Danfoss WS503BP User guide

Type
User guide

This manual is also suitable for

Technical Information
Danfoss Telematics Solutions
WS503/WS503-BP Remote Solution
powersolutions.danfoss.com
Revision history Table of revisions
Date Changed Rev
June 2016 Update 0103
March 2016 Engineering Tomorrow 0102
March 2016 First Edition 0101
Technical Information
WS503/WS503-BP Remote Solution
2 |
©
Danfoss | June 2016 BC00000362en-US0103
About this Manual
About this manual............................................................................................................................................................................5
Device elements
Device information.......................................................................................................................................................................... 6
Type label............................................................................................................................................................................................7
Intended use...................................................................................................................................................................................... 8
WS family of telematics units.......................................................................................................................................................9
Service and support...................................................................................................................................................................... 10
Product conformity
WS503 / WS503-BP........................................................................................................................................................................11
Compliance with CE.................................................................................................................................................................11
Compliance with E1.................................................................................................................................................................11
Compliance with FCC..............................................................................................................................................................11
PLUS+1
®
Compliant..................................................................................................................................................................11
Safety information
General information......................................................................................................................................................................12
Safety advice....................................................................................................................................................................................12
General......................................................................................................................................................................................... 12
Health care..................................................................................................................................................................................12
Air traffic.......................................................................................................................................................................................13
Explosives....................................................................................................................................................................................13
Antennas......................................................................................................................................................................................13
Electronic equipment..............................................................................................................................................................13
Avoidance of property damage................................................................................................................................................13
FCC notice.........................................................................................................................................................................................14
Warranty and liability....................................................................................................................................................................15
Device functions
Available models & functions....................................................................................................................................................16
Operating modes...........................................................................................................................................................................16
Real time mode......................................................................................................................................................................... 16
Data logging / File-transfer mode......................................................................................................................................16
Wireless solutions.......................................................................................................................................................................... 16
Supported frequency bands:................................................................................................................................................17
Supported transmission rates:.............................................................................................................................................17
GNSS (Global Navigation Satellite System)...........................................................................................................................17
Input/output functions (I/O)......................................................................................................................................................17
MCU, RTC and external memory...............................................................................................................................................18
CAN Interface...................................................................................................................................................................................18
3-axis accelerometer.....................................................................................................................................................................19
Interface for micro-SD card........................................................................................................................................................ 19
Connectors
Main connector...............................................................................................................................................................................20
12-pin M12 CAN/power connector....................................................................................................................................20
Mobile radio connector............................................................................................................................................................... 21
GNSS connector..............................................................................................................................................................................21
microSD memory card................................................................................................................................................................. 22
USB port.............................................................................................................................................................................................22
Indicator elements
CAN1/CAN2 LED States................................................................................................................................................................23
ON LED states..................................................................................................................................................................................23
Mobile Radio LED states.............................................................................................................................................................. 24
GNSS LED States.............................................................................................................................................................................24
LEDs on connection with USB................................................................................................................................................... 24
Power Management..................................................................................................................................................................... 25
Local Geofence in the WS device............................................................................................................................................. 26
Technical Information
WS503/WS503-BP Remote Solution
Contents
©
Danfoss | June 2016 BC00000362en-US0103 | 3
Firmware update
Firmware update............................................................................................................................................................................27
WS503/WS503-BP Technical Data
Mechanical data............................................................................................................................................................................. 28
Electrical data.................................................................................................................................................................................. 28
Interface / Protocols / Certifications........................................................................................................................................28
Additional features........................................................................................................................................................................29
SIM card details...............................................................................................................................................................................29
Changing the SIM card
Changing the SIM card.................................................................................................................................................................30
Inserting a microSD memory card
Inserting a microSD memory card...........................................................................................................................................31
Connecting to DTS server........................................................................................................................................................... 31
Troubleshooting
Troubleshooting.............................................................................................................................................................................32
Problem with connection to DTS portal................................................................................................................................33
Required information..............................................................................................................................................................33
Tests
EMC tests...........................................................................................................................................................................................35
Electrical loads.................................................................................................................................................................................35
Temperature / climate tests.......................................................................................................................................................35
Shock / vibration tests..................................................................................................................................................................36
Packaging and transport
Packaging and transport.............................................................................................................................................................37
Disposal
European Union..............................................................................................................................................................................38
Technical drawings
WS503/WS503-BP.......................................................................................................................................................................... 39
Mounting
Mounting the unit..........................................................................................................................................................................40
Direct Bolting from the side.......................................................................................................................................................40
Direct bolting flat...........................................................................................................................................................................41
Technical Information
WS503/WS503-BP Remote Solution
Contents
4 |
©
Danfoss | June 2016 BC00000362en-US0103
About this manual
This document is part of the product and provides important information on the intended use, safety,
installation and operation of the device(s) described below. The manual is intended for qualified
technicians and electricians with advanced knowledge in electrical engineering and fieldbus systems,
allowing them to estimate the risks and hazards of operating the device and to integrate it into systems
with components of other manufacturers.
The qualified personnel must know the contents of this manual and have access to it at all times.
Technical Information
WS503/WS503-BP Remote Solution
About this Manual
©
Danfoss | June 2016 BC00000362en-US0103 | 5
This chapter gives an overview of the device elements and functions and also describes the intended use.
It further lists the available device variants and the product certifications.
Device information
The device element WS503/WS503-BP is shown in the figure below:
WS503/WS503-BP
1. Housing
2. USB port
3. 12 pin connector
4. Mobile radio antenna port
5. GNSS antenna port
6. Fixing holes
7. Fixing slots
8. GNSS LED
9. Mobile radio LED
10. Power Supply LED
11. CAN1 LED
12. CAN2 LED
13. Housing screws
14. Mounting point for rail mounting kit
15. Type label
Technical Information
WS503/WS503-BP Remote Solution
Device elements
6 |
©
Danfoss | June 2016 BC00000362en-US0103
Type label
The WS503/WS503-BP type label is located at the side of the enclosure and provides the following
information:
Type label
Device name and type
Product number
Power supply
Serial Number
International Mobile Station Equipment Identity (IMEI) number
IMEI in data matrix code
HW version
FCC-ID
E1 ID
Hot Surface EN60950
CE Mark
Country of Origin
Disposal requirements
Traceability code in data matrix code
W
Warning
The device’s type label contains important information.
Do not remove the type label.
Solvents can destroy the imprint
Do not contact the type label with any solvent-containing substance.
Technical Information
WS503/WS503-BP Remote Solution
Device elements
©
Danfoss | June 2016 BC00000362en-US0103 | 7
Intended use
W
Warning
Danger due to possibly deficient data transmission WS503/WS503-BP operates using radio signals and
cellular networks and is not authorized for use in safety-related applications.
Insufficient mobile radio network availability, interference, failure or malfunction of the device may lead
to faulty data transmission. Because of this, data transmission cannot be guaranteed at all times and
under all conditions.
Do not operate the device in machines and applications where life depends on the proper (fault free)
operation of this device.
Never rely solely on wireless device for essential communications.
Do not use this device in safety-related applications. This device operates using radio signals and is
not approved for use in safety-related applications.
This device is designed to be used in systems which must be checked for conformity with legal
requirements prior to placing into operation.
The device must only be put into operation by qualified technicians and electricians with advanced
knowledge of electrical engineering and fieldbus systems. The integrator of this device is responsible
to check and comply with regional directives and requirements.
The device can be used in environments that require protection class IP65. , i.e. protected against
contact as well as ingress of dust and against water jets against the enclosure (tested under defined
conditions of pressure and time).
IP 65 protection is only ensured if all connectors are plugged in or covered with suitable protection
caps:
Before exposing the device to dust and water, plug in all connectors.
Do not immerse the device in water or other liquids.
In the case of the USB port, protection class IP65 is also guaranteed if no plug is connected. The
protection cap included in the supply package protects the socket from soiling.
The OEM of a machine or vehicle in which PLUS+1
®
or other electronic controls are installed has the full
responsibility for all consequences that may occur.
Danfoss has no responsibility for any consequences (direct or indirect) caused by failures or
malfunctions.
Danfoss has no responsibility for any accidents caused by incorrectly mounted or maintained
equipment.
Danfoss does not assume any responsibility for PLUS+1
®
products being incorrectly applied or the
system being programmed in a manner that jeopardizes safety.
All safety critical systems shall include an emergency stop to switch off the main supply voltage for
the outputs of the electronic control system. All safety critical components shall be installed in such a
way that the main supply voltage can be switched off at any time. The emergency stop must be easily
accessible to the operator.
A system FMEA should be performed on all applications.
WS503/WS503-BP interfaces are designed for transmitting data that is available within a CAN network via
GSM/GPRS, additionally via EDGE/3G/HSDPA/HSUPA.
The interfaces are suitable for use in mobile and stationary systems for industry, small business area, and
in agricultural and forestry machinery. They feature an easy-to-install aluminum enclosure which can be
bolted to a panel or mounted to a DIN rail TS35.
Technical Information
WS503/WS503-BP Remote Solution
Device elements
8 |
©
Danfoss | June 2016 BC00000362en-US0103
WS family of telematics units
The WS Remote Solutions it’s a family of telematics devices:
Code description
Code Description
WS Wireless Solutions
A Communication and functionalities
B Country
C Options
A - Communication and functionalities
Code Description
40 Wireless CAN interface for data transmission via GSM/GPRS/EDGE and UMTS/HSDPA + GPS tracking
50 Wireless CAN interface for data transmission via GSM/GPRS/EDGE and UMTS/HSDPA + GPS tracking +
Local I/O + Serial Port
B - Country
Code Description
3 Worldwide
C - Options
Code Description
BP Internal Battery
J Japan radio modem
Example; WS503-BP
Available Models
WS503/WS503-BP are available with various options. The field B of the name designate the different
variants for country. The field A of the name designates the presence of GPS and other extra
functionalities. The field C of the name designates the device options.
You can find this name extension on the type label on the WS unit.
The tables below list the part numbers of the devices covered in this manual.
Device Descriptions Part number
WS503 CONTROL, WS503 (UMTS) w/GPS 11163199
WS503-BP CONTROL, WS503-BP (UMTS) w/GPS w/BP 11163200
Cables and antennas
Accessories
Product
number
Antenna GSM/GPS
ANT GSM QB UMTS GPS K 3M0 FME-F SMA-M FA
11149644
Power I/O cord set
M12 5pin socket / open - 2m cable
11163203
Technical Information
WS503/WS503-BP Remote Solution
Device elements
©
Danfoss | June 2016 BC00000362en-US0103 | 9
WS kits
WS503 are also available as a Kit encompassing the following components:
Device Descriptions Part number
WS503 Kit WS503 11168247
ANT GSM QB UMTS GPS K 3M0 FME-F SMA-M FA
CAN-Cable M12 5-pol /open 2m cable
WS503-BP Kit WS503-BP 11168248
ANT GSM QB UMTS GPS K 3M0 FME-F SMA-M FA
CAN-Cable M12 12-pol /open 2m cable
On the Danfoss website, you will find documentation and the WS System Tools: various software tools for
configuring and deploying the WS device.
Software
WS System Tools Product information
WS Configurator Download the program from:
http://powersolutions.danfoss.com/solutions/telematics/
WS FW Programmer
Service and support
The most recent driver, firmware, tools and documentation versions are available for download from the
website.
For further information see our website: http://powersolutions.danfoss.com/solutions/telematics/
or contact our support team: email [email protected]
Technical Information
WS503/WS503-BP Remote Solution
Device elements
10 |
©
Danfoss | June 2016 BC00000362en-US0103
WS503 / WS503-BP
Compliance with CE
This device complies with the directives, standards, and normative documents. Directive
2014/53/EU on Radio equipment and telecommunications terminal equipment
Directive 2004/108/EC on Electromagnetic compatibility
Immunity standard for industrial environments (EN 61000-6-2 (2006)
Emission standard for industrial environments (EN 61000-6-3 (2007)
Compliance with E1
E
1
This device has been approved by the KBA (Kraftfahrt-Bundesamt, Federal Office for Motor Traffic)
to comply with Regulation No. 10. ECE Regulation No. 10 (Revision 3, 14/08/2008) Approval No.: 10 R
- 036578
Compliance with FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. this device may not cause harmful interference
2. this device must accept any interference received, including interference that may cause
undesired operation
Contains transmitter FCC ID: XPYLISAU200
FCC Part 15/47 CFR Ch I (10-01-2010) Conducted Emission Limits
FCC Part 15/47 CFR Ch I (10-01-2010) Radiated Emission Limits regarding Part 15 of the FCC-rules
(Class B digital devices)
PLUS+1
®
Compliant
Danfoss Telematics Solutions are compliant with PLUS+1
®
System Control Platform.
Allow all PLUS+1
®
Service Tool functionalities to be executed remotely and additionally Danfoss
Telematics features are added in the Remote Interface (Machine information, signal strength,
geographical position linked to Google Maps, CAN Status, Safety mechanism).
Technical Information
WS503/WS503-BP Remote Solution
Product conformity
©
Danfoss | June 2016 BC00000362en-US0103 | 11
In this chapter, you will find important information on how to avoid life-threatening situations and
injuries and how to prevent product damage.
General information
These instructions are part of the device.
They contain text and illustrations for the correct handling of the module and must be read before
installation or use.
Before deploying the device described in this document, read the entire manual including all safety
information.
Non-observance of the notes, operation that is not in accordance with use as prescribed below, wrong
installation or handling can result in serious harm concerning the safety of people and plant.
Keep this manual for future use and make all information available to anyone deploying the device, even
after installation.
Tampering with the device can lead to considerable risks for the safety of people and plant. It is not
permitted and leads to an exclusion of any liability and warranty claims.
The device must be installed, connected and put into operation by a qualified electrician.
In the event of malfunctions or uncertainties, please contact the manufacturer.
This device is designed to be used in systems which must be checked for conformity with legal
requirements prior to placing into operation. The integrator of this device is responsible to check and
comply with regional directives and requirements.
Safety advice
General
Danger due to possibly deficient data transmission.
WS unit operates using radio signals and cellular networks and is not authorized for use in safety-related
applications.
Deficient network coverage, failure or malfunction of the device may lead to deficient data transmission.
Because of this, connection cannot be guaranteed at all times under all conditions.
Do not operate the device in machines and applications where life depends on the proper operation
of this piece of equipment.
Never rely solely upon any wireless device for essential communications.
Health care
Danger of interference caused by RF energy.
Medical equipment may be sensitive to RF energy.
When in a hospital or other health care facility, observe the restrictions on the use of cellular
communication equipment.
Switch WS unit off, if instructed to do so by the guidelines posted in sensitive areas.
The operation of cardiac pacemakers, other implanted medical device and hearing aids can be affected
by interference from WS unit's antennas placed close to the device.
If in doubt about potential danger, contact a physician or the manufacturer of the implanted medical
device to verify that it is properly shielded.
Pacemaker patients are advised to keep WS unit and its antennas away from the pacemaker while it is
on.
Technical Information
WS503/WS503-BP Remote Solution
Safety information
12 |
©
Danfoss | June 2016 BC00000362en-US0103
Air traffic
Danger of interference caused by RF energy.
The operation of wireless appliances in an aircraft is forbidden to prevent interference with
communications systems. Failure to observe these instructions may lead to the suspension or denial of
cellular services to the offender, legal action, or both.
Switch off WS unit before boarding an aircraft.
Make sure it cannot be switched on inadvertently.
Explosives
Danger of explosion.
The device does not comply with Directive 94/9/EC and must therefore not be used in potentially
explosive areas.
Observe the applicable regulations and precautions when you are near explosive areas (i.e. petrol
stations, fuel depots, chemical plants or where blasting operations are in progress).
Do not mount the antenna in the close environment of fuel tanks, vessels with explosives and
insufficiently shielded electronic devices.
Antennas
Danger due to absorption of RF energy.
Mobile communication devices may pose a health risk when operated in the close proximity of persons.
Install the antenna(s) used for the WS unit devices to provide a separation distance of at least 20 cm /
8 inches from all persons.
Do not operate them in conjunction or co-locate them with any other antenna or transmitter.
Electronic equipment
Danger of interference caused by RF energy
WS unit receives and transmits radio frequency energy while switched on. Interference may occur if it is
used close to TV sets, radios, computers or inadequately shielded equipment.
Follow any special regulations and always switch off the WS unit wherever forbidden, or when you
suspect that it may cause interference or danger.
Avoidance of property damage
W
Warning
Before any installation of the Control system can take place, make sure the ignition lock is turned off and
the battery is disconnected. Disconnect the device externally before handling it. Also disconnect any
independently supplied output load circuits.
Connecting of Supply Voltage
The supply voltage, should be within the operating range. Connect the supply voltage to power supply.
Protect the module by using a fuse. Requisite fuse level should be 1 A, fast (F). To avoid damage to the
device, connect/disconnect the main connector only if the power supply to the device is switched off.
Connect the WS to the same power and ground as the Control system. The power supply must be
common to both the WS and the Control unit to ensure trouble free communication. Most importantly,
the ground connection, must be the same.
Do not use the chassis as the negative terminal.
Polarity reversal
Technical Information
WS503/WS503-BP Remote Solution
Safety information
©
Danfoss | June 2016 BC00000362en-US0103 | 13
The WS module is protected against power supply polarity reversal, provided an external fuse, max 1 A
(Fast) is being used. If this fuse is not used, polarity reversal can damage the unit. Do not connect the
housing to Ground externally. This will suspend the reverse voltage protection of the power supply.
W
Warning
Applying a reversed voltage in this case will destroy the supply circuits. Do not mount the housing of the
antenna to ground or this will create shortcut to ground for the housing.
IP 65 protection is only ensured if all connectors are plugged in.
Before exposing the device to dust and water, plug in all connectors.
Do not immerse the device in water or other liquids.
The maximum torque for fixing the enclosure screws is 1.5 Nm.
When opening/closing the enclosure, do not exceed this value.
The device can only be repaired by the manufacturer.
Welding
Should be done before the installation of the control system. If welding has to be done afterwards,
the electrical connections on the system must be disconnected from other equipment, the negative
cable must always be disconnected from the battery before disconnecting the positive cable, the
ground wire of the welder shall be positioned as close as possible to the place of the welding and the
cables on the welding unit shall never be placed near the electrical wires of the control system.
Operation without antennas can destroy the radio modem.
Do not operate the device without antennas.
To prevent misuse immediately inform your network operator in case of loss or theft of the SIM card
or the radio modem.
FCC notice
The devices covered in the manual may only be used in mobile or stationary systems in which under
normal operating conditions the separation distance between the antenna(s) and all persons is at least 20
cm (approx. 8 inches). The antenna(s) must further not be co-located or operated in conjunction with any
antenna or transmitter.
According to FCC requirements, the antenna gain, including cable loss, must not exceed the limits of 7.3
dBi in the 850 MHz Cellular band and 12.7 dBi in the PCS 1900 MHz band (WS devices) or 7.2 dBi in the
850 MHz cellular band and 3.5 dBi in the PCS 1900 MHz band respectively (WS devices).
Compliance of WS unit devices in all final product configurations is the responsibility of the integrator.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the manufacturer could void the user's authority to operate the
equipment under FCC rules.
Technical Information
WS503/WS503-BP Remote Solution
Safety information
14 |
©
Danfoss | June 2016 BC00000362en-US0103
Warranty and liability
We assume no liability for defects caused by normal wear, external influences, and errors of installation,
operating or maintenance. This also applies if the customer itself or third parties without our approval
modify the components of our products (e.g. devices, elements or additional hardware facilities;
programs or program elements of the software).
Technical Information
WS503/WS503-BP Remote Solution
Safety information
©
Danfoss | June 2016 BC00000362en-US0103 | 15
Available models & functions
GSM/3G connector FME, male, front view
Model GNSS
Position
(GPS,
Glonass,
BeiDou)
CAN Bus
Interface
Local I/O External
USB
RS232 Internal
Battery
RTC Acceleratio
n sensor
SD Card
Interface
Real time &
data
logging
modes
WS403 Yes 1 1/0 No No No Yes Yes Yes Yes
WS403-J
*)
Yes 1 1/0 No No No Yes Yes Yes Yes
WS503 Yes 2 2/1 Yes Yes No Yes Yes Yes Yes
WS503-BP Yes 2 2/1 Yes Yes Yes Yes Yes Yes Yes
*)
WS403-J is for the Japanese market
Operating modes
WS devices can be operated in the following modes:
Real-time mode
Data Logging / File Transfer mode
Real time mode
CAN messages, are received by the device and sent via the Danfoss Web portal server to the remote PC.
On this computer there may be an analysis software which can handle the CAN messages. A bi-
directional data transfer is possible. When higher layer protocols are used, a special firmware and
software adaptation may be necessary due to the delay times caused by the GSM/3G network.
Depending on the device features, you can transmit data from the GNSS receiver and the input/output
functions and pass them on via the CAN bus. You can save all data to be transmitted to an internal,
nonvolatile memory and transmit them sequentially. Data is transmitted constantly and can be evaluated
in close to real-time. This function requires a permanent link between the device and the user software
via the DTS server. In the absence of a link to the server, data can be saved to a micro SD memory card
and transmitted at a later time (this function requires that a micro SD memory card is inserted and the
function is enabled ).
WS System Tools work correctly only when connected to CAN1 of WS devices. When connected remotely
to WS devices with PLUS+1 Service Tool it is only possible to see the ECU connected on CAN1, not CAN2.
Data logging / File-transfer mode
In this operation mode the WS unit logs specific CAN messages, GNSS position data and internal variables
according to its configuration and sends them in a special format to the DTS server. The WS devices have
an internal non-volatile memory which allows to store the files in case of a GSM/UMTS outage. When the
connection is recovered the files are sent to the server automatically. You can also save the data to an
inserted micro SD memory card. You can read off the data saved on the micro SD memory card using the
USB interface.
Wireless solutions
WS503/WS503-BP interfaces transmit data available on a CAN bus via GSM/UMTS telecommunication
services. In addition to data transmission via GSM/GPRS, the WS devices use the EDGE, 3G and HSPA
standards to reduce data transmission latency and to improve data transfer rate.
Beyond the GSM/UMTS functionality, these services allow for communication with web servers at higher
data rates. The communication is based on the TCP/IP protocol. Using these services requires a
connection to a specific Danfoss server.
Technical Information
WS503/WS503-BP Remote Solution
Device functions
16 |
©
Danfoss | June 2016 BC00000362en-US0103
Integrated into the device is a SIM card slot and the network operator SIM card, mini SIM 15x25mm or
other SIM card with adapters.
The SIM card remains internally in the housing.
Inserting the SIM card is only possible by unscrewing the housing. Furthermore, an embedded SIM is
provided which can be used on a SIM-card switching. It can only ever be either posted at the same time
the replaceable SIM card or embedded SIM in the mobile network. Switching between two SIM card
requires a restart the whole device.
The functionality depending on the ambient temperature can be assured for the maximum transfer rate
in the HSPA standard only between -38 ° C to 55 ° C.
For the frequency band cover a GSM quad-band and UMTS band six-module is used, which covers all
GSM frequency bands and the main UMTS frequency bands worldwide.
Supported frequency bands:
Supported frequency bands
- GSM/GPRS/EDGE
850 / 900 / 1800 / 1900 MHz
- UMTS/HSPA
800 / 850 / 900 / 1700 / 1900 / 2100 MHz
Supported transmission rates:
Supported transmission rates
Supported transmission rates
Upload Download
GPRS
85.6 Kbit/s 85.6 Kbit/s
EDGE
236 Kbit/s 236 Kbit/s
UMTS
384 Kbit/s 384 Kbit/s
HSDPA
- 7.2 Mbit/s
HSUPA
5.7 Mbit/s
GNSS (Global Navigation Satellite System)
The GNSS enables the devices to determine their position using the Global Positioning System. The
position data can then be transmitted via GSM/3G to the DTS portal, or made it available to the
connected CAN bus system. The device includes a GNSS receiver for determining position data: the
receiver can process signals from NAVSTAR GPS, GLONASS, and BeiDou (1561.098 MHz). It can process
data from two navigation systems simultaneously: this increases the accuracy.
The RF signal from the active GNSS receiver antenna is connected via a SMA connector at the same time,
the active antenna is supplied through this connector.
The GNSS update rate is 1Hz with accuracy up to 2.5 m horizontal (GPS/GLONASS)
Acquisition Cold starts: 27 s
Aided starts: 4 s
Reacquisition: 1 s
Sensitivity Tracking & Nav: –160 dBm1
Cold starts: –147 dBm
Hot starts: –156 dBm
Input/output functions (I/O)
WS503/WS503-BP feature an optional additional input/output function (2 analog inputs, 1 digital output).
You can use the input function for instance to log status information from devices or machines as well as
Technical Information
WS503/WS503-BP Remote Solution
Device functions
©
Danfoss | June 2016 BC00000362en-US0103 | 17
to directly determine and monitor switch and key states. You can send the data from the input/output
function via the CAN bus or via the mobile radio network.
One digital input:
Terminal 15, ignition
Switching threshold: 4 VDC (> 6 V high, < 2.3 V low)
Input resistance: ≥10 kOhm
Surge-proof up to 36 VDC
Reverse voltage protection up to -36 VDC
Wake-up from sleep mode capability
Ground free mounting of housing and antenna
Two analog inputs:
Measurement range: 0 Vdc to 10 Vdc
Input resistance: ≥10 kOhm
Resolution: 12 bit
Sampling rate: 10 Hz
Surge-proof up to 36 Vdc
Reverse voltage protection up to -36 Vdc
Accuracy: 1 % of the measurement range end value (at 25 °C)
One digital output:
VCC / terminal 30 switches 6 Vdc … 32 Vdc
max. output current: 500 mA
max. switch frequency: 10 Hz
Surge-proof up to 36 Vdc
Reverse voltage protection up to -36 Vdc
MCU, RTC and external memory
The device has a 32 bit microcontroller ARM Cortex M4.
can be clocked up to 168MHz
extensive peripheral 1MB NOR flash as code memory
192KB SRAM for data storage and a real-time clock, which is buffered by a super capacitor (backup
time> 48h @ 25 °C ).
Synchronization: GNSS/DTS portal Accuracy: +2.5 s/day
in addition, the unit is equipped with various external memories:
SRAM, 512KB volatile memory, connection via 16-bit data bus access time <= 45ns, optionally
buffered super capacitor (backup time> 48h @ 25 °C)
Serial FRAM, 16KB of non-volatile, cyclic writable memory for storing variables (e.g. operating hours
counter), 10 ^ 12 write cycles
Serial NOR Flash, 32 MB of non-volatile memory for storing configurations and place of logging data,
10 ^ 5 write cycles.
The dimensioning the memory size allows sufficient reserves to implement additional firmware features
at a later date.
CAN Interface
WS503/WS503-BP features two CAN interfaces. Communication through various CAN protocols such as
CANopen, J1939, is possible.
The CAN interface meets the specification CAN 2.0 A/B protocol and the physical layer according to ISO
11898-2 high-speed up to 1 Mbit/s.
Support for CAN-FD is not available.
Technical Information
WS503/WS503-BP Remote Solution
Device functions
18 |
©
Danfoss | June 2016 BC00000362en-US0103
The CAN interface is operational only when power supply is energized.
3-axis accelerometer
The device has a 3-axis accelerometer that can measure continuous acceleration values in the normal
fashion:
Measuring range > = ± 16g
Resolution > = 10 bit
sampling rate > = 10Hz
tolerance < = 2% of full-scale value (@ 25 °C)
The acceleration sensors register and evaluate accelerations in the X, Y, and Z axes, and send them via the
CAN bus.
The axis reference versus are showed in the following image:
Interface for micro-SD card
The micro-SD card interface remains internally in the housing.
Inserting the micro-SD card is only possible by unscrewing the housing.
The micro SD card is connected via SDIO to the MCU. There are both micro-SD and microSDHC cards.
Technical Information
WS503/WS503-BP Remote Solution
Device functions
©
Danfoss | June 2016 BC00000362en-US0103 | 19
WS503/WS503-BP is equipped with the following connectors:
1x Main connector (CAN Bus, I/O, RS232)
1x mobile radio antenna connector
1x GNSS antenna connector
1xUSB interface
1xmicroSD interface for microSD memory card (internal)
1xSIM card (internal)
Main connector
The main connector serves for:
connecting the WS device to the CAN bus network
supplying the WS device with power
local Inputs / Output
RS232 port
Therefore, WS503/WS503-BP has to be connected to the CAN bus network in order to operate.
W
Warning
Do not connect the housing to Ground externally. This will suspend the reverse voltage protection of
the power supply. Applying a reversed voltage in this case will destroy the supply circuits.
To avoid damage to the device, connect/disconnect the main connector only if the power supply to
the device is switched off.
To maximize the performance of the GPS receiver, mount the GPS antenna in a place where it is level
with the local geographic horizon and has full view of the sky above. If you are using separate
GSM/3G and GPS antennas, mounting them at least 2 meters away from each other will also help to
improve the GPS performance.
12-pin M12 CAN/power connector
The table and drawing below show the pin assignment of the 12-pin M12 connector. The colors stated in
the table below are the conductor colors of the cable listed in the section Accessories and provided in the
WS Kit.
CAN/power connector 12-pin M12, male, A-coded, front view
Pin Designation Color Description
1 Ground Brown Power supply
2 VCC 6 … 32 V DC Blue Power supply
3 n.c. (not connected) White
Input (ignition signal)
4 CAN-High Green CAN
5 CAN-Low Pink CAN
6 Analog input 1 Yellow I/O Input
7 Analog Input 2 Black I/O Input
8 RS232 TXD Gray Output
9 Digital Output Red I/O Output
10 RS232 RXD Violet Input
Technical Information
WS503/WS503-BP Remote Solution
Connectors
20 |
©
Danfoss | June 2016 BC00000362en-US0103
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Danfoss WS503BP User guide

Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI