CMA ML36s User guide

Type
User guide
BAROMETER/ALTIMETERML36S
USERSGUIDE
CENTRE FOR MICROCOMPUTER APPLICATIONS
http://www.cma-science.nl
2|ML36sBarometer/AltimeterUser’sGuide
Shortdescription
TheBarometer/AltimeterML36smeasuresatmos phericpressurein therangeof300
hPato1,100hPa andcalculatestherespectivealtitudeinmetersassumingthatthe
average pressure exerted at sea level by the atmosphere is 1013.25 hPa (1
atmosphere).
The sensing element of the sensor is mounted inside the sensor housing.
The
sensor’s electronics has an automatic internal temperature compensation to
minimizetheeffectofambienttemperaturechangesonthedata.
The pressure sensor is fairly durable but it is designed only for use with non
corrosive,nonionicworkinggassessuchasair,drygasesandthelike.Donot
getit
wet.
TheBarometer/AltimeterisanI2Cdigitalsensor,whichgivescalibratedvaluesofthe
measured quantity. This sensor can only be connected to special interfaces that
supportI2C digitalsensorslikethe CMA MoLab interface.The sensorcable needed
toconnectthesensortoan interfaceisnotsupplied
withthesensor(sensorcables
aresuppliedwithinterfaces).
Sensorspecifications
The Barometer/Altimeter ML36s is a digital sensor that converts the measured
barometric pressure value to a digital value via 19bit analogtodigital conversion.
The resolution of the sensor is ± 0.01 hPa. The maximal sampling frequency of the
sensoris10Hz(samplespersecond).
Thealtitudeiscalculatedbasedonthefollowingformula:
Altitude=44,300*(1(p/p
0
)^(1/5.255))
Where p is the measured barometric pressure, and p
0
is the sea level standard
atmospheric pressure, which is 1,013.25hPa.
Practicalinformation
Allowtheoutsideairtoeasilyflowontothesensorelement.
Ifyouusethesensorinaclosedandpurelyventilatedroom,thesensorcangive
incorrectmeasurements.
Themaximumpressurethatthissensorcantolerateis1,100hPa.
Donotusethesensorin
ahotairflow.
Donotallowwateroranyliquidscomeintothesensor.
ML36sBarometer/AltimeterUser’sGuide |3
Collectingdata
This Barometer/Altimeter works only with specific interfaces. The sensor will be
automatically detected when connected to such an interface. For detailed
information about measurements with sensors consult the User Manuals of the
interfaceandtheCoach6software.
Calibration
The Barometer is supplied with a factory calibration in hPa. The Altimeter is
calibrated in meters, which values are calculated based on conversion of the
measuredpressureassuming1atmosphere(1013.25hPa)of pressureatsealevel.In
that way the sensor gives relative rather than absolute values of altitude. If
the
altitudeofyourmeasurementlocationisknown,valuescanbyadjustedbyusingthe
SettovalueoptionintheCoach6program.
Note:ThevalueforBarometricpressurereportedbyairportsandweatherstationsis
usuallygivenforthepressureatsealeveli.e.pr essureafterithasbeenadjustedtoits
equivalent at sea level. The valueobtained by this sensorwill be the pressure at its
currentlocation.
Suggestedexperiments
TheBarometer/Altimetercanbeusedinvariousexperimentssuchas:
Measurementsoftheairpressureoveralongerperiodoftime(weatherstudies).
Measurementsofthepressurein
liquidsbyconnectingthesensortoa
tube,whichissubmergedina
solution.
Measurementsofpressure
differencesbetweendifferent
floors
ofbuildings.
Altitudeinvestigations.
Figure1.Explorethepressureinsideanempty,
sealed, plastic bottle, before and after
squeezingthebottle.
4|ML36sBarometer/AltimeterUser’sGuide
TechnicalSpecifications
Sensorkind
Digital
onsensordigitalconversion
(19bitsresolution,communicationviaI2C)
Measuringrange Barometricpressure:300hPa..1100hPa
Calculatedrange Altitude:‐1000..9000m
Resolution ±0.01hPa
±0.25m
Uncertainty(accuracy)
Typical±1.0hPaat0to65,Max.±3.0hPa
Readingtime
Typical100ms
Maximalsamplingrate 10Hz
Dimensions Sensorhousing:37x18x16mm
Connection 5pinsminijackplug
Warranty:
The Barometer/Altimeter ML36s is warranted to be free from defects in materials
andworkmanshipforaperiodof12monthsfromthedateofpurchaseprovidedthat
ithasbeenusedundernormallaboratoryconditions.Thiswarrantydoesnotapplyif
thesensorhasbeendamagedbyaccidentormisuse.
Note: Thisproductistobeusedforeducationalpurposesonly.Itisnotappropriate
forindustrial,medical,research,orcommercialapplications.
Rev. 17/11/2011