Intel 220T User manual

Category
Network media converters
Type
User manual
Intel Express
220T Stackable Hub
Quick Start
English
Français
Italiano
Deutsch
Español
Install the Hub
Connect
the Devices
Check the
Connections
Quick Start
• Remove the hub and parts from the box.
• Use the enclosed brackets if you plan to
mount the hub in a rack.
• Install the Express 220T Stackable Hub in
a rack or on a shelf.
• Plug in the power cord.
• Check the port LEDs to confirm the link
status.
A solid LED (on the left) indicates a valid
link.
All ports are set to automatically detect the
speed of the device connected to it.
• Connect PCs and print servers to the hub
with a straight-through cable.
• Use a crossover cable to connect a hub to a
switch.
• Use only CAT 5 UTP to connect 100Mbps
devices. To connect 10Mbps devices use
CAT 3, 4, or 5 UTP.
Left (Orange/Green)
Orange = 10Mbps
Green = 100Mbps
Solid = Link
Blink = Activity
Right (Yellow)
Solid = Disabled
Blink = Wrong speed
Colls 10Mbps
Colls 100Mbps
RPS
Power
Intel Express 220T
Stackable Hub
Bridged
Managed
Enable/Disable
Bridging
Status
Class
I
Left (Orange/Green)
Orange = 10Mbps
Green = 100Mbps
Solid = Link
Blink = Activity
Right (Yellow)
Solid = Disabled
Blink = Wrong speed
12345678 9101112
Rack: Use the four
small screws to attach
the brackets to the hub.
Shelf: Peel off the protective
backing and attach the rubber
feet to the hub.
3
1
2
100
100
100
Hub Switch
Hub Print Server
Hub PC/Server
crossover
straight-through
From To
English
1
Add Additional
Modules
Bridge the 10Mbps and
100Mbps Segments
Stack the Hubs
The hub’s internal bridge is active by
default and bridges the 10Mbps and
100Mbps segments (collision domains).
• If you are bridging the 10Mbps and
100Mbps segments externally (for
example, through a 10/100 switch) be sure
to turn off the hub’s internal bridge.
• If you have a stack of hubs, any bridging
button on any hub in that stack will enable
or disable bridging for the entire stack.
• Unplug the hubs.
• Use an Intel Cascade Cable to connect the
hubs. Hubs can be stacked up to eight
high (mixed 12- or 24-port).
• When properly connected, the entire stack
will act as a single repeater with two
segments (10Mbps and 100Mbps). The
top hub in a stack will be numbered hub 1.
Never daisy-chain hubs
running at 100Mbps with UTP
cable. Doing so violates the
IEEE 802.3u Fast Ethernet
standard for Class I hubs.
• The 12-port 220T can accept additional
modules (refer to the User Guide).
• Use the modules to manage a stack,
connect to devices at full-duplex, or to
extend the network to another building
or beyond 100 meters.
Optional Information
Colls 10Mbps
Colls 100Mbps
RPS
Power
Intel Express 220T
Stackable Hub
Bridged
Managed
Enable/Disable
Bridging
Status
bridging
button
Esc
Management
with RMON
Module
Reset
Xmt Link
Rcv Coll
TX RX
Fiber Module
Change
duplex
Half-duplex
Full-duplex
Change
duplex
Ethernet Module
MDI
MDI-X
Auto-negotiate
Full-duplex
Half-duplex
Change
duplex
Auto-negotiate
100 Mbps
10 Mbps
Coll
or
Management Module for
Express Hubs.
Fiber Module for
Express Hubs.
Ethernet Module for
Express Hubs.
4
6
5
Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz
Redundant Power Supply (RPS)
Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz
Redundant Power Supply (RPS)
Hub 1
Hub 2
Intel Cascade Cable
(Product Code EE200CC)
Hub Defaults
Segment 1=10Mbps
Segment 2=100Mbps
Bridging=active
The Bridged LED
lights when internal
bridging is active for
the hub or stack
EnglishEnglish
2
Chinese
3
3
1
2
Colls 10Mbps
Colls 100Mbps
RPS
Power
Intel Express 220T
Stackable Hub
Bridged
Managed
Enable/Disable
Bridging
Status
Class
I
Left (Orange/Green)
Orange = 10Mbps
Green = 100Mbps
Solid = Link
Blink = Activity
Right (Yellow)
Solid = Disabled
Blink = Wrong speed
12345678 9101112
100
100
100
 !"
 !
 !
 !
 !"#$%&'()
 !"#$%&'()*+,-
 !"#$
 !"#$%&=bñéêÉëë=OOMq
 !"#$
 !"#
 !=iba !"#$%&
iba= !"#$%&'()*+

 !"#$%&'()*+,
 !"#$%&
 !"#$%=m`= !"#
 !"#$
 !"#$%&'()*+,-

 =R==rqm= !"#$%
=NMMjÄéë= !"#$%&'
=NMjÄéë= !"#$=PQ
=R==rqm=
 !"#
 !"#$%
 !"#
 !"#$%
 !"#$%&'()*

 =m`L
 = !"


 !"L
=Z=NMjÄéë
=Z=NMMjÄéë
 !=Z=
=Z=
 !"#
 !=Z=
=Z= !"


220QS_CS.pm6 3/31/98, 3:26 PM2
ChineseChinese
4
4
6
5
Colls 10Mbps
Colls 100Mbps
RPS
Power
Intel Express 220T
Stackable Hub
Bridged
Managed
Enable/Disable
Bridging
Status
Esc
Management
with RMON
Module
Reset
Xmt Link
Rcv Coll
TX RX
Fiber Module
Change
duplex
Half-duplex
Full-duplex
Change
duplex
Ethernet Module
MDI
MDI-X
Auto-negotiate
Full-duplex
Half-duplex
Change
duplex
Auto-negotiate
100 Mbps
10 Mbps
Coll
Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz
Redundant Power Supply (RPS)
Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz
Redundant Power Supply (RPS)
 !"
=10Mbps==100Mbps

 !"
 !"#$% !&'()*+
 !"=NMjÄéë==NMMjÄéë=
 !"#$
 !"#$=NMjÄéë==NMMjÄéë
 !"#$%&=NMLNMM=
 !"#$%&'()*+,

 !"#$%&'()&'*+,
 !"#$%&'()*+,-
 !"#$%&'(
 !"#$%&'(
=fåíÉä= !"#$%&'(
 !"#$%&'()*+,-
NO==OQ=
 !"#$%&'()*+,-
 !"NMjÄéë==NMMjÄéë
 !"#$%&'()!'*+
 !=N
=rqm= !"#$%&
 !"#$%=NMMjÄéë=
 !"#=f= !"=fbbb
UMOKPì=c~ëí= !"#
NO==OOMq= !"#$%&'
 !"#$%&'()
 !"#$%&'()*+ *
 !"#$%&'()*+,-
 !=NMM= !
 !"
 !
=bñéêÉëë=
 !"#
=bñéêÉëë=
 !"#
=bñéêÉëë= !
 !"#
fåíÉä= !
 !"#
 =NZNMjÄéë
 =OZNMMjÄéë
Z
 !"#$%&
 !"#$%&
 !"#$%&

 =N
 =O
 !"=bbOMM``

220QS_CS.pm6 3/31/98, 3:28 PM3
5
3
1
2
Colls 10Mbps
Colls 100Mbps
RPS
Power
Intel Express 220T
Stackable Hub
Bridged
Managed
Enable/Disable
Bridging
Status
Class
I
Left (Orange/Green)
Orange = 10Mbps
Green = 100Mbps
Solid = Link
Blink = Activity
Right (Yellow)
Solid = Disabled
Blink = Wrong speed
12345678 9101112
100
100
100
=
 =
 =
=
 != = = !"K
 == !"= =
= !"#K
 = =bñéêÉëë=OOMq
pí~Åâ~ÄäÉ=eìÄ= !"#K
= = != !"K
=iba= !==
 !"#K
iba=EF====
== = !"K
= == = =
 = != !"=
= !K
 = != !=m`=
= = = !"#K
 = != != =
 = !"#K
NMMjÄéë== = !"
`^q=R=rqm= !"#K
NMjÄéë= = !"=`^q=PI
QI==R=rqm= !"#K
=E LF
== =Z=NMjÄéë
===Z=NMMjÄéë
====Z=
== =Z=
 =EF
====Z==
== =Z==
W===
 = !=
 = =
 !K
W= !=
I= !=
= !"#K
 ============
 ====== =
 =========m`L


 ===============

220QS_KO.pm6 3/31/98, 3:55 PM4
6
6

4
6
5
Colls 10Mbps
Colls 100Mbps
RPS
Power
Intel Express 220T
Stackable Hub
Bridged
Managed
Enable/Disable
Bridging
Status
Esc
Management
with RMON
Module
Reset
Xmt Link
Rcv Coll
TX RX
Fiber Module
Change
duplex
Half-duplex
Full-duplex
Change
duplex
Ethernet Module
MDI
MDI-X
Auto-negotiate
Full-duplex
Half-duplex
Change
duplex
Auto-negotiate
100 Mbps
10 Mbps
Coll
Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz
Redundant Power Supply (RPS)
Input
100-120VAC/2.5A
200-240VAC/1.5A
47Hz-63Hz
Redundant Power Supply (RPS)
==
10Mbps  !"
100Mbps= !"
 != !"#
=
 = = != !"
 !"I=NMjÄéë= !"
NMMjÄéë= !=E=F
 !"K
NMjÄéë= !"=NMMjÄéë=
 = = !==E
I=NMLNMM= !=FI=
= = != !K
 = ==I= =
== = ==
= !=== =
 !K
 = = !K
fåíÉä=`~ëÅ~ÇÉ= != !
 = !"#K= ==U
 = == !=E
NOJ==OQJFK
 = !I== =
 !=ENMjÄéë==NMMjÄéë=
F==== = =
= K= === =
N= = !"K
NMMjÄéë= !=
rqm= != !=
= = != !K
==f= ==fbbb
UMOKPì=c~ëí= ==
= !=
NOJ=OOMq== =
= !=E = =FK
=I= = !==
I== !"=NMM= !
 = == !=
I= = !"#K
==


= =
K
= =
K
= =
K
=N
=O
fåíÉä=`~ëÅ~ÇÉ=
E==bbOMM``F
=
 !=NZNMjÄéë
 !=OZNMMjÄéë
 =Z
 = =
==
 ==
==
iba==
 K
220QS_KO.pm6 3/31/98, 3:58 PM5
694479-001
Copyright © 1998,
Intel Corporation.
All rights reserved.
*Other product and corporate names
may be trademarks of other companies
and are used only for explanation and to
the owners’ benefit, without intent to
infringe.
Intel Corporation assumes no
responsibility for errors or omissions in
this manual. Nor does Intel make any
commitment to update the information
contained herein.
Intel Corporation
5200 NE Elam Young Parkway
Hillsboro OR 97124-6497
Customer Support:
http://support.intel.com
First Edition May 1998
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Intel 220T User manual

Category
Network media converters
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI