTDOWN PROCEDURE
SECTION 6—MAINTENANCE
67 6.1 GENERAL
67 6.2 DAILY OPERATION
67 6.3 MOTOR BEARING LUBRICANT
68 6.4 FLUID FILTER MAINTENANCE
68 6.5 COOLER MAINTENANCE
69 6.6 PARTS REPLACEMENT AND ADJUSTMENT PROCEDURES
75 6.7 TROUBLESHOOTING
75 6.8 TROUBLESHOOTING GUIDE
77 6.9 MAINTENANCE RECORD
TABLE OF CONTENTS
SECTION 7—PARTS LIST
79 7.1 PROCEDURE FOR ORDERING PARTS
80 7.2 RECOMMENDED SERVICE PARTS LIST
TABLE OF CONTENTS
Section 1
7
SAFETY
1.1 GENERAL
Sullair Corporation and its subsidiaries design and
manufacture all of their products so they can be
operated safely. However, the responsibility for safe
operation rests with those who use and maintain
these products. The following safety precautions are
offered as a guide which, if conscientiously followed,
will minimize the possibility of accidents throughout
the useful life of this equipment.
The compressor should be operated only by those
who have been trained and delegated to do so, and
who have read and understood this Operator's
Manual. Failure to follow the instructions, procedures
and safety precautions in this manual may result in
accidents and injuries. NEVER start the compressor
unless it is safe to do so. DO NOT attempt to operate
the compressor with a known unsafe condition. Tag
the compressor and render it inoperative by
disconnecting and locking out all power at source or
otherwise disabling its prime mover so others who
may not know of the unsafe condition cannot attempt
to operate it until the condition is corrected.
Install, use and operate the compressor only in full
compliance with all pertinent OSHA regulations and/
or any applicable Federal, State, and Local codes,
standards and regulations. DO NOT modify the
compressor and/or controls in any way except with
written factory approval.
While not specifically applicable to all types of
compressors with all types of prime movers, most of
the precautionary statements contained herein are
applicable to most compressors and the concepts
behind these statements are generally applicable to
all compressors.
1.2 PERSONAL PROTECTIVE
EQUIPMENT
A. Prior to installing or operating the compressor,
owners, employers and users should become
familiar with, and comply with, all applicable
OSHA regulations and/or any applicable Federal,
State and Local codes, standards, and regula-
tions relative to personal protective equipment,
such as eye and face protective equipment,
respiratory protective equipment, equipment
intended to protect the extremities, protective
clothing, protective shields and barriers and elec-
trical protective equipment, as well as noise
exposure administrative and/or engineering con-
trols and/or personal hearing protective equip-
ment.
1.3 PRESSURE RELEASE
A. Install an appropriate flow-limiting valve between
the service air outlet and the shut-off (throttle)
valve, either at the compressor or at any other
point along the air line, when an air hose exceed-
ing 1/2" (13mm) inside diameter is to be con-
nected to the shut-off (throttle) valve, to reduce
pressure in case of hose failure, per OSHA Stan-
dard 29 CFR 1926.302(b)(7) and/or any applica-
ble Federal, State and Local codes, standards
and regulations.
B. When the hose is to be used to supply a mani-
fold, install an additional appropriate flow-limiting
valve between the manifold and each air hose
exceeding 1/2" (13mm) inside diameter that is to
be connected to the manifold to reduce pressure
in case of hose failure.
C. Provide an appropriate flow-limiting valve at the
beginning of each additional 75 feet (23m) of
hose in runs of air hose exceeding 1/2" (13mm)
NOTE
OPERATOR IS REQUIRED TO READ
ENTIRE INSTRUCTION MANUAL.
SECTION 1
8
inside diameter to reduce pressure in case of
hose failure.
D. Flow-limiting valves are listed by pipe size and
flow-rated. Select appropriate valves accordingly,
in accordance with their manufacturer's recom-
mendations.
E. DO NOT use air tools that are rated below the
maximum rating of the compressor. Select air
tools, air hoses, pipes, valves, filters and other
fittings accordingly. DO NOT exceed manufac-
turer's rated safe operating pressures for these
items.
F. Secure all hose connections by wire, chain or
other suitable retaining device to prevent tools or
hose ends from being accidentally disconnected
and expelled.
G. Open fluid filler cap only when compressor is not
running and is not pressurized. Shut down the
compressor and bleed the receiver tank to zero
internal pressure before removing the cap.
H. Vent all internal pressure prior to opening any
line, fitting, hose, valve, drain plug, connection or
other component, such as filters and line oilers,
and before attempting to refill optional air line
anti-icer systems with antifreeze compound.
I. Keep personnel out of line with and away from
the discharge opening of hoses or tools or other
points of compressed air discharge.
J. DO NOT use air at pressures higher than 2.1 bar
for cleaning purposes, and then only with effec-
tive chip guarding and personal protective equip-
ment per OSHA Standard 29 CFR 1910.242 (b)
and/or any applicable Federal, State, and Local
codes, standards and regulations.
K. DO NOT engage in horseplay with air hoses as
death or serious injury may result.
1.4 FIRE AND EXPLOSION
A. Clean up spills of lubricant or other combustible
substances immediately, if such spills occur.
B. Shut off the compressor and allow it to cool.
Then keep sparks, flames and other sources of
ignition away and DO NOT permit smoking in the
vicinity when checking or adding lubricant or
when refilling air line anti-icer systems with anti-
freeze compound.
C. DO NOT permit fluids, including air line anti-icer
system antifreeze compound or fluid film, to
accumulate on, under or around acoustical mate-
rial, or on any external surfaces of the air com-
pressor. Wipe down using an aqueous industrial
cleaner or steam clean as required. If necessary,
remove acoustical material, clean all surfaces
and then replace acoustical material. Any acous-
tical material with a protective covering that has
been torn or punctured should be replaced
immediately to prevent accumulation of liquids or
fluid film within the material. DO NOT use flam-
mable solvents for cleaning purposes.
D. Disconnect and lock out all power at source prior
to attempting any repairs or cleaning of the com-
pressor or of the inside of the enclosure, if any.
E. Keep electrical wiring, including all terminals and
pressure connectors in good condition. Replace
any wiring that has cracked, cut, abraded or oth-
erwise degraded insulation, or terminals that are
worn, discolored or corroded. Keep all terminals
and pressure connectors clean and tight.
F. Keep grounded and/or conductive objects such
as tools away from exposed live electrical parts
such as terminals to avoid arcing which might
serve as a source of ignition.
G. Remove any acoustical material or other material
that may be damaged by heat or that may sup-
port combustion and is in close proximity, prior to
attempting weld repairs.
H. Keep suitable fully charged Class BC or ABC fire
extinguisher or extinguishers nearby when ser-
vicing and operating the compressor.
I. Keep oily rags, trash, leaves, litter or other com-
bustibles out of and away from the compressor.
J. DO NOT operate the compressor without proper
flow of cooling air or water or with inadequate
flow of lubricant or with degraded lubricant.
K. DO NOT attempt to operate the compressor in
any classification of hazardous environment
unless the compressor has been specially
designed and manufactured for that duty.
1.5 MOVING PARTS
A. Keep hands, arms and other parts of the body
and clothing away from couplings, belts, pulleys,
fans and other moving parts.
B. DO NOT attempt to operate the compressor with
the fan, coupling or other guards removed.
SECTION 1
9
C. Wear snug-fitting clothing and confine long hair
when working around this compressor, especially
when exposed to hot or moving parts.
D. Keep access doors, if any, closed except when
making repairs or adjustments.
E. Make sure all personnel are out of and/or clear of
the compressor prior to attempting to start or
operate it.
F. Disconnect and lock out all power at source and
verify at the compressor that all circuits are de-
energized to minimize the possibility of acciden-
tal start-up, or operation, prior to attempting
repairs or adjustments. This is especially impor-
tant when compressors are remotely controlled.
G. Keep hands, feet, floors, controls and walking
surfaces clean and free of fluid, water or other
liquids to minimize the possibility of slips and
falls.
1.6 HOT SURFACES, SHARP
EDGES AND SHARP
CORNERS
A. Avoid bodily contact with hot fluid, hot coolant,
hot surfaces and sharp edges and corners.
B. Keep all parts of the body away from all points of
air discharge.
C. Wear personal protective equipment including
gloves and head covering when working in, on or
around the compressor.
D. Keep a first aid kit handy. Seek medical assis-
tance promptly in case of injury. DO NOT ignore
small cuts and burns as they may lead to infec-
tion
1.7 TOXIC AND IRRITATING
SUBSTANCES
A. DO NOT use air from this compressor for respi-
ration (breathing) except in full compliance with
OSHA Standards 29 CFR 1910 and/or any appli-
cable Federal, State or Local codes or regula-
tions.
B. DO NOT use air line anti-icer systems in air lines
supplying respirators or other breathing air utili-
zation equipment and DO NOT discharge air
from these systems into unventilated or other
confined areas.
C. Operate the compressor only in open or ade-
quately ventilated areas.
D. Locate the compressor or provide a remote inlet
so that it is not likely to ingest exhaust fumes or
other toxic, noxious or corrosive fumes or sub-
stances.
E. Coolants and lubricants used in this compressor
are typical of the industry. Care should be taken
to avoid accidental ingestion and/or skin contact.
In the event of ingestion, seek medical treatment
promptly. Wash with soap and water in the event
of skin contact. Consult Material Safety Data
Sheet for information pertaining to fluid of fill.
F. Wear goggles or a full face shield when adding
antifreeze compound to air line anti-icer systems.
G. If air line anti-icer system antifreeze compound
enters the eyes or if fumes irritate the eyes, they
should be washed with large quantities of clean
water for fifteen minutes. A physician, preferably
an eye specialist, should be contacted immedi-
ately.
H. DO NOT store air line anti-icer system antifreeze
compound in confined areas.
I. The antifreeze compound used in air line anti-
freeze systems contains methanol and is toxic,
harmful or fatal if swallowed. Avoid contact with
the skin or eyes and avoid breathing the fumes. If
DANGER
Death or serious injury can result from
inhaling compressed air without using
proper safety equipment. See OSHA stan-
dards and/or any applicable Federal, State,
and Local codes, standards and regulations
on safety equipment.
SECTION 1
10
swallowed, induce vomiting by administering a
tablespoon of salt, in each glass of clean, warm
water until vomit is clear, then administer two
teaspoons of baking soda in a glass of clean
water. Have patient lay down and cover eyes to
exclude light. Call a physician immediately.
1.8 ELECTRICAL SHOCK
A. This compressor should be installed and main-
tained in full compliance with all applicable Fed-
eral, State and Local codes, standards and
regulations, including those of the National Elec-
trical Code, and also including those relative to
equipment grounding conductors, and only by
personnel that are trained, qualified and dele-
gated to do so.
B. Keep all parts of the body and any hand-held
tools or other conductive objects away from
exposed live parts of electrical system. Maintain
dry footing, stand on insulating surfaces and DO
NOT contact any other portion of the compressor
when making adjustments or repairs to exposed
live parts of the electrical system. Make all such
adjustments or repairs with one hand only, so as
to minimize the possibility of creating a current
path through the heart.
C. Attempt repairs in clean, dry and well lighted and
ventilated areas only.
D. DO NOT leave the compressor unattended with
open electrical enclosures. If necessary to do so,
then disconnect, lock out and tag all power at
source so others will not inadvertently restore
power.
E. Disconnect, lock out, and tag all power at source
prior to attempting repairs or adjustments to
rotating machinery and prior to handling any
ungrounded conductors.
1.9 LIFTING
A. If the compressor is provided with a lifting bail,
then lift by the bail provided. If no bail is provided,
then lift by sling. Compressors to be air-lifted by
helicopter must not be supported by the lifting
bail but by slings instead. In any event, lift and/or
handle only in full compliance with OSHA stan-
dards 29 CFR 1910 subpart N and/or any appli-
cable Federal, State, and Local codes, standards
and regulations.
B. Inspect points of attachment for cracked welds
and for cracked, bent, corroded or otherwise
degraded members and for loose bolts or nuts
prior to lifting.
C. Make sure entire lifting, rigging and supporting
structure has been inspected, is in good condi-
tion and has a rated capacity of at least the
weight of the compressor. If you are unsure of
the weight, then weigh compressor before lifting.
D. Make sure lifting hook has a functional safety
latch or equivalent, and is fully engaged and
latched on the bail or slings.
E. Use guide ropes or equivalent to prevent twisting
or swinging of the compressor once it has been
lifted clear of the ground.
F. DO NOT attempt to lift in high winds.
G. Keep all personnel out from under and away
from the compressor whenever it is suspended.
H. Lift compressor no higher than necessary.
DANGER
All field equipment must be tested for elec-
trostatic fields prior to servicing or making
contact with the machine using the follow-
ing or equivalent test equipment:
• 90-600 VAC: Volt detector such as
Fluke Model 1AC-A
• 600-7000 VAC: Voltage detector
such as Fluke Networks Model
C9970
It is the responsibility of each organization
to provide/arrange training for all their
associates expected to test for electrostatic
fields.
SECTION 1
11
I. Keep lift operator in constant attendance when-
ever compressor is suspended.
J. Set compressor down only on a level surface
capable of safely supporting at least its weight
and its loading unit.
K. When moving the compressor by forklift truck,
utilize fork pockets if provided. Otherwise, utilize
pallet if provided. If neither fork pockets or pallet
are provided, then make sure compressor is
secure and well balanced on forks before
attempting to raise or transport it any significant
distance.
L. Make sure forklift truck forks are fully engaged
and tipped back prior to lifting or transporting the
compressor.
M. Forklift no higher than necessary to clear obsta-
cles at floor level and transport and corner at
minimum practical speeds.
N. Make sure pallet-mounted compressors are
firmly bolted or otherwise secured to the pallet
prior to attempting to forklift or transport them.
NEVER attempt to forklift a compressor that is
not secured to its pallet, as uneven floors or sud-
den stops may cause the compressor to tumble
off, possibly causing serious injury or property
damage in the process.
1.10 ENTRAPMENT
A. If the compressor enclosure, if any, is large
enough to hold a man and if it is necessary to
enter it to perform service adjustments, inform
other personnel before doing so, or else secure
and tag the access door in the open position to
avoid the possibility of others closing and possi-
bly latching the door with personnel inside.
B. Make sure all personnel are out of compressor
before closing and latching enclosure doors.
NOTES
12
Section 2
13
ES-6 USER MANUAL
DESCRIPTION
2.1 INTRODUCTION
Your new Sullair flood-lubricated rotary screw air
compressor will provide you with improved reliability
and greatly reduced maintenance.
Compared to other types of compressors, the Sullair
rotary screw is unique in mechanical reliability, with
"no wear" and "no inspection" required of the working
parts within the compressor unit.
Read Section 6: Maintenance to keep your
compressor in top operating condition. Should any
questions arise which cannot be answered in the
following text, call your nearest Sullair office or the
Sullair Corporation Service Department.
2.2 DESCRIPTION OF
COMPONENTS
Refer to Figure 2-1. The components and
assemblies of the ES-6 Series air compressor are
clearly shown. The complete compressor consists of
an encapsulated compressor system, inlet system,
cooling system and control system.
The compact design of the ES-6 Series air
compressor provides easy access to all serviceable
components.
2.3 ENCAPSULATED
COMPRESSOR SYSTEM,
FUNCTIONAL DESCRIPTION
Refer to Figure 2-2. The encapsulated compressor
includes compressor unit, fluid management system,
and motor section. The Sullair compressor unit is a
single-stage positive displacement lubricated type
compressor. This unit is equipped with tapered roller
bearings on the discharge, and cylindrical roller
bearings on the inlet end for high load carrying
capacity. This unit provides continuous pulse-free air
compression to meet your needs. With a Sullair
compressor there will be no maintenance or internal
inspection of the compressor
.
Fluid is injected into the compressor unit in large
quantities and mixes directly with the air as the rotors
turn, compressing the air. The fluid flow has three
main functions:
1. As coolant, it controls the rise of air tempera-
ture normally associated with the heat of
compression.
2. It seals the leakage paths between the rotors
and the stator and also between the rotors
themselves.
3. It acts as a lubricating film between the
rotors allowing one rotor to directly drive the
other, which is an idler.
The air/fluid mixture discharges directly into the fluid
management system.
The fluid cooler bypass valve helps assure proper
cooling by directing the fluid to the fluid cooler when
discharge temperature reaches the thermostat
temperature setting.
During start-up in cool ambient conditions, the cooler
pressure drop will cause the filter bypass valve to
open up, assuring adequate fluid supply to the
compressor.
All fluid entering the compressor unit passes through
WARNING
DO NOT remove caps, plugs and/or other
components when compressor is running
or pressurized. Stop compressor and
relieve all internal pressure before doing so.
ES-6 USER MANUAL SECTION 2
14
the replaceable fluid filter element. This replaceable
filter element contains a built-in bypass valve. Under
conditions of restricted flow through the element, the
bypass valve helps ensure adequate compressor
fluid flow, as well as helps prevent element failure.
F
LUID MANAGEMENT SYSTEM
The fluid management system consists of a
multichambered primary/secondary separator, the
final air/fluid separator element, cooler bypass group
and fluid filter.
As compressed air/fluid enters the sump, the first
fluid separation takes place due to a reduction of flow
speed coupled with a change of direction of the flow
within the sump housing. Then the compressed air
reaches the separator, where the finest fluid drops
and mist are separated.
M
OTOR/DRIVE SECTION
The motor/drive section consists of a squirrel cage
induction motor and integrated drive gearing which is
separated from the motor by a replaceable shaft
seal.
The minimum pressure/discharge check valve is
mounted on the compressor drive housing. Its
functions are as follows:
1. Maintain a minimum sump pressure of 60
psig (4.1 bar) under full load operation to
help assure adequate fluid pressure.
2. Act as a check valve to isolate the compres-
sor from the system at shutdown or unload.
SECTION 2 ES-6 USER MANUAL
15
Figure 2-1: Description of Components
1. Air Inlet System
2. Pressure Regulator
3. Pressure Gauge
4. Discharge Temp Gauge
5. Unload Solenoid Valve
6. Air/Fluid Seperator Element Access
Cover
7. Fluid Fill Plug
8. Fluid Filter Element
9. Fluid Level Sight Glass
10. Encapsulated Compressor System
11. Pressure Relief Valve
12. Cooling System
13. Drain Valve
14. Air Pressure Switch
15. Hourmeter
16. Motor Start Selector Switch
17. Motor Overload Reset Switch
ES-6 USER MANUAL SECTION 2
16
2.4 COMPRESSOR COOLING
SYSTEM FUNCTIONAL
DESCRIPTION
The compressor cooling system consists of a fluid
cooler, fan and cooler shroud.
The fan is mounted on the motor's shaft end opposite
the compressor. Air is drawn over the motor as well
as through the cooler. The air provides motor cooling
and removes compression heat from the fluid.
2.5 AIR INLET SYSTEM,
FUNCTIONAL DESCRIPTION
The compressor inlet system consists of a dry-type
air filter and an air control valve. Reacting on a
pressure signal, the valve closes the intake for
unloaded operation. The valve also acts as a check
valve upon shutdown.
Figure 2-2: Encapsulated Compressor System
1. Aftercooler and Fluid Cooler
2. Compressor Unit
3. Fluid Fill Plug
4. Fluid Filter
5. Fluid Level Sight Glass
6. Air/Fluid Separator
7. Pressure Relief Valve
8. Discharge Air
9. Air
10. Air/Fluid
11. Fluid
SECTION 2 ES-6 USER MANUAL
17
2.6 CONTROL SYSTEM,
FUNCTIONAL DESCRIPTION
The purpose of the compressor control system is to
maintain compressor capacity to meet the system
demand.
It consists of an inlet valve, pressure regulator valve,
solenoid valve, control lines and the motor start
selector switch.
The selector switch has three settings: MANUAL/
START, OFF/RESET and AUTOMATIC START/
STOP.
M
ANUAL MODE
In the manual mode the ball valve should be closed
to isolate the pressure regulator. The compressor
motor will start and the air control solenoid will be
energized (closed.) During this time the inlet valve is
fully open due to inlet air flow, and the compressor
will start to deliver compressed air. When the air
demand is less than the rated flow for the
compressor, the service line pressure will rise to the
pressure switch cut-out setting. The system pressure
switch opens, interrupting the electrical power to the
solenoid valve. The solenoid valve opens allowing
pressure to be applied to the inlet valve causing the
inlet valve to fully close. The compressor will
continue to run (unloaded) until the line pressure
drops to the low setting of the pressure switch--the
pressure switch closes, reenergizing the normally
open solenoid valve and allows the compressor to
load again.
M
ANUAL MODULATION CONTROL MODE
In the modulation control mode the ball valve should
be open to allow pressure to the pressure regulator.
The compressor motor will start and the system
pressure will rise until it reaches the set point of the
pressure regulator. The pressure regulator will them
begin to open allowing pressure to be applied to the
inlet valve. The pressure regulator will modulate the
inlet valve to match system demand.
O
FF/RESET MODE
The compressor motor, if running, will stop if the off/
reset position is selected. If the compressor during
normal running has a fault caused by either overload
or high discharge temperature, the compressor will
stop. After a fault has been cleared, the compressor
can not be restarted unless the Off/Reset mode is
selected on the selector switch, prior starting in any
other mode of operation.
A
UTOMATIC MODE
In the automatic mode of operation, the compressor
operates the same as in the manual mode except
that when the pressure switch unloads the machine
the compressor motor will stop. The motor will
automatically restart when the line pressure drops to
below the set-point of the air pressure switch. If the
compressor is equipped with a wye-delta starter, the
compressor will not restart until the compressor
sump pressure drops to the minimum set-point on
the sump pressure switch. It is not recommended to
open the pressure regulator ball valve for the
automatic mode of operation.
2.7 INSTRUMENTATION,
FUNCTIONAL DESCRIPTION
Due to the simplicity of the ES-6 Series compressor,
the only instrumentation necessary is a line pressure
gauge which is located on the left side of the
electrical control center and a discharge temperature
gauge which is located on the right side of the
electrical control center. The line pressure gauge
reads plant air system pressure only.
NOTE
At compressor shutdown, the sump pres-
sure is released to atmosphere through
the solenoid valve. The line pressure
gauge will continue to read system pres-
sure.
18
NOTES
Section 3
19
ES-6 USER MANUAL
SPECIFICATIONS
3.1 TABLE OF SPECIFICATIONS
Table 3-1: 60 Hz Model
MODEL HP/KW
Cap.
ACFM
M
3
/Min
Max.
Pressure
PSIG/BAR
dBA (I) with
canopy /
without
canopy
DIMENSIONS
Length (II) Width (III) Height (IV) Weight (V)
in mm in mm in mm lb. kg
ES-6 5H 5/4 18/.51 125/8.6 68/80 29.5 749 21.4 544 22.11 562 230 104
ES-6 5XH 5/4 13/.37 175/12 68/80 29.5 749 21.4 544 22.11 562 230 104
ES-6 7.5H 7.5/5.5 28/.79 125/8.6 69/82 31.5 800 21.4 544 22.11 562 270 122
ES-6 7.5XH 7.5/5.5 20/.57 175/12 69/82 31.5 800 21.4 544 22.11 562 270 122
ES-6 10H 10/7.5 38/1.08 125/8.6 70/85 31.5 800 21.4 544 22.11 562 280 127
ES-6 10XH 10/7.5 30/.85 175/12 70/85 31.5 800 21.4 544 22.11 562 280 127
(I) Ratings of dBA at one meter
(II) Enclosure option length is 44 in./711 mm.
(III) Enclosure option width is 28 in./711 mm.
(IV) Enclosure option height is 28 in./711 mm
(V) For enclosure models, add 170 lbs./77 kg to base weight of machine
Table 3-2: 50 Hz Model
MODEL HP/KW
Cap.
ACFM/
M
3
/Min
Max.
Pressure
PSIG/BAR
dBA (I) with
canopy /
without
canopy
DIMENSIONS
Length (II) Width (III) Height (IV) Weight (V)
in mm in mm in mm lb. kg
ES-6 5L 5/4 21.2/.60 110/7.5 68/80 29.5 749 21.4 544 22.11 562 230 104
ES-6 5HH 5/4 17.3/.49 150/10 68/80 29.5 749 21.4 544 22.11 562 230 104
ES-6 5XH 5/4 13.4/.38 175/12 68/80 29.5 749 21.4 544 22.11 562 230 104
ES-6 7.5L 7.5/5.5 30/.85 110/7.5 69/82 31.5 800 21.4 544 22.11 562 270 122
ES-6 7.5HH 7.5/5.5 24.4/.69 150/10 69/72 31.5 800 21.4 544 22.11 562 270 122
ES-6 7.5XH 7.5/5.5 20.5/.58 175/12 69/82 31.5 800 21.4 544 22.11 562 270 122
ES-6 10L 10/7.5 39.2/1.11 110/7.5 70/85 31.5 800 21.4 544 22.11 562 280 127
ES-6 10HH 10/7.5 33.9/.96 150/10 70/85 31.5 800 21.4 544 22.11 562 280 127
ES-6 10XH 10/7.5 28.2 175/12 70/85 31.5 800 21.4 544 22.11 562 280 127
(I) Ratings of dBA at one meter
(II) Enclosure option length is 44 in./711 mm.
(III) Enclosure option width is 28 in./711 mm.
(IV) Enclosure option height is 28 in./711 mm
(V) For enclosure models, add 170 lbs./77 kg to base weight of machine
ES-6 USER MANUAL SECTION 3
20
3.2 COMPRESSOR
LUBRICATION GUIDE
Consult Figure 3-1 for fluid fill port location. For best
value and longest uninterrupted service, the ES-6
compressor is factory filled with Sullube, a long life
lubricant, unless a different lubricant is requested.
If, due to availability or other reasons, other fluids are
required, follow Section 3.3, Section 3.4 and Table 3-
7:Lubrication Guide.
Table 3-3: Compressor
Type: Single Stage Fluid Injected Screw Compressor
Minimum Full Load Operating Pressure: 60 psi (4.1 bar)
Maximum Full Load Operating Pressure: Nameplate Pressure (VI)
Bearing Type: Anti-friction
Cooling: Pressurized Fluid
Lubricant: See Section 3.2: COMPRESSOR LUBRICATION
GUIDE
Sump Capacity: 4.6 quarts (4.35 liters)
(VI) Compressors are available for pressures up to 175 psi (12.1 bar).
Table 3-4: Motor
60Hz 50Hz
Type: 5, 7.5, 10HP/4, 5.5 & 7.5 KW 1.15 S.F. 5, 7.5, 10HP/4, 5.5 & 7.5 KW
Synchronous Speed 1800 RPM 1500 RPM (5, 7.5HP/4, 5.5 KW)
3000 RPM (10HP/7.5KW)
Voltage:
Standard All Sizes Optional All Sizes 230/460v 3 Phase 200v 3 Phase 380/4155 3 Phase 380/415 3 Phase
Optional All Sizes 575v 3 Phase 200v 3 Phase 380/415 3 Phase
Optional 5hp Only 230v Single Phase -
Type: Totally Enclosed Air Over Totally Enclosed Air Over
Insulation Class: “F” “F”
Maximum Ambient Temp.: 40°C (104°F) 40°C (104°F)
Shaft Diameter Fan: Nominal 5/8’’ Nominal 5.8”
Key Size Fan: Nominal 3/16” X 1 1/4” Nominal 3/16” X 3/16” X 1 1/4”
Table 3-5: Fluid Filter (internal bypass valve set at 25 psig)
Type: Spin on, Sullair Proprietary
Micron: 23 Microns Abs.
Table 3-6: Fluid Separator Element
Type: Push In Cartridge, Sullair Proprietary
Efficency at Maximum Capacity: 3PPM Maximum
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84