En-1
CAUTION!
This mark indicates procedures which, if improperly performed,
might possibly result in personal harm to the user, or damage to
property.
Read carefully all security information before use or install the air conditioner.
Do not attempt to install the air conditioner or a part of the air conditioner by yourself.
This unit must be installed by qualified personnel with a capacity certificate for handling
refrigerant fluids. Refer to regulation and laws in use on installation place.
Th
e installation must be carried out in compliance with regulations in force
in the place
of installation and the installation instructions of the manufacturer.
This unit is part of a set constituting an air conditioner. It must not be installed alone or
with non-authorized by the manufacturer.
Always use a separate power supply line protected by a circuit breaker operating on all
wires with a distance between contact of 3mm for this unit.
The unit must be correctly grounded and the supply line must be equipped with a
differential breaker in order to protect the persons.
The units are not explosion proof and therefore should not be installed in explosive
atmosphere.
Never touch electrical components immediately after the power supply has been turned
off. Electric shock may occur. After turning off the power, always wait 5 minutes before
touching electrical components.
This unit contains no user-serviceable parts. Always consult authorized service
personnel to repairs.
When moving, consult authorized service personnel for disconnection and installation of
the unit.
2. ABOUT THE UNIT
2.1. Precautions for using the R410A refrigerant
WARNING
• Do notintroduceanysubstance other than the prescribed refrigerant into the
refrigeration cycle.
If air enters the refrigeration cycle, the pressure in the refrigeration cycle will become
abnormally high and cause the piping to rupture.
• Ifthereisarefrigerantleakage,makesurethatitdoesnotexceedtheconcentration
limit.
If a refrigerant leakage exceeds the concentration limit, it can lead to accidents such
as oxygen starvation.
• Do nottouch refrigerant thathas leaked fromthe refrigerant pipe connections or
other area. Touching the refrigerant directly can cause frostbite.
• If a refrigerant leakage occurs during operation, immediately vacate the premises
and thoroughly ventilate the area.
Iftherefrigerantcomesincontactwithaame,itproducesatoxicgas.
2.2. Special tool for R410A
WARNING
• To install a unit that uses the R410Arefrigerant, use dedicated toolsand piping
materialsthathavebeenmanufacturedspecicallyforR410Ause.
BecausethepressureoftheR410Arefrigerantisapproximately1.6timeshigherthan
the R22, failure to use dedicated piping material or improper installation can cause
rupture or injury.
Furthermore, it can cause serious accidents such as water leakage, electric shock, or
re.
Tool name Contents of change
Gauge manifold
•Pressureishugeandcannotbemeasuredwithaconventional
gauge. To prevent erroneous mixing of other refrigerants, the
diameter of each port has been changed.
It is recommended to use a gauge manifold with a high
pressuredisplayrange–0.1to5.3MPaandalowpressure
displayrange–0.1to3.8MPa.
Charging hose
•Toincreasepressureresistance,thehosematerialandbase
size were changed.
Vacuum pump
• Aconventionalvacuumpumpcanbeusedbyinstallinga
vacuum pump adapter.
Gas leakage
detector
•SpecialgasleakagedetectorforHFCrefrigerantR410A.
1. SAFETY PRECAUTIONS
• BesuretoreadthisManualthoroughlybeforeinstallation.
• ThewarningsandprecautionsindicatedinthisManualcontainimportantinformation
pertaining to your safety. Be sure to observe them.
• HandthisManual,togetherwiththeOperatingManualtothecustomer.
Request the customer to keep them on hand for future use, such as for relocating or
repairing the unit.
WARNING!
This mark indicates procedures which, if improperly performed,
might lead to the death or serious injury of the user.
• Requestyourdealeroraprofessionalinstallertoinstalltheunitinaccordancewith
thisManual.
An improperly installed unit can cause serious accidents such as water leakage,
electricshock,orre.
IftheunitisinstalledindisregardoftheinstructionsintheInstallationManual,itwill
void the manufacturer’s warranty.
• DonotturnONthepoweruntilallworkhasbeencompleted.
Turning ON the power before thework is completed can cause serious accidents
suchaselectricshockorre.
• Ifrefrigerantleakswhileworkisbeingcarriedout,ventilatethearea.
Iftherefrigerantcomesincontactwithaame,itproducesatoxicgas.
• Installationworkmustbeperformedinaccordancewithnationalwiringstandardsby
authorized personnel only.
• ExceptforEMERGENCY, neverturn offmainas wellassub breakerof theindoor
units during operation. It will cause compressor failure as well as water leakage.
First, stop the indoor unit by operating the control unit, converter or external input
device and then cut the breaker.
Makesuretooperatethroughthecontrolunit,converterorexternalinputdevice.
When the breaker is designed, locate it at a place where the users cannot start and
stop in the daily work.
INSTALLATION MANUAL
PARTNO.9374815173-04
INDOORUNIT(DuctType)
Contents
1. SAFETYPRECAUTIONS ..........................................................................................1
2. ABOUTTHEUNIT
2.1.PrecautionsforusingtheR410Arefrigerant .......................................................1
2.2.SpecialtoolforR410A ........................................................................................1
2.3. Accessories ........................................................................................................2
2.4.Optionalparts .....................................................................................................2
3. INSTALLATIONWORK
3.1.Selectinganinstallationlocation ........................................................................2
3.2A.Installationdimensions(Ceilingconcealedtype) .............................................3
3.2B.
Installationdimensions(Wallmountedtype/Floorstandingconcealedtype) ...3
3.3A.Installationtheunit(Ceilingconcealedtype) ....................................................3
3.3B.Installtheunit(Wallmountedtype/Floorstandingconcealedtype) ................5
4.
PIPEINSTALLATION
4.1.Selectingthepipematerial .................................................................................6
4.2.Piperequirement ................................................................................................7
4.3.Flareconnection(Pipeconnection) ....................................................................7
4.4.Installingheatinsulation .....................................................................................7
5. INSTALLINGDRAINPIPES
5.1A.Installingdrainpipes(Ceilingconcealedtype) .................................................8
5.1B.Installingdrainpipes(Wallmountedtype/Floorstandingconcealedtype) .............8
5.2. Install the drain pipe ...........................................................................................8
6. ELECTRICALWIRING
6.1.Wiringsystemdiagram .....................................................................................11
6.2.Connectioncablepreparation ........................................................................... 11
6.3.Connectionofwiring .........................................................................................11
7. REMOTECONTROLLERSETTING
7.1.Installingtheremotecontroller .........................................................................12
7.2.Settingthedipswitches ....................................................................................12
7.3.Functionsetting ................................................................................................13
7.4.Jumperwiresetting ..........................................................................................14
7.5.Specialinstallationmethods .............................................................................15
8. TESTRUN ...............................................................................................................15
9. OPTIONALPARTS
9.1.Wiredremotecontroller(Simpleremotecontroller) ..........................................16
9.2.Externalinputandexternaloutput ....................................................................16
9.3.Remotesensor(Optionalparts) .......................................................................16
9.4.IRReceiverUnit(Optionalparts) ......................................................................16
9.5.Autolouvergrille(Optionalparts) .....................................................................17
9.6.Optionalpartscablebinding .............................................................................17
10. CUSTOMERGUIDANCE ........................................................................................17
11. ERRORCODES ......................................................................................................18
9374815173-04_IM.indb 1 9/21/2011 1:45:04 PM