Carrier HUMCCSBP2017-A Series Owner's manual

Category
Dehumidifiers
Type
Owner's manual

This manual is also suitable for

HEATING & COOLING
HOMEOWNER'S MANUAL
Model HUMCCLFP1025-A--
Fan-Powered Humidifier
Model HUMCCSFP1016-A--
Fan-Powered Humidifier
Model HUMCCLBP2018-A--
Bypass Humidifier
Model HUMCCWTR2019-A--
Water-Saver Bypass Humidifier
Model HUMCCSBP2017-A--
Bypass Humidifier
REFRESHING MOISTURE...
AS NATURE INTENDED
Congratulations on your excellent choice and sound investlnent
in this addition m your holne COlnfortsystem.
Your hulnidifier represents both the latest in engineering devel-
oplnent and the cuhnination of lnany years of experience t}Oln
one of the lnost reputable lnanufacturers of comfort systems.
Your new unit is alnong the most energy-efcient and reliable
holne hulnidifiers available today. To assure its dependability,
spend a few lninutes now with this booklet. Learn about the op-
eration of your hulnidifier and the small alnount oflnaintenance
it takes to keep it operating at peak efficiency.
With lninilnal care, your hulnidifier will provide you and your
_amily with lnoist, spring-fresh air froln season to season and
year to year.
YOUR HOME HUMIDIFIER
YOUR HOME CAN BE DRIERTHAN DEATH VALLEY
During the heating season, your holne can becolne uncolnfort-
ably dry. This is because cold winter air holds very little lnois-
rare. When outdoor air is warmed to average rooln telnperamre,
its relative hulnidity £hlls to even lower levels. Refer to Table 1
for a comparison of the levels of relative humidity for a few sam-
ple enviromnents.
Table 1 -- Relative Humidity Comparison
HEATED HOME
RECOMMENDED
RELATIVE
HUMIDITY
35%
SAHARA
DESERT
25%
DEATH
VALLEY
23%
HEATED HOME
AVERAGE
5-15%
Parched air can cause the wood used in the construction of your
house and furnishings to dry, crack, aM split. Draperies and up-
holstery may age prelnaturely. Amaoying static electric shock
and cling are lnore prevalent. Your tlaoat, nasal passages, si-
nuses, and skin are more susceptible to irritating dryness. You
may even have to set the therlnostat higher than otherwise nec-
essary just to feel warm.
MOISTURE MAKES A REFRESHING DIFFERENCE
Proper hulnidity comrol can alleviate problelns caused by exces-
sive dryness. Furnishings and fabrics take on a more lustrous
appearance. Houseplants tl_ive. Static electricity is significantly
reduced in a properly hulnidified home. Your £hmily will breathe
lnore easily and ilnd relief from the cool, drafty feeling coin-
lnonly experienced in overly dry holnes. The additional lnoisture
supplied by your humidifier may enable you to reduce the tem-
perature setting on your therlnostat without any loss of indoor
COlnfort.
HOWYOUR HUMIDIFIERWORKS
Your hulnidifier adds water lnolecules to the air inside your
holne. Although the rate of humidification is variable, it may
exceed one-half gallon of water per hour. That's a healthy drink
for a dry household. The typical process of lmlnidification be-
gins when water flows through the humidifier vah,e and soaks
the large evaporator pad. Hot, dry air [}oln the furnace passes
through the pad and absorbs the water. Then, this lnoisture-laden
air is distributed throughout the house via the ductwork. See Fig.
1, 2, and 3.
Fig. 1 Fig. 2
TYPICAL
INSTALLATIONS
Fig. 3
OPERATING YOUR HUMIDIFIER
Your new hulnidifier is designed to operate as part of your home
heating system. It will perforln at lnaximuln efciency if these
recolranendations are followed:
The hulnidifier is comrolled by a hulnidistat. Adjust the
hulnidistat setting according to the outside telnperature. Refer
to Table 2 as a general guide. If after several days, the air in
your home seems too moist, lower the humidistat setting. Con-
densation on single-pane windows indicates excessive mois-
ture. If the air is too dry, increase the setting. Dry throat and
nasal passages indicate dry air.
All models come with a humidistat. Continuous blower oper-
ation provides for constant hulnidification. It may also contrib-
ute to greater personal COlnfort because continuous blower
operation minimizes telnperature differences throughout the
home. Furtherlnore, a system equipped with an electronic air
cleaner offers the added benefit of full-tilne air filtration.
Table 2--HumidistatSettings
OUTSIDE RECOMMENDED
TEMPERATURE HUMIDISTAT SETTING
(°F) (% RELATIVE HUMIDITY)
-20 15
-10 20 (LOW)
-0 25
10 30
20 35
30 40 (NED)
Supply- and return-air grilles should not be blocked by items
such as drapes, flmfiture, and toys. Restricted airflow reduces
the efficiency of the humidifier, as well as that of the whole com-
fort system.
The humidifier unit lnUStbe properly lnaintained on a regular
basis.
STARTUP PROCEDURES
1. Open the saddle valve on the water supply line. (See Fig. 4.)
Set humidistat to the desired relative humidity. (See Fig. 5
and Table 2.)
2. Turn the fimmce on and adjust the therlnostat to a high tem-
perature setting. Be sure that the fitmace blower is operating.
3. Check to see if water is flowing into the humidifier.
Fig. 7 -- Model HUMCCLP1025-A--
Fig. 4 -- Saddle Valve Fig. 5
On a Model HUMCCLBP or Model HUMCCLFP humidifi-
er, loosen the thulnbscrew that holds the distributor cover to the
mp of the cabinet. Lift up the distributor cover slightly to lnake
certain that water is flowing from the solenoid valve into the
distributor pan. Do not lift the cover offthe cabinet more than
1 in. when water is flowing. (See Fig. 6 or 7 according to the
lnodel you own.)
DISTRIBUTOR PAN J
CABINET_ NLET _ _SOLENO_DVALVE D_STR_BUTORPAN
DRAIN J
Fig. 8 -- Model HUMCCSBP2017-A--
BOTTOM ACCESS -Z
PANEL
Fig. 6 -- Model HUMCCLBP2018-A--
On a Model HUMCCSBP humidifier, gemly pull the latch
that secures the access door. Relnove the door. Check to see if
water is flowing froln the solenoid valve into the evaporator pad.
(See Fig. 8.)
On a Model HUMCCSFP hulnidifier, open the side door or
the front cover. If the front cover is opened, hold the pad assem-
bly in place. Check to see if water is flowing from the solenoid
valve imo the distributor pan. (See Fig. 9.)
On a Model HUMCCWTR unit, look through the window on
front of the unit to see that the evaporator pad is rotating and
water is flowing. (See Fig. 10.)
The Model HUMCCWTR is controlled by a float valve. Turning
off the fimmce will not affect the water flow until float level is
achieved. (See Fig. 11.)
Fig. 9 -- Model HUMCCSFP1016-A--
4. Turn off the furnace. When the blower stops, look into the
humidifier to make sure the water is not flowing into the
unit.
5. Replace the cover assembly and *hsten securely.
6. Now, mrn the furnace on and set the thermostat for desired
rooln telnperature.
SHUTDOWN PROCEDURES
To shut down your humidifier, close the saddle vane on the wa-
ter line. Then turn off the humidistat. When set to the OFF posi-
tion, the humidistat shuts offthe electrical power m the solenoid
valve on the humidifier.
NOTE: If your holne comfort system includes cooling, be sure
the water supply to your humidifier is turn ed off during the cool-
ing season. Close the damper located in the bypass duct if one
is installed. If your humidifier is a Model HUMCCWTR, drain
and clean the water pan as described in cleaning procedures.
PERFORMING ROUTINE MAINTENANCE
With the proper lnaintenance and care, your humidifier will op-
erate econolnically and dependably. Maintenance can be accom-
plished easily by referring to the following directions. However,
before perforlning any lnaintenance, consider these ilnportant
safety precautions:
DISCONNECT ALL ELECTRICAL POWER TO THE
HUMIDIFIER AND FURNACE BEFORE PERFORMING
ANY SERVICE OR MAINTENANCE TO AVOID PER-
SONAL INJURY.
- CABINET
PAN
Fig. 10 -- Model HUMCCWTR2019-A--
NOTE: THERE MAY BE MORE THAN 1 ELECTRICAL
DISCONNECT SWITCH.
ALTHOUGH SPECIAL CARE HAS BEEN TAKEN TO
MINIMIZE SHARP EDGES IN THE CONSTRUCTION OF
YOUR HUMIDIFIER, BE EXTREMELY CAREFUL WHEN
HANDLING PARTS OR REACHING INTO THE WNIT TO
AVOID PERSONAL INJURY.
Your hulnidifier has been designed for easy disassembly to sim-
plii_ cleaning and selwicing. Your unit lnUSt be kept clean m
lnaintain its efficiency.
Regular inspection allows you to deterlnine the cleaning sched-
ule best suited to your humidifier's operating conditions. The
frequency for required lnaintenance will depend most upon the
available water supply. In areas where hard water and high lnin-
eral content are prevalent, lnore frequent cleaning and servicing
may be required.
At minimum, the humidifier will need to be cleaned at the be-
ginning of every heating season.
CLEANING PROCEDURES
Models HUMCCLBP, HUMCCSBP, HUMCCLFP, and
HUMCCSFP
1. Turn off all electrical power to the humidifier and fimmce
or fan coil.
2. Turn offthe humidifier's water supply. (See Fig. 4.)
3. Disassemble the humidifier.
To disasselnble a Model HUMCCSBP humidifier, gently pull
the latch that secures the access panel. Relnove the door and
slide the evaporator pad assembly out of the unit. (See Fig. 8.)
To disassemble either a Model HUMCCLBP or Model
HUMCCLFP humidifier, first relnove the water supply con-
nection to the solenoid valve. Next, relnove the screw that
holds the distributor cover to the cabinet, and lift offthe cover.
Discom_ect the drain line from the sump and loosen the
thumbscrew(s) holding the sump to the cabinet. Relnove the
sump. Relnove evaporator pad assembly. (See Fig. 6 or 7,
according to the lnodel you own.)
To disassemble a Model HUMCCSFR the pad assembly can
be relnoved froln the side access door or the front cover. When
relnoving the side door, lift the pad asselnbly up by holding the
tabs and slide the asselnbly out. When relnoving the front cover
on Model HUMCCSFR discomaect the quick comaects m the
solenoid valve, unscrew the 4 screws to the front cover, snap
loose the mp and bottom catches, and lay the front cover aside.
Once the front cover is off; lift the pad assembly up aM twist it
out. The pad assembly consists of 4 parts; the distributor pan,
fralne, sump, and the evaporator pad. Pull the distributor pan
apart from the fralne and the evaporator pad can be relnoved. Do
not force the evaporator pad in or out without relnoving the dis-
tributor pan as this will distort the pad.
4. Clean the humidifier's external COlnponents.
If your humidifier is a Model HUMCCSBP humidifier, wash
the access door and outlet drain portion of the cabinet. Make
sure the drain is open.
If your humidifier is a Model HUMCCLBP or HUMCCLFR
wash the distributor cover, sump cover, and cabinet. Be sure the
inlet ports are open and clean. Then, clean the sump with a solu-
tion of detergent and water.
5. Clean the internal colnponents of your humidifier. Wash the
distributor pan with a mild detergent and warm water. Be
sure holes and slots in the pan are clean and unobsmlcted.
Wash the evaporator pad assembly in a detergent solution.
If there are scale deposits on the pad, soak it in ordinary
household vinegar. If the pad is covered by a heavy deposit
of scale, or if the local water supply has high sullhte or cal-
cium content, replace the pad with a new one. Contact your
dealer for replacement part.
6. Reassemble your humidifier.
7. Turn on the electrical power and water supplies. Refer to
the starmp procedures.
Model HUMCCWTR
1. Turn off all electrical power to the humidifier and furnace
or £hn coil.
2. Turn off the humidifier's water supply. (See Fig. 4.)
3. Drain water from the unit. Place a pail underneath the drain
plug located on the bottom of the humidifier cabinet. Lift
the tab on the drain plug and relnove the plug. Allow all
water m drain fiOln the unit. (See Fig. 12.)
4
4.RelnovethefrontdoorfrolnthehumidifienRotatethe
latchesone-halfturn,thenpullthedoorforward.
5.Relnoveandinspecttheevaporatorpadassembly.Liftthe
bearingfromitsretainer.(SeeFig.10.)Pulltheassembly
awayfromthelnotortodisengagetheassemblyshalifroln
themotorcoupling.Relnoveassemblytl_oughtheaccess
opening.
Inspecttheevaporatorpad.If thepadisheavilyloadedwith
scale,orifthelocalwaterhasahighsulfhtecontent,replacethe
pad.Contactyourdealerforreplacelnentpart.
NOTE:Forbestperforlnance,theevaporatorpadshouldbe
replacedbeforeeachheatingseason.
6.Inspectthefloatassembly.Relnovethefloatarmfromthe
valvebodybyslidingoutthepinandliftingoffthefloat
arm.(SeeFig.11.)Inspecttherubbervalveseatlocatedin-
sidethefloatarm.If theseatappearstobenickedorworn,
inverttheseatorreplaceitwiththesparevalveseatlocated
onthefloatarm.Inspectthewateropeninginthevalve
body.If theopeningisclogged,useapintorelnovethe
obstruction.Removeanyaccumulateddepositsfrolnthe
valvebodyandfloatarm.
7.Cleanthewaterpanandunitcabinet.Tiltthewaterpanand
liftit fiOlntheunit.Washthepanwithwarm,soapywater.
Flexthepantoloosenaccumulatedscale.Washtheunitin-
terior,relnovinganyaccumulateddeposits.Inspectthe
drainlinetoinsurethatnoblockagehasoccurred.Cleanas
required.(SeeFig.12.)
8.ReassembleyourModelHUMCCWTRhumidifier.Rein-
sertthewaterpananddrainplug.Ensurethattheoverflow
tubeisinsertedintotheholeatthebottomofthecabinet.
Attachthefloatarmtothevalvebodybyaligningtheholes
onbothpartsandreinsertingthepin.Do notfbrce or bend
thepin. The float arm should have flee up-and-down move-
lnent. Install the evaporator pad assembly. Ensure that the
square shaft engages the lnotor coupling and that the bear-
ing washer is located inside the bearing retainer. Turn the
water on. Adjust float by rotating until water covers inside
of foaln drum. Attach the access door and turn the latches.
FLOAT ARM PiN --_
W; LAT
Fig. 11 -- Float Arm Removal
f Ho_.,,o,F,ERHOOS,NG H
fWATERPAN H
Fig. 12 -- Cleaning Water Pan and Unit Cabinet
9. Turn on electrical power supplies. Refer to starmp proce-
dureslisted on page 3.
BEFOREYOU REQUEST A "SERVICE CALL"
BEFOREYOU CALL FOR SERVICE, CHECK FOR
THESE EASILY SOLVED PROBLEMS:
Check the lnain power discomaect
switch. Verify that the circuit break-
ers are on and that fuses have not
blown. If you lnUStreset breakers or
replace filses, do so only once. Con-
tact your selwicing dealer for assis-
tance if the breakers trip or the filses
blow a second time.
If the hulnidity level is too low, check the hulnidistat setting.
Confirln that the saddle valve is turned on. Check the evapora-
tor pad, and clean or replace the pad as necessary. Check water
level in Model HUMCCWTR.
Check for sufficient airflow. Check the fimmce filter or elec-
mmic air cleaner for excessive accumulations of dirt. Check for
blocked return- or supply-air grilles. Be sure grilles are open
and unobstructed.
If water drips froln the humidifier, check the drain hose for
kinks or obstructions. If your unit is a Model HUMCCWTR,
dripping may indicate that the float valve requires adjustlnent.
If your colnfort system still fhils to operate properly, contact
your selwicing dealer for troubleshooting and repairs. Specify
your apparent probleln, and state the lnodel and serial nulnbers
of your equiplnent. (You should have theln recorded where
noted in this booldet.) With this inforlnation, your dealer lnay be
able to offer helpfid suggestions over the phone, or save valuable
time through knowledgeable preparation for the selwice call.
REGULAR DEALER MAINTENANCE
In addition to the routine lnaintenance that you perforln, your
humidifier should be inspected regularly by a properly trained
selwice technician. The inspection (preferably each year, but at
least every other year) should include the following:
Routine inspection of the hulnidifier. Cleaning, if necessary.
Cleaning or replacelnent of the evaporator pad as required.
A check of all electrical wiring and comaections.
A check of water comaections to the unit.
Operational check of the complete colnfort system to deter-
mine acttml worldng condition. Necessary repair and/or adjust-
lnent should be perforlned at this time.
Your selwicing dealer lnay offer an econolnical service contract
that covers seasonal inspections. Ask for further details.
Record the lnodel and serial nulnbers of your new hulnidifier in
the following spaces. This inforlnation, along with the other
ready-reference facts requested below, may be required if you
should ever need inforlnation or selaqce.
Model No.
Serial No.
Date Installed
Dealer Name
Address
City
State
Telephone
Zip
Carrier
A United Technologies Company
TO OBTAIN INFORMATION ON PARTS: Consult your installing dealer or the classified section of your local telephone directory under the
"Heating Equipment" or "Air Conditioning Contractors & Systems" heading for dealer listing by brand name.
Have available the Model No., Series Letter, & Serial No. of your equipment to ensure correct replacement part
Carrier Corporation Indianapolis, IN 46231
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Copyright 1998 Carrier Corporation Form: OMHUM-1 Replaces: OM49-9 Printed in the US.A. 7-98 PC 101 Catatog No. 03HU-MC0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Carrier HUMCCSBP2017-A Series Owner's manual

Category
Dehumidifiers
Type
Owner's manual
This manual is also suitable for