ROUND TOP TERMINATION
INSTALLATION INSTRUCTIONS
RTTL-8DM AND RTTL-8HT
Note:
For nonchase installation see column 3.
1. Construct the chase as illustrated in
Figure 1.
Note:
The shortest vertical
side must be at least 30 inches high and
the minimum inside dimension must be
at least 17
1
/2".
2. Add the pipe sections to the chimney
system as outlined in the fireplace in-
stallation instructions until the last piece
of the chimney is a maximum of 17" be-
low the top of the chase (see Figure 1).
3. Fabricate a flashing having an 13
1
/4"
diameter hole centered over the chim-
ney end with a 2" collar around the hole
(see Figure 2). Attach noncombustible
spacers at each corner and place the
flashing over the chase.
Figure 1 - Constructing the Chase
Figure 2 - Constructing the Chase Top
Flashing
As Required
28 Gauge
Galvanized Steel
13
1
/4"
Diameter
4. Secure the flashing through the sides
with 8-penny nails or sheet rock screws.
5. Place the termination cap over the
opening and slip the 8" stainless steel
inner pipe into the stainless steel chim-
ney section and the galvanized sleeve
over the chimney outlet. Lower the ter-
mination cap until its tabs rest on the
flashing collar. Bend the tabs down and
secure them with sheet metal screws.
10' RULE
The chimney flue gas outlet of the termina-
tion must be a minimum distance of 3 feet
above the highest point where the pipe pen-
etrates the roof and must be a minimum
distance of 2 feet above the highest point of
the roof within a horizontal distance of 10
feet (see Figure 5).
Figure 3 - Installing Termination Cap
Termination Cap
1" Spacer
Note:
Do Not Seal the Ventilation Openings.
Chase
Chase Top
Flashing
1
1
/2" Space
Double Wall
Chimney
Flashing
Note:
Do Not Seal the Ventilation Openings.
Figure 4 - Chase Top Flashing
1" Noncombustible
Spacer
Chase Top
Chase Facia
Figure 5- 10' Rule
NONCHASE INSTALLATION
1. Slip on the proper pitch roof flashing
and mount the storm collar above it.
Caulk the top of the storm collar where
it contacts the outer chimney pipe.
2. Mount the round top termination and
secure it with 3 sheet metal screws to
the outer chimney pipe.
2" Collar
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com
107458-01
Rev. B
07/02
107458 01
NOT A UPC
Telescoping Top
Tab
TM
6"