Segal S 4778 Operating instructions

Type
Operating instructions

This manual is also suitable for

Please read the instructions carefully. Installation of this product should be attempted only by individuals skilled in the use
of the tools and equipment necessary for installation. Protect yourself and all persons and property during installation. If you
have any doubt concerning your competence or expertise, consult a qualified expert to perform the installation. Segal Lock
Company assumes no responsibility or obligation for the failure of an architect, contractor, installer, or building owner to
comply with all applicable laws, building codes and requirements and adequate safety precautions.
THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES IN THESE INSTRUCTIONS
This type of warning note is to indicate that
failure to follow the indicated instructions may
result in severe injury or death.
This type of warning note is used to indicate that
failure to follow the indicated instructions may
result in failure of or damage to the product and
may cause serious injury.
This type of warning note is used to indicate that
failure to follow the indicated instructions may
result in failure of or damage to the product.
Window / Child Guard Installation Instructions
BEFORE PROCEEDING, READ THE INSTRUCTIONS FULLY!
IMPORTANT SAFETY NOTES
Meets New York City Department of
Health Requirements,
Approval Code - HDWG #04-09-2010
Before installation, contact your local building code department or fire department for specific
codes related to this installation.
Make sure that your window frame is in good condition, and can accept the fasteners used in
this installation.
Use only the approved fasteners supplied with this product.
Fasteners should always be firmly anchored to a solid stud or window frame material for
maximum safety. Never anchor fasteners to decorative molding.
Always use the provided stops or “L” brackets to limit the inside sash from opening more than
4" higher than the top horizontal member. (This is a building code requirement. )
This window guard is intended to protect against potential window falls by children age 10 &
under.
Window guards are designed to be a deterrent to accidental window falls. This product is not
intended as a substitute for proper adult supervision.
This egress model is equipped with a release mechanism for emergency access, and it should
only be opened in case of an emergency or if conducting a test on the release mechanism.
Test the release mechanism once a month to ensure proper operation.
All household members 10 years of age and older should be instructed on the operation of the
release mechanism in case of an emergency.
Window guards are not meant for, and should never be used as protection against intruders.
Tools Required for Installation:
Tape Measure
Screwdriver
Drill Motor
1/8” or 9/64” Twist Drill
Parts Included:
Window Guard, 1 Hardware Pack
(10 Screws, 1 Ball Lock Pin,
2 ‘L’ Brackets, Instructions)
Make sure that the size of your window does
not exceed the stated size range that can be
found on your window guard product label.
Be sure there is no more than a 4 inch
opening anywhere in the guarded area.
Installing Outside Window Frame
1. Position window guard assembly outside window frame. Mount with the hinges and labels facing you. Determine
hinge location, (RH or LH) depending on the swing desired. (figure 1) Note: Leave enough space between the
guard and window so that normal operation of window is not restricted.
FIGURE 1
2. Fasten the hinge side of guard with one standoff tube (or mounts) to window frame using the three screws
provided. Keep the guard level vertically with a bubble level. Screws must be fastened into a solid stud
or frame. (figure 2) Note: steel framed windows, pre-drill with a 9/64" drill bit. Attach with 5/16" slotted
screwdriver. Do not tighten until final adjustment.
FIGURE 2 - TUBE
FIGURE 2 - MOUNTS
7. Position 2 window stop brackets with the holes placed against the sash track and the
stop resting on the top of the sash. Mark the position of the bracket holes on the sash
track.
8. Remove the brackets and pre-drill the holes for the four fasteners.
9. Fasten the window stop brackets in position. raise the sash to the window stops and verify that the gap is at
4" or less. (figure 5)
FIGURE 5
FIGURE 4
6 Place inside sash in a position so that the measurement from the bottom of the sash to
the top of The highest horizontal tube is 4" or less.
You Must Install Window Stops (applies to
double hung windows only)
This is a building code requirement.
If the open space from the BOTTOM of the FULLY OPENED WINDOW to the TOP of the
HIGHEST HORIZONTAL Window Guard tube exceeds FOUR (4) INCHES:
FIGURE 3 - TUBE
3. Attach vertical lock tube and standoff tube (or mounts) to opposite side of
window. Insure standoff tube (or mounts) is level with hinge side of window
guard and attach with one-way screws provided. (figure 3) Do not tighten
until final adjustment.
4. Check lock tube alignment with window guard. Close window guard and insert
lock pin. Adjust standoff tube (or mounts) up or down for proper fit of reten
tion pin. Tighten standoff tube (or mounts) and window guard screws. After
installation, test guard for proper quick release operation. (figure 4)
5. Raise the inside sash to its maximum height and measure from the bottom of
the sash to the top of the highest horizontal tube. If the measurement exceeds
4", you must use the provided window stops.If the measurement is 4" or less,
skip: Window Stop steps 6-9.
FIGURE 3 - MOUNTS
1. Hook finger in split ring (1) and pull away from retention pin assembly in order to remove keeper pin from assembly.
2. Grasp tab (2) and pull off the end of the retention pin (3).
3. Grasp keeper wire (4) and pull retention pin (3) from window guard assembly.
Guard retention pin release mechanism should be operated once
a month to ensure proper operation. All household members 10
years of age and older should be instructed on the operation of
the release mechanism.
Operating The Guard Retention Pin
1
1
2
2
3
3
4
4
© 2017 Segal Lock Company
26950 San Bernardino Ave., Redlands, CA 92374
1-800-255-3505 • Fax 1-800-437-7405
INS-WIN-EGRESS-R1