Cumberland POWERTRAK Owner's manual

Type
Owner's manual
4801-0153 PowerTrak 3 Wire Conversion PowerTrak
PowerTrak Wiring Harness
9 Conductor PowerTrak Connection to 3 Wire Controller
If you have a standard PowerTrak with a PCB-135A circuit board:
1. Disconnect the nine conductor wire, and limit switch and motor harness from the board.
2. Plug harness provided into motor, and limit switch harness.
3. Use Yellow(COM), Red(CLOSE), Brown(OPEN) control wires to go to Farm Hand Controls.
4. Use Green(GROUND), Black(HOT), White(Neutral) to supply 120V/240V power (depending on
model) to the PowerTrak.
5. Attach Label (Included) to inside of PowerTrak Door for future reference.
J3
12
11
10
9
8
7
6
5
1
2
3
4
J2
1
2
3
4
J1
9
8
7
6
5
4
3
2
1
J2
9
8
7
6
5
4
3
2
1
FAN-UPPER1
FAN-LOWER2
FAN-LOWER1
4 Pin from motor
12 Pin from limit switches
Blue
White
Black
Red
FAN-UPPER2
Plug harness into 12 pin limit
switch connector.
110vac White
Com Yellow
110vac Black
Close Red
Open Brown
Ground
Power to Unit 110VAC
Control Wires to Controller
9 Pin from controller